= Links =
== Introduction ==
<div style="column-count:3;-moz-column-count:3;-webkit-column-count:3">
This page describes the different '''Experimental Modes''' (also known as '''PPG Modes''') available for the  {{bnmqr|join=and}} experiments. Not all modes are supported for both {{bnmqr|join=and}} experiments. New modes are added as needed.
* [[BNMR]]
*
* [[BNMR: Adding a new mode|Adding a new mode]]
* [[BNMR: Getting Started|Getting Started]]
</div>


==Introduction ==
There are two separate concepts that use similar naming schemes (e.g. 1f, 20) - the timing of pulses issued by the PPG and the name of the overall experimental mode. The overall mode determines both which timing scheme is run, as well as which hardware is scanned during the run (e.g. RF frequency, Na cell voltage). Multiple experimental modes may use the same PPG timing scheme (e.g. modes 1c, 1d, 1e, 1n use the PPG timing scheme called 1n).
This page describes the different experimental modes (also known as PPG modes) available for the experiments. New modes are added as needed. Refer also to the timing diagram for the mode (several modes may share the same timing diagram). See full list of modes [[BNMR#Experimental (PPG) Modes|here]].
 
All modes are of Type 1 (c.f. I-musr), type 2 (c.f. TD-Musr), or a combination of both types. All Type 1 modes have a designation starting with "1", e.g. "1a","1f". Similarly all type 2 modes start with a "2", e.g. "2a", "2e".  Some modes also have a name, e.g. Mode "10" is called "Scalers", Mode "20" is called "SLR".
All modes are of Type 1 (c.f. I-musr), type 2 (c.f. TD-Musr), or a combination of both types. All Type 1 modes have a designation starting with "1", e.g. "1a","1f". Similarly all type 2 modes start with a "2", e.g. "2a", "2e".  Some modes also have a name, e.g. Mode "10" is called "Scalers", Mode "20" is called "SLR".  The more commonly used modes are described under [[#Experimental Mode Parameters]].


Note that the data are saved in different histograms depending on whether the mode is Type 1 or Type 2. The combination modes are given a type designation (1 or 2) according to how their histograms are saved.
Note that the data are saved in different histograms depending on whether the mode is Type 1 or Type 2. The combination modes are given a type designation (1 or 2) according to how their histograms are saved.
Line 21: Line 15:
In Type 2 modes,  the scaler data for each PPG Cycle is accumulated in the histogram memory in the frontend. The RF may be turned on for part of the cycle. The histogram memory is only cleared at the begin-of-run, and the histograms are accumulated within the frontend. Periodically, the data is read out by{{Client|name=mdarc}}, and saved directly into MUD format.   
In Type 2 modes,  the scaler data for each PPG Cycle is accumulated in the histogram memory in the frontend. The RF may be turned on for part of the cycle. The histogram memory is only cleared at the begin-of-run, and the histograms are accumulated within the frontend. Periodically, the data is read out by{{Client|name=mdarc}}, and saved directly into MUD format.   


== Selecting an Experimental (PPG) Mode ==
== Full list of modes ==
The available PPG Modes are displayed and [[BNMR: Starting a run#Select Experimental (PPG) Mode|selected]] using the  {{bnmqr|join=or}} custom status page. Each mode has its own set of run parameters, which are displayed on the Parameters Page (see [[BNMR: Starting a run#Review the run parameters|review the run parameters]]). Some run parameters are common between the modes (e.g. helicity). The run parameters for the more common experimental modes are described in [[#Experimental Mode Parameters]] below.
[[BNMR#Experimental_modes|Click here to see a full list of experimental modes]], or use the [[BNMR:_Custom_Modes_page|modes webpage]] for more detailed information about each mode.
 
== Changing the mode ==
The available experimental modes are displayed on the [[BNMR:_Custom_Modes_page|modes webpage]], and the mode can be changed using the the [[BNMR:_Custom_Modes_page|modes webpage]], the [[BNMR:_Custom_Settings_page|settings webpage]], or the [[BNMR:_Mode_changer|mode changer python script]]. Each mode has its own set of run parameters, which are displayed on the [[BNMR:_Custom_Settings_page|settings webpage]].
   
   
== Experimental Mode Parameters ==
== Adding a new mode ==
;NOTE:
See the [[BNMR: Adding a new mode|adding a new mode]] page.
;Not all experimental modes are supported for both experiments.
 
* Type 1 
** [[BNMR:PPG MODE 10]]
** [[BNMR:PPG MODE 1c]]
** [[BNMR:PPG MODE 1f]]
** [[BNMR:PPG MODE 1n]]
** [[BNMR:PPG MODE 1w]]
* Type 2
** [[BNMR: PPG MODE 20]]
** [[BNMR: PPG MODE 2e]]
** [[BNMR: PPG MODE 2h]]
** [[BNMR: PPG MODE 2s]]
[[Category:BNMR]]  [[Category:Experiment (PPG) Modes]]
[[Category:BNMR]]  [[Category:Experiment (PPG) Modes]]

Latest revision as of 14:03, 27 April 2022

Introduction

This page describes the different Experimental Modes (also known as PPG Modes) available for the bnmr and bnqr experiments. Not all modes are supported for both bnmr and bnqr experiments. New modes are added as needed.

There are two separate concepts that use similar naming schemes (e.g. 1f, 20) - the timing of pulses issued by the PPG and the name of the overall experimental mode. The overall mode determines both which timing scheme is run, as well as which hardware is scanned during the run (e.g. RF frequency, Na cell voltage). Multiple experimental modes may use the same PPG timing scheme (e.g. modes 1c, 1d, 1e, 1n use the PPG timing scheme called 1n).

All modes are of Type 1 (c.f. I-musr), type 2 (c.f. TD-Musr), or a combination of both types. All Type 1 modes have a designation starting with "1", e.g. "1a","1f". Similarly all type 2 modes start with a "2", e.g. "2a", "2e". Some modes also have a name, e.g. Mode "10" is called "Scalers", Mode "20" is called "SLR".

Note that the data are saved in different histograms depending on whether the mode is Type 1 or Type 2. The combination modes are given a type designation (1 or 2) according to how their histograms are saved.

Type 1 (I-MUSR)

In Type 1 modes, a variable is incremented between a maximum and a minimum value forming a "scan", which is then repeated. At each increment, one of more PPG Cycles are run, and the data are stored in histogram memory in the frontend. In this mode, the histogram data are output after each increment, and saved as MIDAS-format data by the standard MIDAS logger mlogger. The helicity may be flipped after each complete scan, or, in some modes, after each PPG Cycle. The frontend histogram memory is cleared after the data are output at each scan increment. This MIDAS-format file is then converted to MUD-format by the MIDAS client mdarc.

Type 2 (TD-MUSR)

In Type 2 modes, the scaler data for each PPG Cycle is accumulated in the histogram memory in the frontend. The RF may be turned on for part of the cycle. The histogram memory is only cleared at the begin-of-run, and the histograms are accumulated within the frontend. Periodically, the data is read out bymdarc, and saved directly into MUD format.

Full list of modes

Click here to see a full list of experimental modes, or use the modes webpage for more detailed information about each mode.

Changing the mode

The available experimental modes are displayed on the modes webpage, and the mode can be changed using the the modes webpage, the settings webpage, or the mode changer python script. Each mode has its own set of run parameters, which are displayed on the settings webpage.

Adding a new mode

See the adding a new mode page.