Entry  14 Oct 2014, Konstantin Olchanski, Bug Report, Problem in mfe multithread equipments 
    Reply  14 Oct 2014, Konstantin Olchanski, Bug Report, Problem in mfe multithread equipments 
    Reply  15 Oct 2014, Stefan Ritt, Bug Report, Problem in mfe multithread equipments 
       Reply  15 Oct 2014, Stefan Ritt, Bug Report, Problem in mfe multithread equipments 
    Reply  16 Oct 2014, Stefan Ritt, Bug Report, Problem in mfe multithread equipments 
Message ID: 1030     Entry time: 16 Oct 2014     In reply to: 1021
Author: Stefan Ritt 
Topic: Bug Report 
Subject: Problem in mfe multithread equipments 
> while (1)
>    wait 10 ms for an event
>    process event, loop back
>    if there is no event, exit
> }


This code has been rewritten now and should work for event rates >100 Hz.

/Stefan