Entry  07 Apr 2020, Ivo Schulthess, Suggestion, Sequencer loop break 
    Reply  21 Apr 2020, Stefan Ritt, Suggestion, Sequencer loop break 
       Reply  23 Apr 2020, Ivo Schulthess, Suggestion, Sequencer loop break 
          Reply  23 Apr 2020, Stefan Ritt, Suggestion, Sequencer loop break 
       Reply  25 Apr 2020, Konstantin Olchanski, Suggestion, Sequencer loop break 
Message ID: 1885     Entry time: 25 Apr 2020     In reply to: 1875
Author: Konstantin Olchanski 
Topic: Suggestion 
Subject: Sequencer loop break 
> LOOP runs, 5
> ...
> ENDLOOP

Classical loop constructs usually include "break" (exit the loop) and "continue" (loop again!) 
constructs. I would say it is an unfortunate omission if they are not present in the midas sequencer.

But Stefan is right, of course, both commands are just funny names for "goto".

K.O.