Equipment List Parameters: Difference between revisions

From MidasWiki
Jump to navigation Jump to search
No edit summary
(The midas documentation has moved to https://midas.triumf.ca/docs/)
Tag: Replaced
 
(16 intermediate revisions by 2 users not shown)
Line 1: Line 1:
== Links ==
The midas documentation has moved. The new documentation about the equipment list is in:
 
* [https://midas.triumf.ca/docs/develop/features/acquiring_data/frontends/programming/#declaring-your-equipment Declaring your equipment] on the Frontends: programming page (declaring equipment in a frontend)
[[#Equipment Name]] [[#EventID]] [[#TriggerMask]]  [[#Equipment Type]]  [[#Test1]]  [[#Buffer]]
* [https://midas.triumf.ca/docs/develop/reference/reference/odb_keys/#equipmentxxxcommon /Equipment/xxx/Common] on the ODB keys page (the equipment parameters in the ODB)
 
* [https://midas.triumf.ca/docs/develop/features/acquiring_data/slow_control/programming/#the-device-driver-list The device driver list] on the Slow control: programming page (class and device drivers for slow control equipment)
[[#Equipment Type]] [[Equipment Flags#EQ_PERIODIC|EQ_PERIODIC]] [[Equipment Flags#EQ_POLLED|EQ_POLLED]] [[Equipment Flags#EQ_INTERRUPT|EQ_INTERRUPT]] [[Equipment Flags#EQ_MULTITHREAD|Q_MULTITHREAD]] [[Equipment Flags#EQ_SLOW|EQ_SLOW]]  [[Equipment Flags#EQ_MANUAL_TRIG|EQ_MANUAL_TRIG]]  [[Equipment Flags#EQ_EB|EQ_EB]] [[Equipment Flags#EQ_FRAGMENTED|EQ_FRAGMENTED]]
 
[[#MirroredInODB]]
 
==Equipment List ==
The ''Equipment List'' is a declaration of the equipment(s) in a frontend using the ''EQUIPMENT structure'' defined in ''midas.h'' in the MIDAS package.
 
Only those fields that are needed by the frontend to define the equipments are included (see [[Example Equipment List declaration in a frontend|example]] below). The contents of these fields (or parameters) determine the properties of each equipment. Some of these parameters are copied to the ODB <span style="color: purple;">''/Equipment/<equipment-name>/Common''</span> subdirectory when the frontend is initialized.
 
Each parameter found in a frontend Equipment List is described below under [[#Explanation of Equipment List parameters|Explanation of Equipment List parameters]].
 
==Example Equipment List declaration in a frontend ==
 
 
An example of an Equipment declaration in a frontend is shown below:
 
/*-- Equipment list ------------------------------------------------*/
                            //
EQUIPMENT equipment[] = {
                            //
  {"Trigger",              /* equipment name */
    {1, 0,                  /* event ID, trigger mask */
    "SYSTEM",              /* event buffer */
    EQ_POLLED,              /* equipment type */
    LAM_SOURCE(0, 0xFFFFFF),        /* event source crate 0, all stations */
    "MIDAS",                /* format */
    TRUE,                  /* enabled */
    RO_RUNNING |            /* read only when running */
    RO_ODB,                /* and update ODB */
    100,                    /* poll for 100ms */
    0,                      /* stop run after this event limit */
    0,                      /* number of sub events */
    0,                      /* don't log history */
    "", "", "",},
    read_trigger_event,      /* readout routine */
    },
                            //
  {"Scaler",                /* equipment name */
    {2, 0,                  /* event ID, trigger mask */
    "SYSTEM",              /* event buffer */
    EQ_PERIODIC | EQ_MANUAL_TRIG,  /* equipment type */
    0,                      /* event source */
    "MIDAS",                /* format */
    TRUE,                  /* enabled */
    RO_RUNNING | RO_TRANSITIONS |  /* read when running and on transitions */
    RO_ODB,                /* and update ODB */
    10000,                  /* read every 10 sec */
    0,                      /* stop run after this event limit */
    0,                      /* number of sub events */
    0,                      /* log history */
    "", "", "",},
    read_scaler_event,      /* readout routine */
    },
                            //
  {""}
};
 
 
== Explanation of Equipment List parameters ==
===Equipment Name===
This [[#Equipment List|Equipment List Parameter]] defines the name of the equipment. Each equipment name must be unique (i.e. no two equipments in the same experiment may have the same name). The name will be the reference name of the equipment generating the event. Examples of typical Equipment Names are "Trigger","Scaler","Epics".
 
===EventID===
This [[#Equipment List|Equipment List Parameter]] defines the event ID for this equipment. Each equipment has to be associated with a  unique event ID . The event ID will be part of the event header of that particular equipment.
 
===TriggerMask===
This [[#Equipment List|Equipment List Parameter]] is active when the equipment [[#Type|Type]] is  [[#EQ_INTERRUPT|EQ_INTERRUPT]] or [[#EQ_MULTITHREAD|EQ_MULTITHREAD]]. In this case,  each equipment must be associated with a unique Trigger Mask.  The Trigger Mask can be modified dynamically by the readout routine to define a  [[subevent type]] on an event-by-event basis. This can be used to mix "physics events" (from a physics trigger) and "calibration events" (from a clock for example) in one run and identify them later. Both parameters are declared as 16-bit values. If the Trigger Mask is used in a single bit-wise mode, 16 is the maximum number of different masks available. 
 
If not active, set to 0.
 
<div id="MirroredInODB"></div>
===Buffer===
This [[#Equipment List|Equipment List Parameter]] specifies the name of the Buffer to which the event will be sent. After composition of an equipment, the Midas  [[Frontend Operation#Frontend|Frontend]] ''mfe.c''
takes over the sending of this event to the buffer (usually the SYSTEM buffer) on the back-end computer  where it may be sent to the data logger [([mlogger]]) and the [[analyser]].
 
*  If this field is left empty, (i.e. set to ""), the readout function associated with that equipment will still be performed, but the  actual event won't be sent to the buffer. Instead, that particular equipment can be mirrored in the ODB if the [[#RO_ODB|RO_ODB]] flag is turned on (see @ref  FE_RO_ODB_example "example").  The ODB is updated with a new event approximately every second. Note that this feature is generally used only for testing or monitoring, as writing large amounts of data to the ODB takes time.
* By using a buffer other than the SYSTEM buffer,  [[Event Filtering]] can be implemented.
* If using an [[Event Builder]] ( i.e. a secondary stage on the back-end to collect and assemble events coming from different buffers in order to compose a larger event) , a dedicated buffer can be specified.  In this case the [[#EQ_EB|EQ_EB]] flag must be turned on, and the events coming from the  [[Frontend Operation#Frontend|Frontend]] are called  ''fragments''.
 
 
===Type===
This [[#Equipment List|Equipment List Parameter]] specifies the type of equipment, and should be set to one of the Equipment Flags EQ_XXX selected from the [[Equipment Flags|list of valid Equipment Flags]], i.e. one of
<div style="column-count:4;-moz-column-count:4;-webkit-column-count:4">
* [[Equipment Flags#EQ_PERIODIC|EQ_PERIODIC]]
* [[Equipment Flags#EQ_POLLED|EQ_POLLED]]
* [[Equipment Flags#EQ_INTERRUPT|EQ_INTERRUPT]]
* [[Equipment Flags#EQ_MULTITHREAD|EQ_MULTITHREAD]]
* [[Equipment Flags#EQ_SLOW|EQ_SLOW]]
* [[Equipment Flags#EQ_MANUAL_TRIG|EQ_MANUAL_TRIG]]
* [[Equipment Flags#EQ_EB|EQ_EB]]
* [[Equipment Flags#EQ_FRAGMENTED|EQ_FRAGMENTED]]
</div>
 
===Source===
This [[#Equipment List|Equipment List Parameter]]  (i.e. the  interrupt or event source) is only used if the equipment [[#Type|Type]] is set to  [[Equipment Flags#EQ_INTERRUPT|EQ_INTERRUPT]] or [[Equipment Flags#EQ_MULTITHREAD|EQ_MULTITHREAD]]. The interrupt Source field is a bit-wise pattern representing the interrupt that is allowed to trigger the call to the  [[readout routine]]. The  @ref  FE_poll_or_interrupt_readout_routine "example"  shows a CAMAC or VME source for the interrupt. A MACRO (LAM_SOURCE) calculates the bit pattern from the parameters (Crate,Slot).
 
If not using an interrupt, this field is set to 1.
 
 
===Format===
This [[#Equipment List|Equipment List Parameter]] specifies the data format used for generating the event. Only [[Event Structure#MIDAS Format Event|"MIDAS"]] and  [[Event Structure#FIXED Format Event|"FIXED"]] formats are valid in the frontend. The format must agree with the way the event is composed in the equipment [[readout routine]].  It tells the system how to interpret an event when it is copied to the ODB or displayed in a user-readable form. Data in MIDAS and/or FIXED format from the frontend can be saved by the MIDAS data logger [[Mlogger|mlogger]] in a number of formats (see  [[Keys in the ODB /Logger/Channels tree #/Logger/Channels/0/Settings/Format | mlogger format]] ).
'''NOTE'''
*MIDAS or FIXED data format can be mixed at the frontend level, but <span style="color:darkcyan;">''mlogger''</span> is not able to handle this format diversity on a event-by-event basis.
: In practice, the data format (MIDAS/FIXED) should be identical throughout one equipment definition. Different equipments can, of course, have different formats in the same frontend.
* ROOT format cannot be specified in the equipment definition. To save raw data in ROOT format,  the [[#Bank definition]] must be supplied, and a conversion to ROOT format is done by the [[Keys in the ODB /Logger/Channels tree #/Logger/Channels/0/Settings/Format | data logger]] ).
* For FIXED events, the  [[Bank definition]] parameter may contain the  [[Init String]].
 
===Enabled===
This [[#Equipment List|Equipment List Parameter]] is the enable switch for the equipment. Only when enabled (i.e. TRUE) is this equipment active.
 
 
===ReadOn===
This [[#Equipment List|Equipment List Parameter]] specifies when the read-out of an event occurs or is enabled (i.e. on which transition state(s) and/or on which run state(s) respectively) by using a combination of
[[ReadOn Flags]].
<div style="column-count:5;-moz-column-count:5;-webkit-column-count:5">
* [[ReadOn Flags|RO_RUNNING]]
* [[ReadOn Flags|RO_STOPPED ]]
* [[ReadOn Flags|RO_PAUSED ]]
* [[ReadOn Flags|RO_BOR ]]
* [[ReadOn Flags|RO_EOR]]
* [[ReadOn Flags|RO_PAUSE]]
* [[ReadOn Flags|RO_RESUME ]]
* [[ReadOn Flags|RO_TRANSITIONS]]
* [[ReadOn Flags|RO_ALWAYS ]]
* RO_ODB
</div>
;NOTE : These flags can be combined with the logical OR operator,e.g. RO_RUNNING | RO_TRANSITIONS means that the event is read out when
running and additionally on all transitions.
 
===Period===
This [[#Equipment List|Equipment List Parameter]] specifies the time interval for [[Equipment Flags#EQ_PERIODIC|EQ_PERIODIC]] equipment or time out value in the case of [[Equipment Flags#EQ_POLLED|EQ_POLLED]] or [[Equipment Flags#EQ_MULTITHREAD|EQ_MULTITHREAD]] equipments (units are milliseconds).
 
===Event limit===
This [[#Equipment List|Equipment List Parameter]] specifies the number of events to be taken prior to forcing an End-of-Run  [[Run States and Transitions#transition]]. The value 0 disables this option.
 
===Number of subevents===
This [[#Equipment List|Equipment List Parameter]] enables the [[Super Event]] capability if &gt; 0 . Specifies the maximum number of sub-events in the [[Super Event]]. (Not applicable to [[Event Structure#FIXED Format Event|FIXED format]] events.)
 
===Log History===
This [[#Equipment List|Equipment List Parameter]] enables/disables the @ref  [[history system]] for that equipment. The value (positive in seconds) specifies the time interval between subsequent history events. A positive value enables history logging, in which case the event data will also be sent automatically to the ODB in the
<span style="color: purple; font-style:italic;">/equipment/<equipment-name>/variables</span> tree.
 
To disable history logging of this event, set this parameter to 0.
 
 
<div id="EventTrigger"></div> <div id="ManualTriggerMode"></div>
===Readout Routine===
This [[#Equipment List|Equipment List Parameter]]  contains the name of the user-written function to be called when the event is triggered. The name of this routine is specified by the user. This readout routine must be present in the frontend code. It will be called at an
event trigger, which will occur under one of these conditions depending on the [[Equipment List Parameters#Type|Type]] parameter.
 
;polled mode : the poll_event() routine has detected a trigger request while polling on a trigger source.
;interrupt mode : an interrupt has occurred whose source is pre-defined in the interrupt_configure() routine.
;periodic modes : trigger occurs periodically at a time interval specified by the [[Equipment List Parameters#Period|Period]] parameter.
;manual trigger mode : trigger occurs when
:: 1. the  [[manual trigger button]] is pressed on the web interface or
:: 2. a client requests an event by  @ref FE_backend_Manual_Trigger "triggering the event sending mechanism" via a RPC.
 
Click for further details of a @ref FE_poll_event "poll_event routine" and an  @ref FE_interrupt_event "interrupt routine".

Latest revision as of 22:00, 30 October 2026

The midas documentation has moved. The new documentation about the equipment list is in: