We have an experiment that's been running for a long time and has some ODB keys that haven't been touched in ages. Mostly related to features that we don't use like the elog and lazylogger, or things that don't change often (like the logger data directory).
When we start any program, we now got dozens of error messages in the log with lines like:
hkey 297088, path "/Elog/Display run number", invalid pkey->last_written time 1377040124
That timestamp is reasonable though, as the experiment was set up in 2013!
What's the best way to make these messages go away?
- Change the logic in db_validate_and_repair_key_wlocked() to not worry if keys are 10+ years old?
- Write a script to "touch" all the old keys so they've been modified recently?
- Something else? |
2681
|
18 Jan 2024 |
Stefan Ritt | Forum | mhttpd eqtable |
I fixed both in the current version, so please give it a try.
Stefan |
2680
|
18 Jan 2024 |
Stefan Ritt | Forum | History tags |
This part of the system has been designed by KO, so he should reply here.
Stefan |
2679
|
18 Jan 2024 |
Andreas Suter | Forum | mhttpd eqtable |
I have two more questions related to Units, Format for Equipment/Settings:
1) It looks as if I can have units per channel only for the Input/Output channels but not for Demand/Measured channels.
For instance we do have HV FE which collect devices with kV and V demand settings. It looks like this is not possible (see attachment) to have per channel units.
Is this right, or do I miss something here?
2) This new functionality needs entries under /Equipment/<eq-name>/Settings. The class driver generates the necessary structures if they are missing at the startup
of the scfe. It would be nice that the new, additional entries would be generate as well: Editable, Unit Input, Unit Format, etc. Perhaps optionally, if a DD is providing it?
Best,
Andreas |
Attachment 1: hv-web.png
|
|
2678
|
17 Jan 2024 |
Andreas Suter | Bug Report | mhttpd eqtable |
Great! This is it.
Sorry that I missed it in the docu.
Best,
Andreas |
2677
|
17 Jan 2024 |
Pavel Murat | Forum | a scroll option for "add history variables" window? |
> Have you updated to the current midas version? This issue has been fixed a while ago.
Hi Stefan, thanks a lot! I pulled from the head, and the scrolling works now. -- regards, Pasha |
2676
|
17 Jan 2024 |
Francesco Renga | Forum | History tags |
Dear experts,
I would like to have some clarification about the meaning and use of the
tags in the ODB under /History/Tags.
I noticed that, if a history plot is created, but the name of the corresponding
variable is changed later and the plot is modified accordingly, the old name
persists in the /History/Tags list along with the new one. So, it appears in the
list of variables when a new history plot is created.
It seems not to compromise the functionalities of the history system, but it is
prone to create confusion.
Is it the expected behavior? What is the correct procedure to follow if the name
of a variable has to be changed?
Thank you,
Francesco |
2675
|
17 Jan 2024 |
Stefan Ritt | Bug Report | mhttpd eqtable |
> 1) In the attached snapshot you see that the values shown from our vacuum Pirani and Penning cells are all zero, which of course is not true.
> It would be nice to have under the equipment settings some formatting options, like the possibility to add units.
You have a
/Equipment/LEMVAC/Settings/Format Input
array where you can specify the format for every value. Default is "%f2" for two digits after the period. For vacuum levels you might want to
consider "%e3" which give you exponential format with three significant digits. The "format" setting is described at
https://daq00.triumf.ca/MidasWiki/index.php//Equipment_ODB_tree#Format_%3Cvariable%3E
and the details are at
https://daq00.triumf.ca/MidasWiki/index.php/Custom_Page#Formatting
The was a bug with the format handling, so please pull the current develop branch.
> 2) If one of the number evaluates to Infinity, the table is not shown properly anymore.
I fixed that as well in the current version.
Best,
Stefan |
Attachment 1: Screenshot_2024-01-17_at_14.09.30.png
|
|
2674
|
17 Jan 2024 |
Andreas Suter | Bug Report | mhttpd eqtable |
Hi,
I like the new eqtable, but stumbled over some issues.
1) In the attached snapshot you see that the values shown from our vacuum Pirani and Penning cells are all zero, which of course is not true.
It would be nice to have under the equipment settings some formatting options, like the possibility to add units.
2) If one of the number evaluates to Infinity, the table is not shown properly anymore.
Best,
Andreas |
Attachment 1: midas-eqtable.png
|
|
2673
|
16 Jan 2024 |
Stefan Ritt | Forum | a scroll option for "add history variables" window? |
Have you updated to the current midas version? This issue has been fixed a while ago. Below
you see a screenshot of a long list scrolled all the way to the bottom.
Revision: Thu Dec 7 14:26:37 2023 +0100 - midas-2022-05-c-762-g1eb9f627-dirty on branch
develop
Chrome on MacOSX 14.2.1
The fix is actually in "controls.js", so make sure your browser does not cache an old
version of that file. I usually have to clear my browser history to get the new file from
mhttpd.
Best regards,
Stefan |
Attachment 1: Screenshot_2024-01-17_at_08.17.30.png
|
|
2672
|
16 Jan 2024 |
Pavel Murat | Forum | a scroll option for "add history variables" window? |
Dear all,
I have a "slow control" frontend which reads out 100 slow control parameters.
When I'm interactively adding a parameter to a history plot,
a nice "Add history variable" pops up .. , but with 100 parameters in the list,
it doesn't fit within the screen...
The browser becomes passive, and I didn't find any easy way of scrolling.
In the attached example, adding a channel 32 variable becomes rather cumbersome,
not speaking about channel 99.
Two questions:
a) how do people get around this "no-scrolling" issue? - perhaps there is a workaround
b) how big of a deal is it to add a scroll bar to the "Add history variables" popup ?
- I do not know javascript myself, but could find help to contribute..
-- many thanks, regards, Pasha |
Attachment 1: adding_a_variable_to_the_history_plot.png
|
|
2671
|
15 Jan 2024 |
Frederik Wauters | Forum | dump history FILE files |
We switched from the history files from MIDAS to FILE, so we have *.dat files now (per variable), instead of the old *.hst.
How shoul
d one now extract data from these data files? With the old *,hst files I can e.g. mhdump -E 102 231010.hst
but with the new *.dat files I get
...2023/history$ mhdump -E 0 -T "Run number" mhf_1697445335_20231016_run_transitions.dat | head -n 15
event name: [Run transitions], time [1697445335]
tag: tag: /DWORD 1 4 /timestamp
tag: tag: UINT32 1 4 State
tag: tag: UINT32 1 4 Run number
record size: 12, data offset: 1024
record 0, time 1697557722, incr 112387
record 1, time 1697557783, incr 61
record 2, time 1697557804, incr 21
record 3, time 1697557834, incr 30
record 4, time 1697557888, incr 54
record 5, time 1697558318, incr 430
record 6, time 1697558323, incr 5
record 7, time 1697558659, incr 336
record 8, time 1697558668, incr 9
record 9, time 1697558753, incr 85
not very intelligible
Yes, I can do csv export on the webpage. But it would be nice to be able to extract from just the files. Also, the webpage export only saves the data shown ( range limited and/or downsampled) |
2670
|
12 Jan 2024 |
Stefan Ritt | Forum | slow control frontends - how much do they sleep and how often their drivers are called? |
> Hi Stefan, thanks a lot !
>
> I just thought that for the EQ_SLOW type equipment calls to sleep() could be hidden in mfe.cxx
> and handled based on the requested frequency of the history updates.
Most people combine EQ_SLOW with EQ_POLLED, so they want to read out as quickly as possible. Since
the framework cannot "guess" what the users want there, I removed all sleep() in the framework.
> Doing the same in the user side is straighforward - the important part is to know where the
> responsibility line goes (: smile :)
Pushing this to the user gives you more freedom. Like you can add sleep() for some frontends, but not
for others, only when the run is stopped and more.
Stefan |
2669
|
11 Jan 2024 |
Pavel Murat | Forum | slow control frontends - how much do they sleep and how often their drivers are called? |
Hi Stefan, thanks a lot !
I just thought that for the EQ_SLOW type equipment calls to sleep() could be hidden in mfe.cxx
and handled based on the requested frequency of the history updates.
Doing the same in the user side is straighforward - the important part is to know where the
responsibility line goes (: smile :)
-- regards, Pasha |
2668
|
11 Jan 2024 |
Stefan Ritt | Forum | slow control frontends - how much do they sleep and how often their drivers are called? |
Put a
ss_sleep(10);
into your frontend_loop(), then you should be fine.
The event loop runs as fast as possible in order not to miss any (triggered) event, so no seep in the
event loop, because this would limit the (triggered) event rate to 100 Hz (minimum sleep is 10 ms).
Therefore, you have to slow down the event loop manually with the method described above.
Best,
Stefan |
2667
|
10 Jan 2024 |
Pavel Murat | Forum | slow control frontends - how much do they sleep and how often their drivers are called? |
Dear all,
I have implemented a number of slow control frontends which are directed to update the
history once in every 10 sec, and they do just that.
I expected that such frontends would be spending most of the time sleeping and waking up
once in ten seconds to call their respective drivers and send the data to the server.
However I observe that each frontend process consumes almost 100% of a single core CPU time
and the frontend driver is called many times per second.
Is that the expected behavior ?
So far, I couldn't find the place in the system part of the frontend code (is that the right
place to look for?) which regulates the frequency of the frontend driver calls, so I'd greatly
appreciate if someone could point me to that place.
I'm using the following commit:
commit 30a03c4c develop origin/develop Make sure line numbers and sequence lines are aligned.
-- many thanks, regards, Pasha |
2666
|
03 Jan 2024 |
Konstantin Olchanski | Forum | midas.triumf.ca alias moved to daq00.triumf.ca |
> I found the first issue: The link to
> https://midas.triumf.ca/MidasWiki/index.php/Custom_plots_with_mplot
fixed.
https://midas.triumf.ca/Custom_plots_with_mplot
also works.
I tried to get rid of redirect to daq00 completely and make the whole MidasWiki show up
under midas.triumf.ca, but discovered/remembered that I cannot do this without changing
MidasWiki config [$wgServer = "https://daq00.triumf.ca";] which causes mediawiki to
redirect everything to daq00 (using the 301 "moved permanently" reply, ouch!). In theory,
if I change it to "https://midas.triumf.ca" it will redirect everything there instead,
but I am hesitant to make this change. It has been like this since forever and I have no
idea what else will break if I change it.
K.O. |
2665
|
03 Jan 2024 |
Stefan Ritt | Bug Report | Compilation error on RPi |
> > git pull
> > git submodule update
>
> confirmed. just run into this myself. I think "make" should warn about out of
> date git modules. Also check that the build git version is tagged with "-dirty".
>
> K.O.
The submodule business becomes kind of annoying. I updated the documentation at
https://daq00.triumf.ca/MidasWiki/index.php/Quickstart_Linux#MIDAS_Package_Installatio
n
to tell people to use
1) "git clone ... --recurse-submodules" during the first clone
2) "git submodule update --init --recursive" in case they forgot 1)
3) "git pull --recurse-submodules" for each update or to use
4) "git config submodule.recurse true" to make the --recurse-submodules the default
I use 4) since a while and it works nicely, so one does not have to remember to pull
recursively each time.
Stefan |
2664
|
03 Jan 2024 |
Stefan Ritt | Forum | midas.triumf.ca alias moved to daq00.triumf.ca |
> the DNS alias for midas.triumf.ca moved from old ladd00.triumf.ca to new
> daq00.triumf.ca. same as before it redirects to the MidasWiki and to the midas
> forum (elog) that moved from ladd00 to daq00 quite some time ago. if you see any
> anomalies in accessing them (broken links, bad https certificates), please report
> them to this forum or to me directly at olchansk@triumf.ca. K.O.
I found the first issue: The link to
https://midas.triumf.ca/MidasWiki/index.php/Custom_plots_with_mplot
does not work any more. The link
https://daq00.triumf.ca/MidasWiki/index.php/Custom_plots_with_mplot
however does work. Same with
https://midas.triumf.ca/MidasWiki/index.php/Sequencer
and
https://daq00.triumf.ca/MidasWiki/index.php/Sequencer
I have a few cases in mhttpd where I link directly to our documentation. I prefer
to have those link with "midas.triumf.ca" instead of "daq00.triumf.ca" in case you
change the machine again in the future.
Best,
Stefan |
2663
|
02 Jan 2024 |
Konstantin Olchanski | Forum | midas.triumf.ca alias moved to daq00.triumf.ca |
the DNS alias for midas.triumf.ca moved from old ladd00.triumf.ca to new
daq00.triumf.ca. same as before it redirects to the MidasWiki and to the midas
forum (elog) that moved from ladd00 to daq00 quite some time ago. if you see any
anomalies in accessing them (broken links, bad https certificates), please report
them to this forum or to me directly at olchansk@triumf.ca. K.O. |