BNMR: Difference between revisions

From DaqWiki
Jump to navigation Jump to search
en>Suz
No edit summary
en>Suz
mNo edit summary
Line 176: Line 176:
* logs the data
* logs the data
* monitors the experiment
* monitors the experiment
{{Category:BNMR}}

Revision as of 14:25, 27 April 2016

BNMR Experiments at TRIUMF

Purpose

These pages describe the Data Acquisition System (DAQ) for the BetaNMR (BNMR) and BetaNQR (BNQR) experiments at TRIUMF

Introduction

The Data Acquisition System is based on the MIDAS data acquisition package.

There are two separate experimental setups :

  • bnmr running on the BNMR high-voltage platform
  • bnqr running on the BNQR high-voltage platform

Each experimental setup has its own #Hardware Components (i.e. a VME crate containing DAQ modules). Each runs as a separate MIDAS experiment named bnmr and bnqr. DAQ software specific to these experiments (MIDAS clients e.g. frontends) run the experiments - see #Software Components.

Beam Control

The main TRIUMF EPICS Control System is used to control the beam, which can be switched to either experiment's beamline. There are two Beam Modes that the experiments can be run in:

single channel mode
where the beam is sent to one channel only, either BNMR or BNQR. Only one of the DAQ systems bnmr or bnqr is active.
dual channel mode
where the beam is switched between the two channels BNMR and BNQR at regular intervals. Both DAQ systems bnmr and bnqr are active.

Environment

For both experiments, two types of environment are defined (cf MUSR experiments):

  • Integral (Type 1)
  • Time Differential or TD (Type 2)
  • Combination of the above two types


Experimental Modes

A number of different experimental modes are defined for each of Type 1 (Integral) and Type 2 (TD) #Environments. These allow different experimental modes to be run (e.g. Frequency scan, Na Cell scan). The modes used in recent years are shown in a brighter colour. These modes correspond to different programs downloaded into the PPG (i.e. to different pulse sequences) so are also known as PPG Modes. To understand what each experimental mode does, consult the appropriate timing diagram listed below.

Table 1 INTEGRAL and TIME DIFFERENTIAL Experimental (PPG) Modes
Table 1a: Type 1 Integral Modes
Mode Name Run Parameters Timing Figure
Scalers 10 Same as 1f
1a 1a 1a
1b 1b 1b
Freq 1f 1f
NaCell 1n 1n
Laser 1d 1d
Camp 1c 1c
Fast * 1g Not available
LCR ** 1j Not available
*Combination of Modes 20 and 1f
**Combination of Modes 20 and 1c
spacer


Table 1b: Type 2 Differential Modes
Mode Name Run Parameters Timing Figure
SLR 20 20
2a 2a 2a
2b 2b 2b
2c 2c 2c
2d 2d 2d
2e 2e 2e
this
is
a
spacer
a


Hardware Components

DAQ hardware components for each DAQ system (BNMR/BNQR) include the following VME modules:

Table 2: Hardware Modules for each Experiment
Module Description Manual VME Base Address BNMR BNQR
SIS3801 version E multichannel scaler A SIS3801 0x2800 yes yes
SIS3801 version E multichannel scaler B 0x1800 yes no
PPG (Pulseblaster) Pulse Programmable module PPG
Spincore Pulseblaster
0x8000 yes yes
PSM Pol Synthesizer module (RF) PSM / PSMII
AD9857 Quadrature
Digital Upconverter
0xC00000 no yes
PSMII Pol Synthesizer module II (RF) 0xC00000 yes no
MVME162 68040 board, cpu runs CAMP (VxWorks) bnmrvw polvw
VMIC cpu runs frontend (Linux) lxbnmr lxbnqr


The names of the VMIC running the frontend and MVME162 (the CAMP host) for bnmr and bnqr experiments are shown in Table 2 above.

Software Components

The DAQ system is based on the MIDAS package. Data acquisition software to run the bnmr and bnqr experiments has been written to run under MIDAS. This includes the frontend, custom logger etc. This software is mostly common to both experiments (differences between the two experiments are handled with ifdefs).

The experiment is controlled using the MIDAS webserver (mhttpd). Due to the large number of experimental parameters required, Midas custom pages have been written for the experimenters to control and monitor their experiment.

The custom logger (mdarc/midbnmr) saves the data into MUSR MUD format files, and the MUSR CAMP slow control system is used for slow controls. Analysis is done by physica.

The DAQ software components are started by the script start-all and stopped by the script kill-all.

The main software components of the bnmr and bnqr experiments are

Table 3: Software Components
Component Purpose
frontend (runs on VMIC) set up, operate and read hardware modules
rf_config check PPG parameters, download program to PPG
mdarc custom data logger saves data in MUD format
midbnmr converts MIDAS format saved data files to save in MUD format
mheader sends out CAMP and EPICS slow-control data to be saved in the MUD data file
fe_epics sends experimental data to EPICS (can be read by control-room)
perlscripts various perlscripts control changing experimental mode, checking and maintaining run numbering, etc.
autorun automatic run controller
lcrplot plots experimental data
physica analyse data, reads MUD format files

Each of these components is described in more detail here.


DAQ Summary

The VMIC front end computer runs the frontend code which
  • controls PSM,PPG, VMEIO
  • acquires data from SIS MCS module(s), builds histograms
  • acquires data from CAMP, EPICS
  • sends the data out into the data buffer
The host computer (isdaq01)
  • run all other software components
  • starts/stops runs
  • acquires the data from the data buffer
  • logs the data
  • monitors the experiment

Main Contents for BNMR/BNQR Experiment