2670
|
12 Jan 2024 |
Stefan Ritt | Forum | slow control frontends - how much do they sleep and how often their drivers are called? |
> Hi Stefan, thanks a lot !
>
> I just thought that for the EQ_SLOW type equipment calls to sleep() could be hidden in mfe.cxx
> and handled based on the requested frequency of the history updates.
Most people combine EQ_SLOW with EQ_POLLED, so they want to read out as quickly as possible. Since
the framework cannot "guess" what the users want there, I removed all sleep() in the framework.
> Doing the same in the user side is straighforward - the important part is to know where the
> responsibility line goes (: smile :)
Pushing this to the user gives you more freedom. Like you can add sleep() for some frontends, but not
for others, only when the run is stopped and more.
Stefan |
2673
|
16 Jan 2024 |
Stefan Ritt | Forum | a scroll option for "add history variables" window? |
Have you updated to the current midas version? This issue has been fixed a while ago. Below
you see a screenshot of a long list scrolled all the way to the bottom.
Revision: Thu Dec 7 14:26:37 2023 +0100 - midas-2022-05-c-762-g1eb9f627-dirty on branch
develop
Chrome on MacOSX 14.2.1
The fix is actually in "controls.js", so make sure your browser does not cache an old
version of that file. I usually have to clear my browser history to get the new file from
mhttpd.
Best regards,
Stefan |
2675
|
17 Jan 2024 |
Stefan Ritt | Bug Report | mhttpd eqtable |
> 1) In the attached snapshot you see that the values shown from our vacuum Pirani and Penning cells are all zero, which of course is not true.
> It would be nice to have under the equipment settings some formatting options, like the possibility to add units.
You have a
/Equipment/LEMVAC/Settings/Format Input
array where you can specify the format for every value. Default is "%f2" for two digits after the period. For vacuum levels you might want to
consider "%e3" which give you exponential format with three significant digits. The "format" setting is described at
https://daq00.triumf.ca/MidasWiki/index.php//Equipment_ODB_tree#Format_%3Cvariable%3E
and the details are at
https://daq00.triumf.ca/MidasWiki/index.php/Custom_Page#Formatting
The was a bug with the format handling, so please pull the current develop branch.
> 2) If one of the number evaluates to Infinity, the table is not shown properly anymore.
I fixed that as well in the current version.
Best,
Stefan |
2680
|
18 Jan 2024 |
Stefan Ritt | Forum | History tags |
This part of the system has been designed by KO, so he should reply here.
Stefan |
2681
|
18 Jan 2024 |
Stefan Ritt | Forum | mhttpd eqtable |
I fixed both in the current version, so please give it a try.
Stefan |
2683
|
22 Jan 2024 |
Stefan Ritt | Bug Report | Warnings about ODB keys that haven't been touched for 10+ years |
> What's the best way to make these messages go away?
> - Change the logic in db_validate_and_repair_key_wlocked() to not worry if keys are 10+ years old?
> - Write a script to "touch" all the old keys so they've been modified recently?
> - Something else?
The function db_validate_and_repair_key_wlocked() has been written by KO so he should reply here.
In my opinion, I would go with the first one. Changing the function is easier than to write a script
and teach everybody how to use it. This would be one more thing not to forget.
Now changing the function is not so obvious. We could extend the check to let's say 20 years, but
then we meet here again in ten years. Maybe the best choice would be to just check that the time
is not in the future.
Anyhow, most people don't realize, but we all will have fun on Jan 19, 2038, when the Unix time
overflows in 32-bit signed integers. I don't know if midas will be around by then (I will be 74 years),
but before that date one has to worry about many places in midas where we use Unix time. At that time
your date stamps from 2013 would be 25 years old, so we either remove the date check (just keep
the check of not being in the future), or extend it to 26 years.
Stefan |
2694
|
28 Jan 2024 |
Stefan Ritt | Forum | number of entries in a given ODB subdirectory ? |
I guess you won't change your FPGA configuration just when you start a run, so I don't consider the race
condition very crucial (although KO is correct, it it there).
I guess rather than any pseudo code you want to see real working code (db_get_num_entries() does not exist!), right?
The easiest these day is to ask ChatGPT. MIDAS has been open source since a long time, so it has been used
to train modern Large Language Models. Attached is the result. Here is the direct link from where you can
copy the code:
https://chat.openai.com/share/d927c78d-9914-4413-ab5e-3b0e5d173132
Please note that you never can be 100% sure that the code from a LLM is correct, so always compile and debug it.
But nevertheless, it's always easier to start from some existing code, even if there is a danger that it's not perfect.
Best,
Stefan |
2695
|
28 Jan 2024 |
Stefan Ritt | Bug Report | Warnings about ODB keys that haven't been touched for 10+ years |
> Please run "git blame" to find out who added that check.
OK ok, was me. But actually 2003. I hope that this being more than 20y ago excuses me not remembering it ;-)
> I think this age check should be removed, but there must be *some* check for invalid/bogus timestamps. Or
> not, we should check if MIDAS cares about timestamps at all, if ODB functions never use/look at timestamp,
> maybe we are okey with bogus timestamps. They may look funny in the odb editor, but that's it.
I changed the code to only check for timestamps more than 1h in the future and then complain. This should
avoid glitches when switching daylight savings time.
Stefan |
2705
|
08 Feb 2024 |
Stefan Ritt | Forum | number of entries in a given ODB subdirectory ? |
> Konstantin is right: KEY.num_values is not the same as the number of subkeys (should it be ?)
For ODB keys of type TID_KEY, the value num_values IS the number of subkeys. The only issue here is
what KO mentioned already. If you obtain num_values, start iterating, then someone else might
change the number of subkeys, then your (old) num_values is off. Therefore it's always good to
check the return status of all subkey accesses. To do a truely atomic access to a subtree, you need
db_copy(), but then you have to parse the JSON yourself, and again you have no guarantee that the
ODB hasn't changed in meantime.
Stefan |
2708
|
13 Feb 2024 |
Stefan Ritt | Forum | number of entries in a given ODB subdirectory ? |
> > For ODB keys of type TID_KEY, the value num_values IS the number of subkeys.
>
> this logic makes sense, however it doesn't seem to be consistent with the printout of the test example
> at the end of https://daq00.triumf.ca/elog-midas/Midas/240203_095803/a.cc . The printout reports
>
> key.num_values = 1, but the actual number of subkeys = 6, and all subkeys being of TID_KEY type
>
> I'm certain that the ODB subtree in question was not accessed concurrently during the test.
You are right, num_values is always 1 for TID_KEYS. The number of subkeys is stored in
((KEYLIST *) ((char *)pheader + pkey->data))->num_keys
Maybe we should add a function to return this. But so far db_enum_key() was enough.
Stefan |
2715
|
15 Feb 2024 |
Stefan Ritt | Forum | number of entries in a given ODB subdirectory ? |
> Hmm... is there any use case where you want to know the number of directory entries, but you will not iterate
> over them later?
I agree.
One more way to iterate over subkeys by name is by using the new odbxx API:
midas::odb tree("/Test/Settings");
for (midas::odb& key : tree)
std::cout << key.get_name() << std::endl;
Stefan |
2720
|
27 Feb 2024 |
Stefan Ritt | Forum | displaying integers in hex format ? |
Thanks for reporting that bug. I fixed it and committed the change to the develop branch.
Stefan |
2737
|
15 Apr 2024 |
Stefan Ritt | Bug Report | open MIDAS RPC ports |
One thing coming to my mind is the interface binding. If you have a midas host with two networks
("global" and "local"=192.168.x.x), you can tell to which interface a socket should bind.
By default it binds both interfaces, but we could restrict the socket only to bind to the local
interface 192.168.x.x. This way the open port would be invisible from the outside, but from
your local network everybody can connect easily without the need of a white list.
Stefan |
2741
|
29 Apr 2024 |
Stefan Ritt | Forum | Midas Sequencer with less than 1 second wait |
I guess the simplest way to do that without breaking with existing code is to change the
second number to a float. So a
WAIT SECONDS, 1
will still work, and you can then write
WAIT SECONDS, 0.01
to get a 10 ms wait. Would that work for you?
Stefan |
2744
|
30 Apr 2024 |
Stefan Ritt | Forum | Midas Sequencer with less than 1 second wait |
> This would work fine in principle, but isn't implemented in the current MIDAS sequencer as we understand it. (We tried!) Is your proposal to rewrite the sequencer
> to allow fractional waits? Right now the code seems to store the start_time as a DWORD and uses atoi to parse the wait time, and uses ss_time (which seems only get
> the time to the nearest second) to fetch the time.
No it's not implemented, was just my idea. If it would work for you, I can implement it in the next couple of days.
Stefan |
2746
|
30 Apr 2024 |
Stefan Ritt | Forum | Midas Sequencer with less than 1 second wait |
While I will do it, i'm not sure if this is what you want. If I understand correctly, some process gets triggered and then writes some values to the ODB, then the sequencer
should continue. Putting a wait there is dangerous. Maybe your process always takes like 10-20 ms, so you put a wait of let's say 100ms, and things are fine with you. Your
script runs many days, but then once in a while your machine is on heavy load because someone starts a web browser, and your process takes 110ms, and you script crashes.
I would rather go following path: put a "done" flag in the ODB, which is the last one which gets set by your process. Then the sequencer does a
WAIT ODBvalue, /path/value, =, 1
which will work always, independend of the delay of your process.
Stefan |
2748
|
02 May 2024 |
Stefan Ritt | Forum | Midas Sequencer with less than 1 second wait |
Ok, I implemented the float second wait function. Internally it works in ms, so the maximum resolution is 0.001 s.
Best,
Stefan |
2751
|
03 May 2024 |
Stefan Ritt | Bug Report | Params not initialized when starting sequencer |
Ok, here is the complete code to reproduce the problem. Load parameter_test.msl which includes functions.msl. From the screenshot you see the variables containing
garbage, and you also see that from the ODB screenshot. For completeness, I added Sequencer.json which contains the whole sequencer tree.
The interesting thing is that this works sometimes, and sometimes not. I'm not sure if this in the GUI or in the sequencer program, so we have to sort out who can
fix it ;-)
Best,
Stefan |
2754
|
03 May 2024 |
Stefan Ritt | Suggestion | Possible addition to IF Statements |
The tinyexpr library I use to evaluate expressions does not support boolean operations. I would have to switch to the newer
tineyexpr-plusplus version, which also has much richer functionality:
https://github.com/Blake-Madden/tinyexpr-plusplus/blob/tinyexpr%2B%2B/TinyExprChanges.md
Unfortunately it requires C++17, and at the moment we limit MIDAS to C++11, meaning we would break this requirement. I
believe at the moment there are still some experiments (mainly at TRIUMF) which are stuck to older OS and therefore cannot
switch to C++17, but hopefully this will change over time.
Stefan |
2756
|
03 May 2024 |
Stefan Ritt | Bug Report | Params not initialized when starting sequencer |
Ahh, that rings a bell:
1) JS opens start dialog box
2) User enters parameters and presses start
3) JS writes parameters
4) JS starts sequencer
5) Sequencer copies parameters to variables
Now how do you handle 3) and 4). Just issue two mjsonrpc commands together? What then could happen is that 4) is executed before 3) and we get the garbage.
You have to do 3) and WAIT for the return ("then" in the JS promise), and only then issue 4) from there.