Entry  10 Jun 2020, Ivo Schulthess, Forum, slow-control equipment crashes when running multi-threaded on a remote machine 
    Reply  10 Jun 2020, Konstantin Olchanski, Forum, slow-control equipment crashes when running multi-threaded on a remote machine 
       Reply  10 Jun 2020, Stefan Ritt, Forum, slow-control equipment crashes when running multi-threaded on a remote machine 
          Reply  12 Jun 2020, Ivo Schulthess, Forum, slow-control equipment crashes when running multi-threaded on a remote machine 
Message ID: 1942     Entry time: 10 Jun 2020     Reply to this: 1944
Author: Ivo Schulthess 
Topic: Forum 
Subject: slow-control equipment crashes when running multi-threaded on a remote machine 
Dear all

To reduce the time needed by Midas between runs, we want to change some of our periodic equipment to multi-threaded slow-control equipment. To do that I wanted to start from 
the slowcont with the multi/hv class driver and the nulldev device driver and null bus driver. The example runs fine as it is on the local midas machine and also on remote 
machines. When adding the DF_MULTITHREAD flag to the device driver list, it does not run anymore on remote machines but aborts with the following assertion:

scfe: /home/neutron/packages/midas/src/midas.cxx:1569: INT cm_get_path(char*, int): Assertion `_path_name.length() > 0' failed.

Running the frontend with GDB and set a breakpoint at the exit leads to the following: 

(gdb) where
#0  0x00007ffff68d599f in raise () from /lib64/libc.so.6
#1  0x00007ffff68bfcf5 in abort () from /lib64/libc.so.6
#2  0x00007ffff68bfbc9 in __assert_fail_base.cold.0 () from /lib64/libc.so.6
#3  0x00007ffff68cde56 in __assert_fail () from /lib64/libc.so.6
#4  0x000000000041efbf in cm_get_path (path=0x7fffffffd060 "P\373g", path_size=256)
    at /home/neutron/packages/midas/src/midas.cxx:1563
#5  cm_get_path (path=path@entry=0x7fffffffd060 "P\373g", path_size=path_size@entry=256)
    at /home/neutron/packages/midas/src/midas.cxx:1563
#6  0x0000000000453dd8 in ss_semaphore_create (name=name@entry=0x7fffffffd2c0 "DD_Input", 
    semaphore_handle=semaphore_handle@entry=0x67f700 <multi_driver+96>)
    at /home/neutron/packages/midas/src/system.cxx:2340
#7  0x0000000000451d25 in device_driver (device_drv=0x67f6a0 <multi_driver>, cmd=<optimized out>)
    at /home/neutron/packages/midas/src/device_driver.cxx:155
#8  0x00000000004175f8 in multi_init(eqpmnt*) ()
#9  0x00000000004185c8 in cd_multi(int, eqpmnt*) ()
#10 0x000000000041c20c in initialize_equipment () at /home/neutron/packages/midas/src/mfe.cxx:827
#11 0x000000000040da60 in main (argc=1, argv=0x7fffffffda48)
    at /home/neutron/packages/midas/src/mfe.cxx:2757

I also tried to use the generic class driver which results in the same. I am not sure if this is a problem of the multi-threaded frontend running on a remote machine or is it 
something of our system which is not properly set up. Anyway I am running out of ideas how to solve this and would appreciate any input. 

Thanks in advance,
Ivo