Back
Midas
Rome
Roody
Rootana
|
Midas DAQ System |
Not logged in |
|
|
|
Message ID: 2152
Entry time: 14 Apr 2021
In reply to: 2144
Reply to this: 2157
|
Author: |
Stefan Ritt |
Topic: |
Suggestion |
Subject: |
Time zone selection for web page |
|
|
> The new history as well as the clock in the web page header show the local time
> of the user's computer running the browser.
> Would it be possible to make it either always use the time zone of the Midas
> server, or make it selectable from the config page?
> It's not ideal trying to relate error messages from the midas.log to history
> plots if the time stamps don't match.
I implemented a new row in the config page to select the time zone.
"Local": Time zone where the browser runs
"Server": Time zone where the midas server runs (you have to update mhttpd for that)
"UTC+X": Any other time zone
The setting affects both the status header and the history display.
I spent quite some time with "named" time zones like "PST" "EST" "CEST", but the
support for that is not that great in JavaScript, so I decided to go with simple
UTC+X. Hope that's ok.
Please give it a try and let me know if it's working for you.
Best,
Stefan |
|