GSI TRB3: Difference between revisions

From DaqWiki
Jump to navigation Jump to search
Line 60: Line 60:




5) Setup the analyzer
== Doing TDC analysis ==
 
This is how we do the TDC analysis using the GSI tools:
 
A) Setup the analyzer


<pre>
<pre>
Line 69: Line 73:




6) Create the set of calibration constants for the TDC
B) Create the set of calibration constants for the TDC


<pre>
<pre>
Line 75: Line 79:
rm cal*.cal  (remove old calibration files)
rm cal*.cal  (remove old calibration files)
export CALTRIG=0; export CALMODE=-1;
export CALTRIG=0; export CALMODE=-1;
go4analysis -number 100000 -user /data/trb3_data/pulser17342111720.hld
go4analysis -number 100000 -user /data/trb3_data/pulser17342114715.hld
</pre>
</pre>


Line 83: Line 87:




7) Now analyze more events, using those calibration files
C) Now analyze more events, using those calibration files


<pre>
<pre>
rm *root
rm *root
export CALTRIG=0; export CALMODE=0;
export CALTRIG=0; export CALMODE=0;
go4analysis -number 1000000 -user /data/trb3_data/pulser17342111720.hld
go4analysis -number 1000000 -user /data/trb3_data/pulser17342114715.hld
</pre>
</pre>


Line 97: Line 101:
</pre>
</pre>


and use TBrowser() to look at the difference histogram
and use TBrowser() to look at the difference histogram.  In particular, right now we look at the histogram TDC_0100/Ch3/TDC_0100_Ch3_RisingRef which shows the difference between the two synchronized input channels.  This distribution should show a timing resolution between the hits of ~18ps if all the TDC calibration is working fine...


== Useful TRB3 commands ==
== Useful TRB3 commands ==

Revision as of 12:49, 8 December 2017

TRB3 is an FPGA-TDC board made and sold by GSI. It can achieve ~20ps timing resolution

Documentation

Main TRB documentation

Computer Setup Instructions

Currently have gotten this working on an Opensuse machine.

We setup TRB3 on a private network. So need machine with second ethernet port.

Full instructions to be written

Start-up Instructions

These are the basic instructions to initialize and take data from TRB3, using the GSI DAQ tools.

1) Start the trb3 program and initialize the TRB3

cd /home/tbr3_user/trbsoft/daqtools/users/triumf_trb171
source startup.sh

2) Start webbrowser: In new terminal, do

cd /home/tbr3_user/trbsoft/daqtools/web/
./cts_gui --noopenxterm --port=1234 --endpoint=0xc001

open webbrowser and go to

http://daq14.triumf.ca:1234/

3) Start event builder: In new terminal, do

cd trbsoft/daqtools/users/triumf_trb171/
 dabc_exe TdcEventBuilder.xml

4) Enable the readout of the channels we want.

i) Go to webpage

http://daq14.triumf.ca:1234/tdc/tdc.htm

ii) Under 'board' set it to 0100.

iii) Then click 'enable' radio button

iv) Then, under 0100 set all the channel groups to on. Should then start seeing triggers for different channels (if we have signals going into channels).

v) Finally, disable the trigger window on the same page. On the section c801 click off and make sure it says 'disabled'. If trigger window is disabled then all triggers are accepted...


Doing TDC analysis

This is how we do the TDC analysis using the GSI tools:

A) Setup the analyzer

source ~/trbsoft/trb3/trb3login 

(This needs to be run in any terminal where you want to run the go4analysis


B) Create the set of calibration constants for the TDC

cd /home/tbr3_user/trbsoft/daqtools/users/triumf_trb171
rm cal*.cal  (remove old calibration files)
export CALTRIG=0; export CALMODE=-1;
go4analysis -number 100000 -user /data/trb3_data/pulser17342114715.hld

(need to change this to use the hld file that you want to use)

The resulting calibration files are called something like cal_010X.cal


C) Now analyze more events, using those calibration files

rm *root
export CALTRIG=0; export CALMODE=0;
go4analysis -number 1000000 -user /data/trb3_data/pulser17342114715.hld

now open the resulting root file

root -l Go4AutoSave.root

and use TBrowser() to look at the difference histogram. In particular, right now we look at the histogram TDC_0100/Ch3/TDC_0100_Ch3_RisingRef which shows the difference between the two synchronized input channels. This distribution should show a timing resolution between the hits of ~18ps if all the TDC calibration is working fine...

Useful TRB3 commands

a) Get IDs for TRB3 FPGAs (1 central FPGA and 4 FPGAs for TDCs):

trb3_user@linux-klyr:~/lindner> trbcmd i 0xffff
0xc001  0xe1000006e937ac28  0x05
0x0100  0x9c000006e937a028  0x00
0x0101  0x91000006e95e8328  0x01
0x0102  0x75000006e9383128  0x02
0x0103  0xe6000006e96e5228  0x03

b) Print out raw TDCs for the events that are coming in through event builder

hldprint localhost:6789 -onlytdc 0x0100 -num 0 

c) Print out raw TDCs for events in file

hldprint //data/trb3_data/pulser17342114715.hld -onlytdc 0x0100 -num 0 

d) "Ping of death" somehow ping board to reboot it:

ping  -pc001 trb171