Back Midas Rome Roody Rootana
  Midas DAQ System  Not logged in ELOG logo
Entry  08 Jul 2019, Vinzenz Bildstein, Bug Report, Frontend killed at stop of run 
    Reply  08 Jul 2019, Konstantin Olchanski, Bug Report, Frontend killed at stop of run 
       Reply  08 Jul 2019, Vinzenz Bildstein, Bug Report, Frontend killed at stop of run 
          Reply  08 Jul 2019, Konstantin Olchanski, Bug Report, Frontend killed at stop of run 
             Reply  08 Jul 2019, Vinzenz Bildstein, Bug Report, Frontend killed at stop of run 
                Reply  08 Jul 2019, Konstantin Olchanski, Bug Report, Frontend killed at stop of run 
                   Reply  08 Jul 2019, Vinzenz Bildstein, Bug Report, Frontend killed at stop of run 
                      Reply  10 Jul 2019, Vinzenz Bildstein, Bug Report, Frontend killed at stop of run 
                         Reply  10 Jul 2019, Konstantin Olchanski, Bug Report, Frontend killed at stop of run 
                            Reply  11 Jul 2019, Vinzenz Bildstein, Bug Report, Frontend killed at stop of run 
                               Reply  11 Jul 2019, Konstantin Olchanski, Bug Report, Frontend killed at stop of run 
                                  Reply  16 Jul 2019, Konstantin Olchanski, Bug Report, a3818 and signals, Frontend killed at stop of run 
                                     Reply  16 Jul 2019, Konstantin Olchanski, Bug Report, a3818 and signals, Frontend killed at stop of run 
Message ID: 1614     Entry time: 11 Jul 2019     In reply to: 1613     Reply to this: 1622
Author: Konstantin Olchanski 
Topic: Bug Report 
Subject: Frontend killed at stop of run 
> Wed Jul 10 06:23:58 2019 [mhttpd,ERROR] [system.c:4580:ss_recv_net_command,ERROR] timeout receiving network  command header
> Wed Jul 10 06:23:58 2019 [mhttpd,ERROR] [midas.c:10322:rpc_client_call,ERROR] call to "fedescant" on  "grsmid00.triumf.ca" RPC "rc_transition": timeout waiting for reply

We should have started debugging from here. The error messages mean: your frontend is not responding to run transition (RPC timeout).

> problem in the communication via the A3818 card from CAEN.

Yes, this has been problematic before.

K.O.