2966
20 Mar 2025
Konstantin Olchanski
Bug Report
please fix mscb compiler warning
I am getting a scary compiler warning from
MSCB code. I generally avoid touching MSCB
code because I have no MSCB hardware to test
2972
20 Mar 2025
Konstantin Olchanski
Bug Report
Default write cache size for new equipments breaks compatibility with older equipments
I think I added the cache size correctly:
{"Trigger", /* equipment
2973
20 Mar 2025
Konstantin Olchanski
Bug Report
Default write cache size for new equipments breaks compatibility with older equipments
the main purpose of the event buffer write
cache is to prevent high contention for the
2974
20 Mar 2025
Konstantin Olchanski
Bug Report
Default write cache size for new equipments breaks compatibility with older equipments
> the main purpose of the event buffer write
cache
2975
20 Mar 2025
Konstantin Olchanski
Bug Report
Default write cache size for new equipments breaks compatibility with older equipments
> > the main purpose of the event buffer write
cache
> how to control the write cache size:
2977
20 Mar 2025
Konstantin Olchanski
Bug Report
manalyzer module init order problem
Andrea Capra reported a problem with manalyzer
module initialization order.
2978
21 Mar 2025
Jonas A. Krieger
Bug Report
midas equipment "format"
Hi Konstantin,
In the PSI muSR laboratory, we are running
2979
21 Mar 2025
Stefan Ritt
Bug Report
Default write cache size for new equipments breaks compatibility with older equipments
> All this is kind of reasonable, as only
two settings of write cache size are useful:
0 to
2985
21 Mar 2025
Stefan Ritt
Bug Report
please fix compiler warning
> Unnamed person who added this clever bit
of c++ coding, please fix this compiler warning.
Stock g++ on Ubuntu LTS 24.04. Thanks in
2989
21 Mar 2025
Stefan Ritt
Bug Report
please fix mscb compiler warning
I hopefully fixed the waring (narrowing down
from size_t to int). Please double check
with your compiler.
2998
25 Mar 2025
Konstantin Olchanski
Bug Report
midas equipment "format"
> In the PSI muSR laboratory, we are running
about 140 slow control devices across six
instruments using Format FIXED.
2999
25 Mar 2025
Konstantin Olchanski
Bug Report
manalyzer module init order problem
> Andrea Capra reported a problem with manalyzer
module initialization order.
3002
25 Mar 2025
Konstantin Olchanski
Bug Report
please fix compiler warning
Confirming warning is fixed. Thanks! K.O.
> > Unnamed person who added this clever
3003
25 Mar 2025
Konstantin Olchanski
Bug Report
please fix mscb compiler warning
> I hopefully fixed the waring (narrowing
down from size_t to int). Please double check
with your compiler.
3004
25 Mar 2025
Konstantin Olchanski
Bug Report
Default write cache size for new equipments breaks compatibility with older equipments
> > All this is kind of reasonable, as only
two settings of write cache size are useful:
0 to
3012
01 Apr 2025
Pavel Murat
Bug Report
MIDAS history system not using the event timestamps ?
Dear MIDAS experts,
I confirm that when writing out history files
3018
01 Apr 2025
Konstantin Olchanski
Bug Report
ODB corruption
We see ODB corruption crashes in the DS20k
vertical slice MIDAS instance.
3020
01 Apr 2025
Konstantin Olchanski
Bug Report
MIDAS history system not using the event timestamps ?
> I confirm that when writing out history
files corresponding to the slow control event
data,
3022
02 Apr 2025
Pavel Murat
Bug Report
MIDAS history system not using the event timestamps ?
> You can always include your "true" data
timestamp as the first value in your data.
3023
02 Apr 2025
Konstantin Olchanski
Bug Report
MIDAS history system not using the event timestamps ?
> > You can always include your "true" data
timestamp as the first value in your data.
>