> I am having problems with handling the end-of-run situation in my midas
> frontend. I have a device that continuously sends data (over USB) and I read
> this data in my "read_event" function.
>
> Everything is good until the end-of-run, at which time this happens:
> 0) mfe.c calls my read_event() to read the data (loop until the end-of-run
> transition)
> 1) mfe.c calls my end_of_run()
> 2) here, I tell the device "please stop sending data"
> 3) all seems good, but wait!!!
> 4) there is all this data generated between step 0 and step 2 still sitting
> inside the device and it has nowhere to go: the run is ended, the output file is
> closed, my read_event() will never be called ever again (well, until the next run).
>
> It seems to me mfe.c needs to have one more function, something like
> "pre_end_of_run()" that works like this:
> 0) mfe.c calls my read_event() to read the data (loop until the end-of-run
> transition)
> 1) mfe.c calls pre_end_of_run(), here I tell the device to stop sending data
> 2) mfe.c calls read_event() for the very last time, to give me the opportunity
> to read and send away any data I still may have.
> 3) mfe.c calls the end_of_run(). The run is truely finished.
>
> Any thoughts?
You can achieve the desired functionality without changing mfe.c:
0) mfe.c calls read_event
1) mfe.c calls end_of_run. Your end_of_run tells the device to stop data and flushes
the remaining data. At this point you have to re-make actually a part of the mfe.c
functionality, but basically you need a bm_compose_event() and a bm_send_event(), so
just a few lines of code. If you want to have the final event number right in your
equipment, you also need to update eq->events_sent accordingly.
Given the fact that 99% of the experiments do not need this functionality, I propose
that we keep mfe.c and you add the few lines of code into your user part of the
specific frontend.
Stefan |