DarkSide: Difference between revisions
(One intermediate revision by the same user not shown) | |||
Line 66: | Line 66: | ||
* main switch: | * main switch: | ||
** ports 0,1,2,3 - vlan300, speed 1gige - 4 fiber downlinks to chimney 1gige | ** ports 0,1,2,3 - vlan300, speed 1gige - 4 fiber downlinks to chimney 1gige infrastructure switches, 192.168.2.x | ||
** port 4 - vlan300, speed 1gige - uplink to midas server, 192.168.2.x | ** port 4 - vlan300, speed 1gige - uplink to midas server, 192.168.2.x | ||
** port 5 - vlan300, speed 1gige - spare, 192.168.2.x | ** port 5 - vlan300, speed 1gige - spare, 192.168.2.x | ||
Line 75: | Line 75: | ||
** ports 14..49 - vlan1, speed 10gige - FEP-TSP network, 192.168.4.x | ** ports 14..49 - vlan1, speed 10gige - FEP-TSP network, 192.168.4.x | ||
* chimney | * chimney 1gige infrastructure switch (4x): | ||
** all ports 192.168.2.x | ** all ports 192.168.2.x | ||
** 1gige fiber uplink to main switch | ** 1gige fiber uplink to main switch | ||
* chimney VX switch (4x): | * chimney 10gige VX switch (4x): | ||
** all ports 192.168.0.x | ** all ports 192.168.0.x | ||
** 10gige fiber uplink to main switch | ** 10gige fiber uplink to main switch | ||
Line 91: | Line 91: | ||
* network 192.168.2.x is the DAQ infrastructure network | * network 192.168.2.x is the DAQ infrastructure network | ||
** dhcp/dns/ntp from dsdaqgw | ** dhcp/dns/ntp from dsdaqgw | ||
** | ** main switch vlan300 | ||
*** | *** 1gige RJ45 uplink to dsdaqgw | ||
*** 1gige RJ45 to juniper-private management interface | *** 1gige RJ45 to juniper-private management interface ("do not connect!") | ||
*** | *** 1gige fiber to per-rack "orange switch" (4x) | ||
** per- | ** per-chimney infrastructure switch ("orange switch") (4x) | ||
*** RJ45 SCP (slow control PC) | *** RJ45 SCP (slow control PC) | ||
*** RJ45 CDU | *** RJ45 CDU | ||
*** RJ45 VME P.S. | *** RJ45 VME P.S. | ||
*** RJ45 "gray switch" management interface | *** RJ45 VX switch ("gray switch") management interface | ||
*** total: | *** SFP fiber 1gige uplink to main switch | ||
*** total: 4 RJ45 ports + 1 SFP fiber uplink | |||
* network 192.168.0.x is the VX network: | * network 192.168.0.x is the VX network: | ||
** | ** dhcp/dns/ntp from dsdaqgw | ||
** | ** main switch vlan400 | ||
** "gray switch" | *** 10gige DAC uplink to dsdaqgw | ||
*** 4x "green vx", | *** 10gige fiber downlink to per-chimney VX switch (4x) | ||
*** 9x "red vx", | ** per-chimney VX switch ("gray switch") (4x) | ||
*** 4x "green vx", 10gige DAC | |||
*** 9x "red vx", 10gige DAC | |||
*** 6x 10gige fiber to fep machines | *** 6x 10gige fiber to fep machines | ||
*** 10gige fiber uplink to main switch | |||
*** total: 19 SFP ports | *** total: 19 SFP ports | ||
*** management interface RJ45 to | *** management interface RJ45 to infrastructure switch ("orange switch") | ||
* network 192.168.4.x is the FEP network | * network 192.168.4.x is the FEP and TSP network | ||
** dhcp/dns/ntp from dsdaqgw (dnsmasq, chronyd) | ** dhcp/dns/ntp from dsdaqgw (dnsmasq, chronyd) | ||
** | ** main switch vlan1 | ||
** 10gige SFP to the | ** 10gige SFP to the dsdaqgw | ||
** 4x6 = 24x | ** 4x6 = 24x 10gige DAC to FEPs | ||
** ?x 10gige DAC to TSPs | |||
** | |||
Latest revision as of 18:03, 18 November 2024
DarkSide DAQ
The DarkSide-20k data acquisition is to operate in a triggerless mode. This means that every photodetection unit (PDU) produces a data flow independently from its neighbours and no global decision is invoked for requesting data. Also, the experiment is composed of several thousand channels that need to be processed together in order to apply data filtering and/or data reduction before the final data recording to a storage device. The analysis time for a such large number of channels requires substantial computer processing power. The Time Slice concept is to divide the acquisition time into segments and submit them individually to a pool of Time Slice Processors (TSP). Based on the duration of the time segment, the analysis performance, and the processing power of the TSPs, an adequate number of them will be able to handle the continuous data stream from all the detectors.
THIS FIG shows the overall DarkSide-20K DAQ architecture. At the bottom, a global Clock is distributed to four waveform digitizers located on the top of the detector. The readout of those WFDs is done by a collection of frontend processors (FEPs) which in turn connect in turn to a second cluster of processors (TSPs, see below).
The Time Slice concept is to segment the data-taking period across all the acquisition modules. The collected data for each segment is then presented to a TSP for processing. Once the analysis is complete, the TSP informs an independent application of its availability to process a new Time Slice.
Physics events happening across two consecutive Time slices is to be managed properly as the TSPs will not have access to the previous time slice. This is addressed by duplicating a fraction of the time slice to the next TSP. This overlapping time is to ensure that this extended segment covers the possible boundary events. It corresponds in our case to the maximum electron drift time within the TPC (∼5ms). The default time slice duration is 1 second, meaning that we will have 0.5% duplicate analyzed events in that overlap window.
THIS FIG shows the run time segmentation (abscissa). Each segment is processed by a different TSP. The total number of TSPs must be greater than the average time (in seconds) it takes to process 1 second of data. The large number of PDUs (Photo Detector Units, ie. frontend electronics) or channels implies that multiple digitizers are at work. Therefore the time segmentation mechanism requires the transmission of a Time Slice Marker (TSM) to all the digitizers in order to ensure a proper segment assembly based on the Time Slice number. The readout of the individual waveform digitizer (WFD) is performed by a dedicated processor Front-End Processor (FEP). For similar processing power issues as for the TSPs, the FEP will handle a subset of WFDs (2), meaning that in our case, 24 FEPs will collect all the digitizer data. Each FEP will have to read out, filter, and assemble the data fragments from the WFDs covering the predefined time slice duration.
The management of the transmission of the data segment to individual TSPs is left to the Pool Manager (PM) application. Its role is to receive ”idle” notification from any TSPs (once the previous time slice analysis has been completed) and broadcast to all the FEPs the destination address for the upcoming segment to the next available idle TSP.
In order to ensure a proper Time Slice synchronization, a "Time Slice Marker" (TSM) is inserted at the WFDs level under the form of a bit. The frequency of the TSM defines the Time Slice Duration. For each TSM trigger, a WFD event is always produced and therefore will appear in the data stream at the FEP collector. The TSM event is shown in the figure below in orange. While the WFD acquisition is asynchronous due to the randomness of the event generation at the WFD level, the TSM is meant to sort the data across a given FEP based on the Time Slice number. An extra intermediate stage of data filtering or data reduction can be implemented between the Acquisition thread and the sorting thread. The Time Slice sorted output data buffer combining all the WFD of this FEP is then available to the Transfer thread pushing the requested Time Slice data to the Time Slice Processor.
Links
- https://owl.phy.queensu.ca/DS20k/TWiki/bin/view/Main/DaqPage
- https://dsvslice.triumf.ca
- DS-DM VME DS-DM board DarkSide GDM and CDM
- https://daq00.triumf.ca/elog-ds/DS-DAQ/
Dsvslice ver 1
- main computer: dsvslice
- network 142.90.x.x - connection to TRIUMF
- network 192.168.0.x - 1gige VX network
- vx01..vx04, gdm, cdm, vmeps01, etc
- network 192.168.1.x - 10gige DSFE and DSTS network
- dsfe01..04 - frontend processors
- dsts01..05 - timeslice processors
Dsvslice ver 2
Second implementation of the vertical slice is intended to be as close as possible to the final network topology shown on the chart above.
Implemented are:
- VX network 192.168.0.x
- infrastructure network 192.168.2.x
- combined FEP and TSP network 192.168.4.x
Computer interfaces
- main computer: dasdaqgw.triumf.ca, network links:
- eno1: 1gige RJ45: 142.90.x.x TRIUMF
- enp5s0: 1gige RJ45: 192.168.2.x infrastructure network
- enp1s0f0: 10gige SFP DAC: 192.168.0.x VX network
- enp1s0f1: 10gige SFP DAC: 192.168.4.x FEP and TSP network
- FEP computer, network links:
- enp1s0f0: 10gige SFP DAC: 192.168.4.x FEP and TSP network, nfsroot to dsdaqgw
- enp1s0f1: 10gige SFP DAC: 192.168.0.x VX network
- eno1: 1gige RJ45: not used
- eno2: 1gige RJ45: not used
- TSP computer, network links:
- 10gige SFP: 192.168.4.x FEP and TSP network
Switch interfaces
- main switch:
- ports 0,1,2,3 - vlan300, speed 1gige - 4 fiber downlinks to chimney 1gige infrastructure switches, 192.168.2.x
- port 4 - vlan300, speed 1gige - uplink to midas server, 192.168.2.x
- port 5 - vlan300, speed 1gige - spare, 192.168.2.x
- ports 6,7 - vlan1, speed 1gige - spare, 192.168.4.x
- ports 8,9,10,11 - vlan400, speed 10gige - 4 fiber downlinks to chimney 10gige VX switches, 192.168.0.x
- port 12 - vlan400, speed 10gige - uplink to midas server, 192.168.0.x
- port 13 - vlan400, speed 10gige - spare, 192.168.0.x
- ports 14..49 - vlan1, speed 10gige - FEP-TSP network, 192.168.4.x
- chimney 1gige infrastructure switch (4x):
- all ports 192.168.2.x
- 1gige fiber uplink to main switch
- chimney 10gige VX switch (4x):
- all ports 192.168.0.x
- 10gige fiber uplink to main switch
- 6x 10gige fiber uplink to FEP machines
- 12x 10gige DAC downlink to VX2745 digitizers
- 2x 1gige RJ45 downlinks to CDMs
- 1gige RJ45 downlink to GDM (one chimney)
Networks
- network 192.168.2.x is the DAQ infrastructure network
- dhcp/dns/ntp from dsdaqgw
- main switch vlan300
- 1gige RJ45 uplink to dsdaqgw
- 1gige RJ45 to juniper-private management interface ("do not connect!")
- 1gige fiber to per-rack "orange switch" (4x)
- per-chimney infrastructure switch ("orange switch") (4x)
- RJ45 SCP (slow control PC)
- RJ45 CDU
- RJ45 VME P.S.
- RJ45 VX switch ("gray switch") management interface
- SFP fiber 1gige uplink to main switch
- total: 4 RJ45 ports + 1 SFP fiber uplink
- network 192.168.0.x is the VX network:
- dhcp/dns/ntp from dsdaqgw
- main switch vlan400
- 10gige DAC uplink to dsdaqgw
- 10gige fiber downlink to per-chimney VX switch (4x)
- per-chimney VX switch ("gray switch") (4x)
- 4x "green vx", 10gige DAC
- 9x "red vx", 10gige DAC
- 6x 10gige fiber to fep machines
- 10gige fiber uplink to main switch
- total: 19 SFP ports
- management interface RJ45 to infrastructure switch ("orange switch")
- network 192.168.4.x is the FEP and TSP network
- dhcp/dns/ntp from dsdaqgw (dnsmasq, chronyd)
- main switch vlan1
- 10gige SFP to the dsdaqgw
- 4x6 = 24x 10gige DAC to FEPs
- ?x 10gige DAC to TSPs