Magnetic Trap: Difference between revisions

From HaicuWiki
Jump to navigation Jump to search
 
(5 intermediate revisions by 2 users not shown)
Line 1: Line 1:
= General =
= General =


[[File:HAICU vector.svg|300x300px|frameless|center]]
[[File:Magnetic trap model.png|300x300px|frameless|center]]


= Experimental Setup =
= Mechanical =
 
= Electrical =
 
The Bitter magnets (top and bottom gates, booster coil, and quadrupole) are powered by dedicated high current power supplies. Since the bottom gate needs to ramp very quickly (less than 1ms), it is powered by an AE Techron 8500 amplifier ([[Equipment_Manuals#AE_Techron_8500|documentation]]), which can provide a current output proportional to a control voltage signal with a very fast and reproducible reaction time. This is a modular device, that currently contains two units capable of delivering a steady state current of 100A each for a total of 200A. In the future this will be upgraded to the full six-module unit for up to 600A gate current.
 
All other magnets are powered by Sorensen SGX10x1200 DC supplies ([[Equipment_Manuals#Sorensen_SGX10X1200|documentation]]) that are capable of delivering 1200A each. While gate and booster coils are designed for up to 400A, the quad will ideally run above 1200A eventually. For this purpose two SGX will be configured in leader-follower mode to be able to provide up to 2400A. Currently only one SGX is used per magnet.
 
= Water cooling =
 
= Magnet Control System =
 
== SGX ==
 
The Sorensen power supplies can be remotely controlled in two ways:
 
* via SCPI text commands over ethernet (also GPIB or RS232, but this is not relevant for us)
* via analog control and monitoring voltages (0-10V or 0-5V), either in '''C'''ontrolled '''C'''urrent or '''C'''ontrolled '''V'''oltage mode
 
== AE Techron 8500 ==
 
The AE Techron is quite bare bones in comparison. While it, too, can operate in '''CC''' or '''CV''' mode, it does not have any user interface. It simply generates a signal based on an analog control voltage (0-10V) and provides some monitoring voltages, proportional to actual delivered voltage and actual delivered current. Some limited diagnostic values (like amplifier temperature) are available on a separate connector.
 
== Magnet Control Box ("piBox") ==
 
Since the AE Techron needs to be controlled by analog voltage, it was decided to do the same for the SGX, to make the system easier to understand. Since timing requirements are modest (of the order of 100 microseconds) we decided to provide this control voltage from a raspberry pi with DAC extension board ("hat"). An ADC is also needed for the monitoring voltages. Originally we decided on the [[Equipment_Manuals#Waveshare_AD/DA_hat|WaveShare AD/DA board]], which combines both functionalities, but during development opted for the [[Equipment_Manuals#CONTEC_CPI-AO-1602LC|Contec CPI-AO-1602LC]] for the DAC portion, because its range of 0-10V matches the 0-10V input range of the AE Techron.
 
=== Operating principle ===
 
Sequencing and timing between devices is provided by the PPG, which accepts ''READY'', ''VETO'', and ''FINISHED'' TTL signals on its inputs, and supplies trigger TTL signals on its outputs. In order for a magnet to be ramped, this is the simple order of operations on the raspberry pi:
# a ramp is loaded into the raspberry pi. This ramp takes the shape of a list of times and current set points.
# the raspberry pi gets ''ARMED'', i.e. it monitors the GPIO pin designated its ''TRIGGER'' for a rising edge.
# the raspberry pi sets its ''READY'' pin high (this is connected to one of the ''GATE'' pins of the PPG)
# upon receiving a trigger, the pi steps through the ramp, setting the DAC output accordingly. (It does its best to follow the ramp, skipping steps if their time passed before the previous step finished.) Depending on operational modes, it keeps track of whether steps succeed/
# after finishing the ramp, ''READY'' gets set low, and if ramping was successful, ''FINISHED'' gets set high.
 
The PPG, meanwhile, is usually set up to send a sequence of trigger signals synchronized to the next external trigger (coming from the laser pulser) after being started, but only if all selected ''GATE'' inputs are high and all ''VETO'' inputs are low.
 
=== Ramp Queue ===
 
For more complex operation, the pi can hold a queue of ramps. This means it will loop through steps 1-5 for each entry in the queue, waiting for a new trigger for each.
 
=== Software details ===
 
For more details about the implementation, see the [https://gitlab.triumf.ca/haicu/magnet_control git repository] and [[Magnet Control Software]]. For the PPG (sequencer) client, see [https://gitlab.triumf.ca/haicu/ppg_client git repository], for the firmware, see [https://gitlab.triumf.ca/haicu/ppg_cb_firmware git repository]. Further documentation for both is in [[Programmable Pulse Generator (PPG)]].
 
=== Operation ===
 
= Field Characterization =


* [[Field Mapping Probe]]
* [[Field Mapping Probe]]


* [[Gate Coil Timing Measurements]]
* [[Gate Coil Timing Measurements]]

Latest revision as of 23:12, 18 November 2026

General

Magnetic trap model.png

Mechanical

Electrical

The Bitter magnets (top and bottom gates, booster coil, and quadrupole) are powered by dedicated high current power supplies. Since the bottom gate needs to ramp very quickly (less than 1ms), it is powered by an AE Techron 8500 amplifier (documentation), which can provide a current output proportional to a control voltage signal with a very fast and reproducible reaction time. This is a modular device, that currently contains two units capable of delivering a steady state current of 100A each for a total of 200A. In the future this will be upgraded to the full six-module unit for up to 600A gate current.

All other magnets are powered by Sorensen SGX10x1200 DC supplies (documentation) that are capable of delivering 1200A each. While gate and booster coils are designed for up to 400A, the quad will ideally run above 1200A eventually. For this purpose two SGX will be configured in leader-follower mode to be able to provide up to 2400A. Currently only one SGX is used per magnet.

Water cooling

Magnet Control System

SGX

The Sorensen power supplies can be remotely controlled in two ways:

  • via SCPI text commands over ethernet (also GPIB or RS232, but this is not relevant for us)
  • via analog control and monitoring voltages (0-10V or 0-5V), either in Controlled Current or Controlled Voltage mode

AE Techron 8500

The AE Techron is quite bare bones in comparison. While it, too, can operate in CC or CV mode, it does not have any user interface. It simply generates a signal based on an analog control voltage (0-10V) and provides some monitoring voltages, proportional to actual delivered voltage and actual delivered current. Some limited diagnostic values (like amplifier temperature) are available on a separate connector.

Magnet Control Box ("piBox")

Since the AE Techron needs to be controlled by analog voltage, it was decided to do the same for the SGX, to make the system easier to understand. Since timing requirements are modest (of the order of 100 microseconds) we decided to provide this control voltage from a raspberry pi with DAC extension board ("hat"). An ADC is also needed for the monitoring voltages. Originally we decided on the WaveShare AD/DA board, which combines both functionalities, but during development opted for the Contec CPI-AO-1602LC for the DAC portion, because its range of 0-10V matches the 0-10V input range of the AE Techron.

Operating principle

Sequencing and timing between devices is provided by the PPG, which accepts READY, VETO, and FINISHED TTL signals on its inputs, and supplies trigger TTL signals on its outputs. In order for a magnet to be ramped, this is the simple order of operations on the raspberry pi:

  1. a ramp is loaded into the raspberry pi. This ramp takes the shape of a list of times and current set points.
  2. the raspberry pi gets ARMED, i.e. it monitors the GPIO pin designated its TRIGGER for a rising edge.
  3. the raspberry pi sets its READY pin high (this is connected to one of the GATE pins of the PPG)
  4. upon receiving a trigger, the pi steps through the ramp, setting the DAC output accordingly. (It does its best to follow the ramp, skipping steps if their time passed before the previous step finished.) Depending on operational modes, it keeps track of whether steps succeed/
  5. after finishing the ramp, READY gets set low, and if ramping was successful, FINISHED gets set high.

The PPG, meanwhile, is usually set up to send a sequence of trigger signals synchronized to the next external trigger (coming from the laser pulser) after being started, but only if all selected GATE inputs are high and all VETO inputs are low.

Ramp Queue

For more complex operation, the pi can hold a queue of ramps. This means it will loop through steps 1-5 for each entry in the queue, waiting for a new trigger for each.

Software details

For more details about the implementation, see the git repository and Magnet Control Software. For the PPG (sequencer) client, see git repository, for the firmware, see git repository. Further documentation for both is in Programmable Pulse Generator (PPG).

Operation

Field Characterization