Entry time: 18 Mar 2019
In reply to: 1499
Reply to this: 1506
|
Author: |
Konstantin Olchanski |
Topic: |
Bug Report |
Subject: |
mhttpd - slowcontrol frontend - multi class driver |
|
|
> When using a slowcontrol frontend which operates a device using the multi class
> driver the current midas version (ec3225902d6) has the following issue:
>
> There is a row labeled with: All Input Output
>
This is the "slow control" page you enter by clicking on the equipment name
on the midas status page, yes?
There is some kid of logic behind that link that send one either to the ODB page
for /Eq/XXX/Variables or to the "slow control" page that displays
/Eq/XXX/Variables in a table.
I just tried it and I cannot get to this page in my test experiment, so it will take
a few minutes for me to reproduce your problem. But I think I know where the breakage
is - with the new URL scheme, the links for selecting which variable to show either
was not converted to the new URL scheme or there is a bug and it send us to the wrong place.
I do not remember testing that code, so I will take a look at it definitely.
> Currently this leads to the following error message:
> Error: cannot find key LS336/Variables/Input
Looks like the /Equipment part is missing from the ODB path...
K.O. |