Entry  29 Dec 2024, Pavel Murat, Forum, time ordering of run transition calls to TMFeEquipment things 
    Reply  01 Jan 2025, Konstantin Olchanski, Forum, time ordering of run transition calls to TMFeEquipment things 
       Reply  02 Jan 2025, Pavel Murat, Forum, time ordering of run transition calls to TMFeEquipment things 
          Reply  05 Jan 2025, Stefan Ritt, Forum, time ordering of run transition calls to TMFeEquipment things 
Message ID: 2926     Entry time: 29 Dec 2024     Reply to this: 2927
Author: Pavel Murat 
Topic: Forum 
Subject: time ordering of run transition calls to TMFeEquipment things 
Dear MIDAS experts, 

I have a question about "tmfe approach" to implementing MIDAS frontends. If I read the code correctly, 
within this approach it is the TMFeEquipment things, not the TMFrontend's themselves, 
which handle the run transitions - the TMFrontend class 

https://bitbucket.org/tmidas/midas/src/423082fb67c7711813fcda61f7cd03784c398f49/include/tmfe.h#lines-306:378

simply doesn't have methods to handle those directly. 

So how does a user control the sequence in which TMFeEquipment::HandleBeginRun functions of different 
TMFeEquipment pieces are called at begin run? - there are two cases to consider: TMFeEquipment things 
defined by the same TMFrontend and by different TMFrontend's.

Many thanks and happy holidays to everyone! 

-- regards, Pasha
 