  2008   21 Oct 2020 Soichiro KuribayashiInfoAbout remote control of front end part of MIDAS on chipDear Stefan,

Thank you very much for your help.
  
  2007   20 Oct 2020 Stefan RittInfoAbout remote control of front end part of MIDAS on chipWe also use a Zynq chip and boot in the following
order:
  
  2006   13 Oct 2020 Soichiro KuribayashiInfoAbout remote control of front end part of MIDAS on chipDear Konstantin,

Thank you very much for your reply and detailed
  
  2005   13 Oct 2020 Konstantin OlchanskiInfoAbout remote control of front end part of MIDAS on chip> My name is Soichiro Kuribayashi and I am
a Ph.D. student at Kyoto University. 
> I'm a T2K collaborator and working for
  
  2004   13 Oct 2020 Soichiro KuribayashiInfoAbout remote control of front end part of MIDAS on chipHello!

My name is Soichiro Kuribayashi and I am
  
  2002   06 Oct 2020 Konstantin OlchanskiForumusing python client to start and stop run> The ODB variable "/Runinfo/State" is a symptom
of starting/stopping a run, rather than the
cause.
  
  2001   29 Sep 2020 Ben SmithForumusing python client to start and stop runThe ODB variable "/Runinfo/State" is a symptom
of starting/stopping a run, rather than the
cause.
  
  2000   29 Sep 2020 Amy RobertsForumusing python client to start and stop runI'm using a python client to start and stop
runs, and the following code *appears* 
to set the MIDAS state to "Run"
  
  1999   24 Sep 2020 Gennaro TortoneForumsubrun Hi,

I was wondering if there is a "mechanism"
  
  1998   22 Sep 2020 Konstantin OlchanskiForumINT INT32 in experim.h> For my analyzer I generate the experim.h
file from the odb.
  
  1997   22 Sep 2020 Frederik WautersForumINT INT32 in experim.hFor my analyzer I generate the experim.h file
from the odb.
  
  1996   08 Sep 2020 Ruslan PodviianiukForumTransition status message> > > The information you want is in the ODB:
> > > * "/System/Transition/status" is the
overall integer status code.
  
  1995   08 Sep 2020 Konstantin OlchanskiForumTransition status message> > The information you want is in the ODB:
> > * "/System/Transition/status" is the
overall integer status code.
  
  1994   08 Sep 2020 Konstantin OlchanskiForumjson parser error> I am getting the following error alert in
a custom page whenever a run starts
> json parser exception: SyntaxError: Unexpected
  
  1993   08 Sep 2020 Zaher SalmanForumjson parser errorI am getting the following error alert in
a custom page whenever a run starts
  
  1992   02 Sep 2020 Ruslan PodviianiukForumTransition status message> The information you want is in the ODB:
> * "/System/Transition/status" is the overall
integer status code.
  
  1991   02 Sep 2020 Ben SmithForumTransition status messageThe information you want is in the ODB:
* "/System/Transition/status" is the overall
integer status code.
  
  1990   02 Sep 2020 Ruslan PodviianiukForumTransition status messageHello,

I got an error after start of run and it
 issue.png 
  Draft   25 Aug 2020 Ruslan PodviianiukForumtime information Thank you, Stefan

 >>>var d = new Date(start_time_binary);
  
  1988   25 Aug 2020 Ruslan PodviianiukForumtime informationThank you, Stefan