Magnetic Trap: Difference between revisions

From HaicuWiki
Jump to navigation Jump to search
(Starting work on magnet control documentation.)
Line 2: Line 2:


[[File:Magnetic trap model.png|300x300px|frameless|center]]
[[File:Magnetic trap model.png|300x300px|frameless|center]]
= Mechanical =
= Electrical =
The Bitter magnets (top and bottom gates, booster coil, and quadrupole) are powered by dedicated high current power supplies. Since the bottom gate needs to ramp very quickly (less than 1ms), it is powered by an AE Techron 8500 amplifier ([[Equipment_Manuals#AE_Techron_8500|documentation]]), which can provide a current output proportional to a control voltage signal with a very fast and reproducible reaction time. This is a modular device, that currently contains two units capable of delivering a steady state current of 100A each for a total of 200A. In the future this will be upgraded to the full six-module unit for up to 600A gate current.
All other magnets are powered by Sorensen SGX10x1200 DC supplies ([[Equipment_Manuals#Sorensen_SGX10X1200|documentation]]) that are capable of delivering 1200A each. While gate and booster coils are designed for up to 400A, the quad will ideally run above 1200A eventually. For this purpose two SGX will be configured in leader-follower mode to be able to provide up to 2400A. Currently only one SGX is used per magnet.
= Water cooling =
= Magnet Control System =
== SGX ==
The Sorensen power supplies can be remotely controlled in two ways:
* via SCPI text commands over ethernet (also GPIB or RS232, but this is not relevant for us)
* via analog control and monitoring voltages (0-10V or 0-5V), either in '''C'''ontrolled '''C'''urrent or '''C'''ontrolled '''V'''oltage mode
== AE Techron 8500 ==
The AE Techron is quite bare bones in comparison. While it, too, can operate in '''CC''' or '''CV''' mode, it does not have any user interface. It simply generates a signal based on an analog control voltage (0-10V) and provides some monitoring voltages, proportional to actual delivered voltage and actual delivered current. Some limited diagnostic values (like amplifier temperature) are available on a separate connector.
== Magnet Control Box ("piBox")
Since the AE Techron needs to be controlled by analog voltage, it was decided to do the same for the SGX, to make the system easier to understand. Since timing requirements are modest (of the order of 100 microseconds) we decided to provide this control voltage from a raspberry pi with DAC extension board ("hat"). An ADC is also needed for the monitoring voltages. Originally we decided on the [[Equipment_Manuals#Waveshare_AD/DA_hat|WaveShare AD/DA board]], which combines both functionalities, but during development opted for the [[Equipment_Manuals#CONTEC_CPI-AO-1602LC|Contec CPI-AO-1602LC]] for the DAC portion, because its range of 0-10V matches the 0-10V input range of the AE Techron.
[https://gitlab.triumf.ca/haicu/magnet_control magnet_control]


= Field Characterization =
= Field Characterization =

Revision as of 18:12, 5 November 2026

General

Magnetic trap model.png

Mechanical

Electrical

The Bitter magnets (top and bottom gates, booster coil, and quadrupole) are powered by dedicated high current power supplies. Since the bottom gate needs to ramp very quickly (less than 1ms), it is powered by an AE Techron 8500 amplifier (documentation), which can provide a current output proportional to a control voltage signal with a very fast and reproducible reaction time. This is a modular device, that currently contains two units capable of delivering a steady state current of 100A each for a total of 200A. In the future this will be upgraded to the full six-module unit for up to 600A gate current.

All other magnets are powered by Sorensen SGX10x1200 DC supplies (documentation) that are capable of delivering 1200A each. While gate and booster coils are designed for up to 400A, the quad will ideally run above 1200A eventually. For this purpose two SGX will be configured in leader-follower mode to be able to provide up to 2400A. Currently only one SGX is used per magnet.

Water cooling

Magnet Control System

SGX

The Sorensen power supplies can be remotely controlled in two ways:

  • via SCPI text commands over ethernet (also GPIB or RS232, but this is not relevant for us)
  • via analog control and monitoring voltages (0-10V or 0-5V), either in Controlled Current or Controlled Voltage mode

AE Techron 8500

The AE Techron is quite bare bones in comparison. While it, too, can operate in CC or CV mode, it does not have any user interface. It simply generates a signal based on an analog control voltage (0-10V) and provides some monitoring voltages, proportional to actual delivered voltage and actual delivered current. Some limited diagnostic values (like amplifier temperature) are available on a separate connector.

== Magnet Control Box ("piBox")

Since the AE Techron needs to be controlled by analog voltage, it was decided to do the same for the SGX, to make the system easier to understand. Since timing requirements are modest (of the order of 100 microseconds) we decided to provide this control voltage from a raspberry pi with DAC extension board ("hat"). An ADC is also needed for the monitoring voltages. Originally we decided on the WaveShare AD/DA board, which combines both functionalities, but during development opted for the Contec CPI-AO-1602LC for the DAC portion, because its range of 0-10V matches the 0-10V input range of the AE Techron.

magnet_control

Field Characterization