Back Midas Rome Roody Rootana
  Midas DAQ System  Not logged in ELOG logo
Entry  29 Apr 2024, Musaab Al-Bakry, Forum, Midas Sequencer with less than 1 second wait 
    Reply  29 Apr 2024, Stefan Ritt, Forum, Midas Sequencer with less than 1 second wait 
       Reply  30 Apr 2024, Scott Oser, Forum, Midas Sequencer with less than 1 second wait 
          Reply  30 Apr 2024, Stefan Ritt, Forum, Midas Sequencer with less than 1 second wait 
             Reply  30 Apr 2024, Scott Oser, Forum, Midas Sequencer with less than 1 second wait 
                Reply  30 Apr 2024, Stefan Ritt, Forum, Midas Sequencer with less than 1 second wait 
                   Reply  30 Apr 2024, Scott Oser, Forum, Midas Sequencer with less than 1 second wait 
                      Reply  02 May 2024, Stefan Ritt, Forum, Midas Sequencer with less than 1 second wait 
                         Reply  02 May 2024, Scott Oser, Forum, Midas Sequencer with less than 1 second wait 
                            Reply  05 May 2024, Musaab Al-Bakry, Forum, Midas Sequencer with less than 1 second wait 
                               Reply  06 May 2024, Stefan Ritt, Forum, Midas Sequencer with less than 1 second wait 
                                  Reply  06 May 2024, Stefan Ritt, Forum, Midas Sequencer with less than 1 second wait 
                                     Reply  07 May 2024, Musaab Al-Bakry, Forum, Midas Sequencer with less than 1 second wait 
Message ID: 2749     Entry time: 02 May 2024     In reply to: 2748     Reply to this: 2759
Author: Scott Oser 
Topic: Forum 
Subject: Midas Sequencer with less than 1 second wait 
> Ok, I implemented the float second wait function. Internally it works in ms, so the maximum resolution is 0.001 s.
> 
> Best,
> Stefan

Thank you, we will test this soon and let you know if we see any issues (but we're not expecting any).