  528   20 Nov 2008 Jimmy NgaiInfoRecommended platform for running MIDAS
Dear All,

Is there any recommended platforms for running MIDAS? Have anyone encountered 
problems when running MIDAS on Scientific Linux?

Thanks.

Jimmy
  530   26 Nov 2008 Jimmy NgaiInfoSend email alert in alarm system
Dear All,

We have a temperature/humidity sensor in MIDAS now and will add a liquid level 
sensor to MIDAS soon. We want the operators to get alerted ASAP when the 
laboratory environment or the liquid level reached some critical levels. Can 
MIDAS send email alerts or SMS alerts to cell phones when the alarms are 
triggered? If yes, how can I config it?

Many thanks!

Best Regards,
Jimmy
  541   12 Dec 2008 Jimmy NgaiInfoCustom page which executes custom function
Dear All,

How can I add a button at the top of the "Status" webpage which will show a 
page similar to the "CNAF" one after I click on it? and how can I make a 
custom page similar to "CNAF" which allow me to call some custom funtions? I 
want to make a page which is particularly for doing calibration.

Thank you for your attention!

Best Regards,
Jimmy Ngai
  565   17 Apr 2009 Jimmy NgaiForumMIDAS mhttpd custom page questions
Dear All,

I have created a custom page (please see the attachment) and imported into 
MIDAS with key name "Control panel&" (without the ""). I have the following 
two questions:

1) I display the status of the run with <odb src="/Runinfo/State">, but it 
returns numbers which is not user friendly. How can I make something 
like "Running" with green background and "Stopped" with red background in the 
default status page?

2) When I click either Start/Stop/Pause/Resume, it can performs the right 
things, but afterward it jumps to the page "http://domain.name:8081/CS/" which 
shows "Invalid custom page: NULL path". How can I make it returns to the 
correct page "http://domain.name:8081/CS/Control%20panel"?

Thank you for your attention.

Best Regards,
Jimmy
  566   20 Apr 2009 Jimmy NgaiForumMIDAS mhttpd custom page questions
Dear All,

I have one more question. I use <odb src="odb field" edit=1> to display an 
editable ODB value, but how can I show this value in hexadecimal?

Thanks.

Best Regards,
Jimmy


> Dear All,
> 
> I have created a custom page (please see the attachment) and imported into 
> MIDAS with key name "Control panel&" (without the ""). I have the following 
> two questions:
> 
> 1) I display the status of the run with <odb src="/Runinfo/State">, but it 
> returns numbers which is not user friendly. How can I make something 
> like "Running" with green background and "Stopped" with red background in the 
> default status page?
> 
> 2) When I click either Start/Stop/Pause/Resume, it can performs the right 
> things, but afterward it jumps to the page "http://domain.name:8081/CS/" which 
> shows "Invalid custom page: NULL path". How can I make it returns to the 
> correct page "http://domain.name:8081/CS/Control%20panel"?
> 
> Thank you for your attention.
> 
> Best Regards,
> Jimmy
  594   15 Jun 2009 Jimmy NgaiForumTime limit of each run
Dear All,

Can one set a time limit for each run? I can only find event limit in ODB. 
Thanks.

Jimmy
  624   01 Sep 2009 Jimmy NgaiForumTimeout during run transition
Dear All,

I'm using SL5 and MIDAS rev 4528. Occasionally, when I stop a run in odbedit, 
a timeout would occur: 
[midas.c:9496:rpc_client_call,ERROR] rpc timeout after 121 sec, routine 
= "rc_transition", host = "computerB", connection closed
Error: Unknown error 504 from client 'Frontend' on host computerB

This error seems to be random without any reason or pattern. After this error 
occurs, I cannot start or stop any run. Sometime restarting MIDAS can bring 
the system working again, but sometime not.

Another transition timeout occurs after I change any ODB value using the web 
interface:
[midas.c:8291:rpc_client_connect,ERROR] timeout on receive remote computer 
info: 
[midas.c:3642:cm_transition,ERROR] cannot connect to client "Frontend" on host 
computerB, port 36255, status 503
Error: Cannot connect to client 'Frontend'

This error is reproducible: start run -> change ODB value within webpage -> 
stop run -> timeout!

Any idea?

Thanks,
Jimmy
  642   09 Sep 2009 Jimmy NgaiForumRetrieve start/stop time in offline
Hi All,

I set "/Analyzer/ODB Load" to true and analyzed a run in offline mode. After
that, I found the start time and stop time in /RunInfo did not reflect the
correct time as in online. How do I retrieve the correct start/stop time from
the ODB in offline mode?

Thanks!

Jimmy
  669   06 Nov 2009 Jimmy NgaiForumRun multiple frontend on the same host
Dear All,

I want to run two frontend programs (one for trigger and one for slow control)
concurrently on the same computer, but I failed. The second frontend said: 

Semaphore already present
 There is another process using the semaphore.
 Or a process using the semaphore exited abnormally.
 In That case try to manually release the semaphore with:
   ipcrm sem XXX.

The two frontends are connected to the same experiment. Is there any way I can
overcome this problem?

Thanks!

Jimmy
  687   07 Dec 2009 Jimmy NgaiForumRun multiple frontend on the same host
Dear Stefan,

Thanks for the reply. I have tried your patch and it didn't solve my problem. Maybe I 
have not written my question clearly. The two frontends could run on the same computer 
if I use the remote method, i.e. by setting up the mserver and connect to the 
experiment by specifying "-h localhost", also the frontend programs need to be put in 
different directory. What I want to know is whether I can simply start multiple 
frontends in the same directory without setting up the mserver etc. I noticed that 
there are several *.SHM files, I'm not familiar with semaphore, but I guess they are 
the key to the problem. Please correct me if I misunderstood something.

Best Regards,
Jimmy


> > Dear All,
> > 
> > I want to run two frontend programs (one for trigger and one for slow control)
> > concurrently on the same computer, but I failed. The second frontend said: 
> > 
> > Semaphore already present
> >  There is another process using the semaphore.
> >  Or a process using the semaphore exited abnormally.
> >  In That case try to manually release the semaphore with:
> >    ipcrm sem XXX.
> > 
> > The two frontends are connected to the same experiment. Is there any way I can
> > overcome this problem?
> 
> That might be related to the RPC mutex, which gets created system wide now. I 
> modified this in midas.c rev. 4628, so there will be one mutex per process. Can you 
> try that temporary patch and tell me if it works for you?
  689   12 Dec 2009 Jimmy NgaiForumRun multiple frontend on the same host
Dear Stefan,

I followed your suggestion to try the sample front-ends from the distribution and 
they work fine. They also work fine with any one of my front-ends. Only my two 
front-ends cannot run concurrently in the same directory. I later found that the 
problem is in the CAEN HV wrapper library. The problem arises when the front-ends 
are both linked to that library and it is solved now.

Thanks & Best Regards,
Jimmy


> Hi Jimmy,
> 
> ok, now I understand. Well, I don't see your problem. I just tried with the 
> current SVN 
> version to start
> 
> midas/examples/experiment/frontend
> midas/examples/slowcont/scfe
> 
> in the same directory (without "-h localhost") and it works just fine (see 
> attachemnt). I even started them from the same directory. Yes there are *.SHM 
> files and they correspond to shared memory, but both front-ends use this shared 
> memory together (that's why it's called 'shared').
> 
> Your error message 'Semaphore already present' is strange. The string is not 
> contained in any midas program, so it must come from somewhere else. Do you 
> maybe try to access the same hardware with the two front-end programs?
> 
> I would propose you do the following: Use the two front-ends from the 
> distribution (see above). They do not access any hardware. See if you can run 
> them with the current SVN version of midas. If not, report back to me.
> 
> Best regards,
> 
>   Stefan
> 
> 
> > Dear Stefan,
> > 
> > Thanks for the reply. I have tried your patch and it didn't solve my problem. 
> Maybe I 
> > have not written my question clearly. The two frontends could run on the same 
> computer 
> > if I use the remote method, i.e. by setting up the mserver and connect to the 
> > experiment by specifying "-h localhost", also the frontend programs need to be 
> put in 
> > different directory. What I want to know is whether I can simply start 
> multiple 
> > frontends in the same directory without setting up the mserver etc. I noticed 
> that 
> > there are several *.SHM files, I'm not familiar with semaphore, but I guess 
> they are 
> > the key to the problem. Please correct me if I misunderstood something.
> > 
> > Best Regards,
> > Jimmy
> > 
> > 
> > > > Dear All,
> > > > 
> > > > I want to run two frontend programs (one for trigger and one for slow 
> control)
> > > > concurrently on the same computer, but I failed. The second frontend said: 
> > > > 
> > > > Semaphore already present
> > > >  There is another process using the semaphore.
> > > >  Or a process using the semaphore exited abnormally.
> > > >  In That case try to manually release the semaphore with:
> > > >    ipcrm sem XXX.
> > > > 
> > > > The two frontends are connected to the same experiment. Is there any way I 
> can
> > > > overcome this problem?
> > > 
> > > That might be related to the RPC mutex, which gets created system wide now. 
> I 
> > > modified this in midas.c rev. 4628, so there will be one mutex per process. 
> Can you 
> > > try that temporary patch and tell me if it works for you?
  698   22 Apr 2010 Jimmy NgaiForumHow to stop a run with a timer?
Hi Exaos,

This may help: https://ladd00.triumf.ca/elog/Midas/645

You need to set the following keys:
/Logger/Run duration
/Logger/Auto restart
/Logger/Auto restart delay

Regards,
Jimmy


> I want to let the run stop and start periodically. But I looked through the ODB
> and didn't find anything may help. I also checked the FAQ online and didn't find
> answer either. Who can help me? Thank you.
  699   22 Apr 2010 Jimmy NgaiForumCustomized "Start" page
Dear All,

After clicking the "Start" button, there is a page for the operator to change some 
ODB values. I have created "/Experiment/Edit on start" and added some links there. 
If the link is pointed to a boolean type key, a check box will appear in the 
"Start" page, which is great. But how about if I want to have some radio buttons 
or pull-down menus for the operator to select among different calibration sources 
or running modes?

Thanks,

Jimmy
  706   24 Jun 2010 Jimmy NgaiForumError connecting to back-end computer
Dear All,

This is my first time running an experiment on separate computers. I followed 
the documentation (https://midas.psi.ch/htmldoc/quickstart.html) to setup the 
files:
/etc/services
/etc/xinetd.d/midas
/etc/ld.so.conf
/etc/exptab

but when I started the frontend program in the front-end computer I got the 
following error (computerB is my back-end): 

[midas.c:8623:rpc_server_connect,ERROR] mserver subprocess could not be started 
(check path)
[mfe.c:2573:mainFE,ERROR] Cannot connect to experiment '' on host 'computerB', 
status 503

In both front-end and back-end computers only a file '.SYSMSG.SHM' was created 
after the attempt. If I start the frontend program somewhere in the back-end 
computer by connecting to 'localhost', seven .SHM files are created in the 
experiment directory together with a .RPC.SHM in the directory where I run the 
frontend program.

Is that I misconfigure something? I cannot find a solution...

Thanks.

Best Regards,
Jimmy
  708   27 Jun 2010 Jimmy NgaiForumError connecting to back-end computer
> Hi, there. I have not recently run mserver through inetd, and we usually do not do
> that at TRIUMF. We do this:
> 
> a) on the main computer: start mserver: "mserver -p 7070 -D" (note - use non-default
> port - can use different ports for different experiments)
> b) on remote computer: "odbedit -h main:7070" ("main" is the hostname of your main
> computer). Use same "-h" switch for all other programs, including the frontends.
> 
> This works well when all computers are on the same network, but if you have some
> midas clients running on private networks you may get into trouble when they try to
> connect to each other and fail because network routing is funny.

Hi K.O.,

Thanks for your reply. I have tried your way but I got the same error: 

[midas.c:8623:rpc_server_connect,ERROR] mserver subprocess could not be started 
(check path)

My front-end and back-end computers are on the same network connected by a router. I 
have allowed port 7070 in the firewall and done the port forwarding in the router (for 
connecting from outside the network). From the error message it seems that some 
processes can not be started automatically. Could it be related to some security 
settings such as the SELinux?

Best Regards,
Jimmy
  710   28 Jun 2010 Jimmy NgaiForumError connecting to back-end computer
> The way connections work under Midas is there is a callback scheme. The client starts 
> mserver on the back-end, then the back-end connects back to the front-end on three 
> different ports. These ports are assigned dynamically by the operating system and are 
> typically in the range 40000-60000. So you also have to allow the reverse connection on 
> your firewalls.

It works now after allowing ports 40000-60000 in the front-end computer. Thanks!

Best Regards,
Jimmy
  761   18 May 2011 Jimmy NgaiForumsimple example frontend for V1720

Jianglai Liu wrote:
Hi,

Who has a good example of a frontend program using CAEN V1718 VME-USB bridge and
V1720 FADC? I am trying to set up the DAQ for such a simple system.

I put together a frontend which talks to the VME. However it gets stuck at
"Calibrating" in initialize_equipment().

I'd appreciate some help!

Thanks,
Jianglai


Hi Jianglai,

I don't have an exmaple of using V1718 with V1720, but I have been using V1718 with V792N for a long time.

You may find in the attachment an example frontend program and my drivers for V1718 and V792N written in MVMESTD format. They have to be linked with the CAENVMELib library and other essential MIDAS stuffs.

Regards,
Jimmy
  763   17 Jun 2011 Jimmy NgaiForumCannot open input file (file too large?)
Dear All,

I got a "Cannot open input file" error when I tried to analyze a .mid.gz file with 
size over 5 GB on a 32-bit Linux. The error traced back to gzopen() in mana.c 
where it returned NULL when opening the file. I understand that 32-bit Linux may 
not be able to handle files with size over 2 GB. I tried to add -
D_LARGEFILE_SOURCE -D_FILE_OFFSET_BITS=64 to CFLAGS in the Makefile of MIDAS and 
the analyzer, but I still got the same error. Is there any workarounds that enable 
me to analyze large files on 32-bit systems?

p.s. The data file was also produced on a 32-bit Linux.

Thanks & Best Regards,

Jimmy
  765   20 Jun 2011 Jimmy NgaiForumCannot open input file (file too large?)
Dear All,

Thanks Konstantin Olchanski for providing me a hint. The file can be opened now after I 
changed the line: 

file->gzfile = gzopen(file_name, "rb");

in function ma_open() in mana.c to the followings: 

INT fd = open(file_name, O_RDONLY | O_LARGEFILE);
if (fd <= 0)
   return NULL;

file->gzfile = gzdopen(fd, "rb");

No modifications to the Makefile is needed in this case.

Best Regards,
Jimmy


> Dear All,
> 
> I got a "Cannot open input file" error when I tried to analyze a .mid.gz file with 
> size over 5 GB on a 32-bit Linux. The error traced back to gzopen() in mana.c 
> where it returned NULL when opening the file. I understand that 32-bit Linux may 
> not be able to handle files with size over 2 GB. I tried to add -
> D_LARGEFILE_SOURCE -D_FILE_OFFSET_BITS=64 to CFLAGS in the Makefile of MIDAS and 
> the analyzer, but I still got the same error. Is there any workarounds that enable 
> me to analyze large files on 32-bit systems?
> 
> p.s. The data file was also produced on a 32-bit Linux.
> 
> Thanks & Best Regards,
> 
> Jimmy
  826   12 Aug 2012 Jimmy NgaiForumsimple example frontend for V1720

Carl Blaksley wrote:

Jimmy Ngai wrote:

Jianglai Liu wrote:
Hi,

Who has a good example of a frontend program using CAEN V1718 VME-USB bridge and
V1720 FADC? I am trying to set up the DAQ for such a simple system.

I put together a frontend which talks to the VME. However it gets stuck at
"Calibrating" in initialize_equipment().

I'd appreciate some help!

Thanks,
Jianglai


Hi Jianglai,

I don't have an exmaple of using V1718 with V1720, but I have been using V1718 with V792N for a long time.

You may find in the attachment an example frontend program and my drivers for V1718 and V792N written in MVMESTD format. They have to be linked with the CAENVMELib library and other essential MIDAS stuffs.

Regards,
Jimmy


Jimmy,

How exactly did you link the CAENVMElib with your frontend? That is the part which I can not seem to replicate using your example frontend!

Thanks,
-Carl


Hi Carl,

Attached is a cut-down version of my original Makefile just for demonstrating how to link the CAENVMElib. I didn't test it for bugs. Please make sure the libCAENVME.so is in your library path.

Jimmy
ELOG V3.1.4-2e1708b5