Back Midas Rome Roody Rootana
  Midas DAQ System  Not logged in ELOG logo
Message ID: 141     Entry time: 26 Jul 2003
Author: Konstantin Olchanski 
Topic:  
Subject: use "odbedit -C" to connect to corrupted ODB 
Add switch "-C" to odbedit to allow it to connect to corrupted ODB. Then,
depending on corruption, the user can manually remove or correct the
corrupted entries. Also, some corruption is automatically fixed by "odbedit"
itself. I use this functionality to debug and fix broken ODBs.

K.O.

For your enjoyment, here is the diff:

diff -r1.64 odbedit.c
3058a3059
> BOOL          corrupted;
3063c3064
<   debug = cmd_mode = FALSE;
---
>   debug = corrupted = cmd_mode = FALSE;
3077a3079,3080
>     else if (argv[i][0] == '-' && argv[i][1] == 'C')
>       corrupted = TRUE;
3104c3107,3108
<         printf("               [-c Command] [-c @CommandFile] [-s size]
[-g (debug)]\n\n");
---
>         printf("               [-c Command] [-c @CommandFile] [-s size]\n");
>         printf("               [-g (debug)] [-C (connect to corrupted
ODB)]\n\n");
3123c3127,3133
<   if (status != CM_SUCCESS)
---
>   else if ((status == DB_INVALID_HANDLE)&&corrupted)
>     {
>     cm_get_error(status, str);
>     puts(str);
>     printf("ODB is corrupted, connecting anyway...\n");
>     }
>   else if (status != CM_SUCCESS)
ELOG V3.1.4-2e1708b5