Message ID: 1715     Entry time: 29 Sep 2019     In reply to: 1712     Reply to this: 1726
Author: Konstantin Olchanski 
Topic: Suggestion 
Subject: recover daq and hardware safety. 
> 
> The issue occurs when e.g. one channel can not be turned on and ramp for some temp/specific 
> reason, and someone else is working on the daq and reloads the odb for e.g. 1h ago.  
> 

So you want to ensure that some HV channels are turned off and stay turned off. Yes?

Most effective solution will depend on the consequences of unwanted turning-on of your channels:

- if hardware is destroyed if turned on - I think you should have a hardware lock-out. (unplug the HV cable)
- if hardware malfunctions and will degrade if left turned on for long time (i.e. a hot phototube or sparking wire chamber) - your data 
monitoring software should detect the anomaly (it will show up as a hot channel, dead channel, etc) and the people running the 
experiment will realize the mistake and turn the channel back off. also hardware monitoring (HV currents, etc) should detect this, with 
same effect.
- if collected data becomes useless (the turned-off channel make big noise in all other channels), then same thing, your data 
monitoring should catch it.

The next consideration is what are you protecting against:

a) one person flags channel defective, turns it off, next person knows nothing, turns it back on - you need to work on documentation, 
shift hand-off and other human-level procedures
b) people running experiment load random odb files - same thing, from human-level procedures and documentation it should be made 
clear which odb files are correct and which should not be used
c) software malfunction (not human person) causes data change in odb causes turned-off channel to turn back on
d) hardware malfunction causes turned-off channel to turn back on (HV power supply hardware or firmware malfunctions and decides 
that all channels should be turned on at maximum high voltage)

In the experiments I am most familiar with, problem (b) is avoided by never loading/reloading odb files directly, most/all interaction
with the experiment is done through web pages, and these web pages are carefully coded to be safe against most user mistakes.

Cases (a), (b) and (c) you can protect against by changing the frontend code to refuse to turn on some channels:

int set_hv(int channel, int voltage) {
   if (channel == 35) return COMMAND_REFUSED;
   write_to_hardware(channel, voltage);
   return COMMAND_SUCCESS;
}

But in reality this solution only creates problem (e):

e) people running the experiment start random versions of the frontend program, make random changes to the frontend source code, 
multiple people working on the frontend have their own personal versions/copies of the source code, etc.

This is the worst-case scenario, meaning the experiment lost control of software configuration, and even basic software version 
control tools (like svn or git) are not being used. If your experiment gets that chaotic, all protections are likely to be ineffective - 
documentation will not work (people will ignore post-it notes "do not turn on!"), hardware protections will not work (unplugged cable 
labeled "do not plug in!" will be plugged back in and powered), etc. good luck, then.

K.O.