|  02 Sep 2020, Ruslan Podviianiuk, Forum, Transition status message   |  |  02 Sep 2020, Ben Smith, Forum, Transition status message |  |  02 Sep 2020, Ruslan Podviianiuk, Forum, Transition status message |  |  08 Sep 2020, Konstantin Olchanski, Forum, Transition status message |  |  08 Sep 2020, Ruslan Podviianiuk, Forum, Transition status message |  | 
| 
| Message ID: 1996
    Entry time: 08 Sep 2020
    In reply to: 1995 |  | | Author: | Ruslan Podviianiuk |  | Topic: | Forum |  | Subject: | Transition status message | 
 |  | 
| > > > The information you want is in the ODB:
> > > * "/System/Transition/status" is the overall integer status code.
> > > * "/System/Transition/error" is the overall error message string.
> > > 
> > > There is also per-client status information in the ODB:
> > > * "/System/Transition/Clients/<client_name>/status"
> > > * "/System/Transition/Clients/<client_name>/error"
> 
> You can also use web page .../resources/transition.html as an example of how
> to read transition (and other) data from ODB into your own web page. example.html
> may also be helpful.
> 
> K.O.
Thank you Konstantin!
Ruslan |