> More generally I kind of consider the mlogger auto restart facility as deprecated. It works in the background and the operator does not have a clue
> what is going on. We use now the sequencer to achieve exactly the same functionality.
>
Before subruns were available, most experiments at TRIUMF have used the "auto restart" function. Now, I think most of them use subruns,
with the notable exception of PIENU where the analysis framework could not handle subruns. (PIENU is now shutdown and disassembled).
>
> It just requires a few lines of sequencer code:
>
> LOOP INFINITE
> TRANSITION start
> WAIT events, 5000
> TRANSITION stop
> ENDLOOP
>
Mouse click "auto restart" to "yes" is a little bit simpler than setting up a sequencer file, and it survives a crash of mhttpd.
Does the sequencer survive a crash or a restart of mhttpd?
K.O. |