Entry  13 Oct 2004, Konstantin Olchanski, Suggestion, No al_clear_alarm()? 
    Reply  13 Oct 2004, Stefan Ritt, Suggestion, No al_clear_alarm()? 
       Reply  13 Oct 2004, Konstantin Olchanski, Suggestion, No al_clear_alarm()? 
Message ID: 161     Entry time: 13 Oct 2004     In reply to: 160     Reply to this: 162
Author: Stefan Ritt 
Topic: Suggestion 
Subject: No al_clear_alarm()? 
> We have al_trigger_alarm(), but no matching al_clear_alarm(), and I need it to
> clear my alarm once the alarm condition no longer exists. Any objections if I
> add this function? K.O.

The idea is that once an alarm got triggered, it stays until the user
acknowledged, even if the alarm condition has been disappeared. Through mhttpd,
the user can press the "Reset" button, which then executes al_reset_alarm().
However, it is possible to call al_reset_alarm() directly from user code to
achieve the same thing.