  Midas DAQ System, Page 119 of 136  Not logged in ELOG logo
ID Date Authorup Topic Subject
  2074   13 Jan 2021 Stefan RittForumpoll_event() is very slow.
Something must be wrong on your side. If you take the example frontend under

midas/examples/experiment/frontend.cxx

and let it run to produce dummy events, you get about 90 Hz. This is because we have a

  ss_sleep(10);

in the read_trigger_event() routine to throttle things down. If you remove that sleep, 
you get an event rate of about 500'000 Hz. So the framework is really quick.

Probably your routine which looks for a 'lam' takes really long and should be fixed.

Stefan
  2080   25 Jan 2021 Stefan RittSuggestionmhttpd browser caching
Let me first explain a bit why caching is there. Once we had the case that someone from 
TRIUMF opened a midas custom page at T2K. It took about one minute (!) to load the page. 

When we looked at it, we found that the custom page pulled about 100 items with individual
HTTP requests from Japan, each taking about one second for the roundtrip. Then we redesigned
the custom page communication so that many ODB entries could be retrieved in one operation,
which improved the loading time from 100s to about 2s.

With the buttons we will have to make the same compromise. If we do not cache anything,
loading the midas status page over the Pacific takes many seconds. If we cache all, any
change on the midas side will not be reflected on the web page. So there is a compromise
to be made. I thought I designed it such that the side menu is cached locally, but when
the user presses "reload", then the full menu is fetched from the server. Of course one
has to remember this, so changing the ELOG URL or other things on the menu require a
reload (or wait a certain time for the cache to expire). So try again if that's working
for you. If not, I can visit it again and check if there is any bug.

If we go the route to disable the cache, better try this to T2K and see what you get before
we commit ourselves to that. Last time TRIUMF people were complaining a lot about long
load times.

Best,
Stefan
  2086   08 Feb 2021 Stefan RittSuggestionmhttpd browser caching
> It seems that the only reliable way to bypass the browser cache is to add
> a tag with a random number to the URL ("&ts=currenttime").

Indeed that's the only reliable way to avoid caching across browsers. An alternative is

("&r=" + Math.random())

to add a random number.


> BTW, things like midas.js are also cached, and it is common to see problems
> after updating midas, where status.html is newly loaded, but midas.js is an old
> stale version from cache.

Reloading JavaScript file NOT from the cache is really tricky these days. I added a
special Google Chrome extension to clear my browser cache, which works reliably:

https://chrome.google.com/webstore/detail/clear-cache/cppjkneekbjaeellbfkmgnhonkkjfpdn

Stefan
  2097   25 Feb 2021 Stefan RittBug Reporthistory reload
I have to reproduce the problem. Can you please send me the full link by direct email. As you know, I'm also at PSI.

Stefan
  2116   02 Mar 2021 Stefan RittInfoshortest possible sleep
Why do you need that? Periodic equipment typically runs ever ten seconds or so, meaning one can do this easily in a scheduler.

For polled equipment, you don't want to sleep at all. Because if you sleep, you might miss an event. That's why I put my poll in mfe.c into a for() loop. No 
sleep, maximum polling rate. I just double checked on my macbook air. 

- If poll is always false (no event available), the loop executes 50M times in 100ms (calibrated during startup of the frontend). That means one iteration 
takes 2ns (!). So if an event occurs, the readout is started with a 2ns overhead. No sleep can beat that. In a real world application, one has to add of course 
the VME access or so to poll for the event.

- If poll is always true, the framework generates about 700k events each second (returning jus a few bytes of event data).

So if one adds any sleep here, things can get only worse, so I don't see the point for that. Of course polling eats one kernel at 100%, but these days every 
CPU has more than one, even my 800 MHz Xilinx embedded ARM CPU (Zynq).

Best,
Stefan
  Draft   04 Mar 2021 Stefan RittForumUsing JSROOT.openFile with Midas
I also need midas events going back to the
  2122   04 Mar 2021 Stefan RittForumUsing JSROOT.openFile with Midas
I also need midas events going back to the browser for single event display, so put +1 for me.

Please also consider to use JavaScript typed arrays instead of JSON. For large midas banks, type 
arrays are 5-10 times faster than JSON encoding/decoding.

Best,
Stefan
  2127   10 Mar 2021 Stefan RittForumINT INT32 in experim.h
Ok, I added

/* define integer types with explicit widths */
#ifndef NO_INT_TYPES_DEFINE
typedef unsigned char      UINT8;
typedef char               INT8;
typedef unsigned short     UINT16;
typedef short              INT16;
typedef unsigned int       UINT32;
typedef int                INT32;
typedef unsigned long long UINT64;
typedef long long          INT64;
#endif

to cover all new types. If there is a collision with user defined types, compile your program with -DNO_INT_TYPES_DEFINE and you remove the 
above definition. I hope there are no other conflicts.

Stefan
  2129   10 Mar 2021 Stefan RittSuggestionembed modbvalue in SVG
You can't really embed it, but you can overlay it. You tag the SVG with a 
"relative" position and then move the modbvalue with an "absolute" position over 
it:

<svg style="position:relative" width="400" height="100">
  <rect width="300" height="100" style="fill:rgb(255,0,0);stroke-width:3;stroke:rgb(0,0,0)" />
  <div class="modbvalue" style="position:absolute;top:50px;left:50px" data-odb-path="/Runinfo/Run number"></div>
</svg>
  2135   24 Mar 2021 Stefan RittBug ReportTime shift in history CSV export
I confirm there is a problem. If variables are from the same equipment, they have the same 
time stamps, like

t1 v1(t1) v2(t1)
t2 v1(t2) v2(t2)
t3 v1(t3) v2(t3)

when they are from different equipments, they have however different time stamps

t1 v1(t1)
t2    v2(t2)
t3 v1(t3)
t4    v2(t4)

The bug in the current code is that all variables use the time stamps of the first variable, 
which is wrong in the case of different equipments, like

t1 v1(t1) v2(*t2*)
t3 v1(t3) v2(*t4*)

So I can change the code, but I'm not sure what would be the bast way. The easiest would be to 
export one array per variable, like

t1 v1(t1)
t2 v1(t2)
...
t3 v2(t3)
t4 v2(t4)
...

Putting that into a single array would leave gaps, like

t1 v1(t1) [gap]
t2 [gap]  v2(t2)
t3 v1(t3) [gap]
t4 [ga]]  v2(t4)

plus this is programmatically more complicated, since I have to merge two arrays. So which 
export format would you prefer?

Stefan
  2151   13 Apr 2021 Stefan RittForumClient gets immediately removed when using a script button.
> I have followed your suggestions and the program still stops immediately. My status as returned from "cm_yield(100)" is always 412 (SS_TIMEOUT) which is fine. 
> The issue is that, when run with the script button, the do-wile loop stops immediately because the !ss_kbhit() always evaluates to FALSE.
> 
> My temporary solution has been to let the loop run forever :)

Ahh, could be that ss_kbhit() misbehaves if there is no keyboard, meaning that it is started in the background as a script. 
We never had the issue before, since all "standard" midas programs like mlogger, mhttpd etc. also use ss_kbhit() and they 
can be started in the background via the "-D" flag, but maybe the stdin is then handled differentlhy. 

So just remove the ss_kbhit(), but keep the break, so that you can stop your program via the web page, like

#include "midas.h"
#include "stdio.h"

int main() {
  cm_connect_experiment("", "", "logic_controller", NULL);

  do {
    int status = cm_yield(100);
    printf("cm_yield returned %d\n", status);
    if (status == SS_ABORT || status == RPC_SHUTDOWN)
      break;
  } while (TRUE);

  cm_disconnect_experiment();

  return 0;
}
  2152   14 Apr 2021 Stefan RittSuggestionTime zone selection for web page
> The new history as well as the clock in the web page header show the local time 
> of the user's computer running the browser.
> Would it be possible to make it either always use the time zone of the Midas 
> server, or make it selectable from the config page?
> It's not ideal trying to relate error messages from the midas.log to history 
> plots if the time stamps don't match.

I implemented a new row in the config page to select the time zone. 

"Local": Time zone where the browser runs
"Server": Time zone where the midas server runs (you have to update mhttpd for that)
"UTC+X": Any other time zone

The setting affects both the status header and the history display.

I spent quite some time with "named" time zones like "PST" "EST" "CEST", but the 
support for that is not that great in JavaScript, so I decided to go with simple 
UTC+X. Hope that's ok.

Please give it a try and let me know if it's working for you.

Best,
Stefan
Attachment 1: Screenshot_2021-04-14_at_16.54.12_.png
Screenshot_2021-04-14_at_16.54.12_.png
  2153   14 Apr 2021 Stefan RittInfoINT64/UINT64/QWORD not permitted in ODB and history... Change of TID_xxx data types
> These 64-bit data types do not work with ODB and they do not work with the MIDAS history.

They were never meant to work with the history. They were primarily implemented to put large 64-
bit data words into midas banks. We did not yet have a request to put these values into the ODB. 
Once such a request comes, we can address this.

Stefan
  2154   14 Apr 2021 Stefan RittBug ReportTime shift in history CSV export
I finally found some time to fix this issue in the latest commit. Please update and check if it's 
working for you.

Stefan
  2155   14 Apr 2021 Stefan RittBug ReportMinor bug: Change all time axes together doesn't work with +- buttons
> Version: release/midas-2020-12
> 
> In the new history display, the checkbox "Change all time axes together" works 
> well with the mouse-based zoom, but does not apply to the +- buttons.

Fixed in current commit.

Stefan
  2159   06 May 2021 Stefan RittForumm is not defined error
Thanks for reporting and pointing to the right location.

I fixed and committed it.

Best,
Stefan
  2162   10 May 2021 Stefan RittBug Reportmodbselect trigget hotlink
Thanks for reporting that bug, I fixed it in the last commit.

Stefan
  2165   12 May 2021 Stefan RittBug Reportmhttpd WebServer ODBTree initialization
> It looks like mhttpd managed to bind to the IPv4 address (localhost), but not the IPv6 address (::1). If you don't need it, try setting "/Webserver/Enable IPv6" to false.

We had this issue already several times. This info should be put into the documentation at a prominent location.

Stefan
  2168   14 May 2021 Stefan RittBug Reportmhttpd WebServer ODBTree initialization
> Thanks a lot, this solved my issue!

... or we should turn IPv6 off by default, since not many people use this right now.
  2179   28 May 2021 Stefan RittSuggestionHave a list of 'users responsible' in Alarms and Programs odb entries
I think this is a good idea and I support it. We have a similar problem in MEG and 
we solved that with external (bash) scripts called in case of alarms. One feature 
there we have is that for some alarms, several people want to get notified. So 
people can "subscribe" to certain alarms. The subscription are now handled inside 
Slack which I like better, but maybe it would be good to have more than one "user 
responsible". Like if one person is sleeping/traveling, it's good to have a 
substitute. Can you make an array out of that? Or a comma-separated list?

Best,
Stefan