Entry  27 May 2014, Scott Oser, Suggestion, Saving ODB values in a sequencer script 
    Reply  12 Jun 2014, Stefan Ritt, Suggestion, Saving ODB values in a sequencer script 
       Reply  12 Jun 2014, Scott Oser, Suggestion, Saving ODB values in a sequencer script 
Message ID: 1008     Entry time: 12 Jun 2014     In reply to: 1007
Author: Scott Oser 
Topic: Suggestion 
Subject: Saving ODB values in a sequencer script 
Thanks, this seems very helpful, and we'll give it a try.

> > I have a possibly simple feature request for the MIDAS sequencer.  It would be
> > helpful to be able to save an ODB key's value to a variable, for later use, and
> > would be the analogue of the ODBSET command.  I had in mind an application where
> > a user wants to temporarily change some settings in the ODB, then restore the
> > ODB to its original values.  Maybe something like on ODBRead command:
> 
> I implemented your request, committed the changed to GIT and updated the documentation. Now you can run 
> things like:
> 
> ODBSET /System/tmp/test 1234 
> ODBGET /System/tmp/test v 
> MESSAGE $v 
> 
> (first you must create the key in the ODB manually).
> 
> Best regards,
> Stefan