  2747   30 Apr 2024 Scott OserForumMidas Sequencer with less than 1 second wait
> While I will do it, i'm not sure if this is what you want. If I understand correctly, some process gets triggered and then writes some values to the ODB, then the sequencer 
> should continue. Putting a wait there is dangerous. Maybe your process always takes like 10-20 ms, so you put a wait of let's say 100ms, and things are fine with you. Your 
> script runs many days, but then once in a while your machine is on heavy load because someone starts a web browser, and your process takes 110ms, and you script crashes.
> 
> I would rather go following path: put a "done" flag in the ODB, which is the last one which gets set by your process. Then the sequencer does a 
> 
> WAIT ODBvalue, /path/value, =, 1
> 
> which will work always, independend of the delay of your process.
> 
> Stefan

Our use case is pretty simple and I don't think is affected by the scenario you envision.  We want to turn on a setting in our equipment, and turn it off again some 0.2 s later.  We don't need msec timing.  So something like:

ODBSET /somekey 1   # this will cause a front-end to flip a bit in our hardware     
WAIT seconds, 0.2
ODBSET /somekey 0   # this will cause a front-end to reset a bit in our hardware 

It is true that if the load is high there could be a little delay, and the time that the bit is set will not be 0.2 seconds, but on average it should work, 
and it should be good enough we think.

Yes, we could also check an ODB key to see that something is done, but we'd still need the ability to wait for time intervals less than 1 second, which
right now doesn't exist.