Back Midas Rome Roody Rootana
  Midas DAQ System  Not logged in ELOG logo
Entry  07 May 2009, Konstantin Olchanski, Bug Report, mlogger duplicate event problem 
    Reply  02 Jun 2009, Konstantin Olchanski, Bug Report, mlogger duplicate event problem 
       Reply  16 Jun 2009, Konstantin Olchanski, Bug Report, mlogger duplicate event problem 
          Reply  24 Jun 2009, Konstantin Olchanski, Bug Report, TR_STARTABORT transition, mlogger duplicate event problem 
             Reply  25 Jun 2009, Stefan Ritt, Bug Report, TR_STARTABORT transition, mlogger duplicate event problem 
                Reply  25 Jun 2009, Konstantin Olchanski, Bug Report, TR_STARTABORT transition, mlogger duplicate event problem 
                   Reply  25 Jun 2009, Stefan Ritt, Bug Report, TR_STARTABORT transition, mlogger duplicate event problem 
Message ID: 602     Entry time: 25 Jun 2009     In reply to: 601
Author: Stefan Ritt 
Topic: Bug Report 
Subject: TR_STARTABORT transition, mlogger duplicate event problem 
> Are you sure? Only clients that register themselves to receive the TR_STARTABORT transition (via cm_register_transition()) will receive this transition.
> 
> As of now, the only client that registers and receives this transition is mlogger.
> 
> I also confirm that old clients that know nothing about TR_STARTABORT are *not* sent this transition. (this is tested).

Ok, then we are fine.
ELOG V3.1.4-2e1708b5