Message ID: 2591     Entry time: 17 Aug 2023     In reply to: 2588     Reply to this: 2593
Author: Konstantin Olchanski 
Topic: Bug Report 
Subject: Error accessing history files 
Confirmed. The error message is wrong. It is printed after a short read(), but short read() does not 
set errno, and errno reported by the error message is from some previous syscall. Corrected error 
message is already committed. K.O.


> Tonight we got another error of that type after the update:
> 
> 04:17 - [mhttpd,ERROR] [history_schema.cxx:2913:FileHistory::read_data,ERROR] Cannot read 
> '/data2/history/mhf_1692128214_20230815_gassystem.dat', read() errno 2 (No such file or directory)
> 
> This morning I looked at the file, and it was there:
> 
> [meg@megon02 history]$ ls -alg mhf_1692128214_20230815_gassystem.dat
> -rw-rw-r--. 1 meg 4663228 Aug 17 08:50 mhf_1692128214_20230815_gassystem.dat
> [meg@megon02 history]$
> 
> 
> Stefan