Back Midas Rome Roody Rootana
  Midas DAQ System  Not logged in ELOG logo
Entry  11 Dec 2023, Pavel Murat, Forum, the logic of handling history variables ? 11x
    Reply  11 Dec 2023, Stefan Ritt, Forum, the logic of handling history variables ? Screenshot_2023-12-12_at_09.03.13.pngScreenshot_2023-12-12_at_08.57.45.pngScreenshot_2023-12-12_at_08.55.14.pngScreenshot_2023-12-12_at_08.57.37.png
       Reply  12 Dec 2023, Pavel Murat, Forum, the logic of handling history variables ? 
          Reply  13 Dec 2023, Stefan Ritt, Forum, the logic of handling history variables ? 
    Reply  28 Jan 2024, Konstantin Olchanski, Forum, the logic of handling history variables ? 
Message ID: 2656     Entry time: 12 Dec 2023     In reply to: 2653     Reply to this: 2657
Author: Pavel Murat 
Topic: Forum 
Subject: the logic of handling history variables ? 
Hi Sfefan, thanks a lot for taking time to reproduce the issue! 

Here comes the resolution, and of course, it was something deeply trivial :  

the definition of the HV equipment in midas/examples/slowcont/scfe.cxx has 
the history logging time in seconds, however the comment suggests milliseconds (see below), 
and for a few days I believed to the comment (:smile:)

Easy to fix. 

Also, I think that having a sine wave displayed by midas/examples/slowcont/scfe.cxx 
would make this example even more helpful.

-- thanks again, regards, Pasha

--------------------------------------------------------------------------------------------------------
EQUIPMENT equipment[] = {

   {"HV",                       /* equipment name */
    {3, 0,                      /* event ID, trigger mask */
     "SYSTEM",                  /* event buffer */
     EQ_SLOW,                   /* equipment type */
     0,                         /* event source */
     "FIXED",                   /* format */
     TRUE,                      /* enabled */
     RO_RUNNING | RO_TRANSITIONS,        /* read when running and on transitions */
     60000,                     /* read every 60 sec */
     0,                         /* stop run after this event limit */
     0,                         /* number of sub events */
     10000,                     /* log history at most every ten seconds */ // <------------ this is 10^4 seconds, not 10 seconds
     "", "", ""} ,
    cd_hv_read,                 /* readout routine */
    cd_hv,                      /* class driver main routine */
    hv_driver,                  /* device driver list */
    NULL,                       /* init string */
    },


https://bitbucket.org/tmidas/midas/src/7f0147eb7bc7395f262b3ae90dd0d2af0625af39/examples/slowcont/scfe.cxx#lines-81