ID |
Date |
Author |
Topic |
Subject |
Text |
 |
2910
|
01 Dec 2024 |
Stefan Ritt | Bug Report | EQ_PERIODIC-only equipment ? | There is no requirement that you pair an EQ_PERIODIC
with an EQ_TRIGGER. Take for exmaple
|
|
2912
|
02 Dec 2024 |
Stefan Ritt | Bug Report | ODB key picker does not close when creating link / Edit-on-run string box too large | > Actual result:
> The key picker does not close.
|
|
2913
|
02 Dec 2024 |
Stefan Ritt | Bug Report | ODB key picker does not close when creating link / Edit-on-run string box too large | > Another more minor visual problem is the
edit-on-start dialog. There seems to be no
upper bound to the
|
|
2914
|
02 Dec 2024 |
Stefan Ritt | Forum | "Safe" abort of sequencer scripts | The atexit() function has been implemented
in the current develop branch of midas, see
|
|
2917
|
06 Dec 2024 |
Stefan Ritt | Info | New slow control framework "mdev" | A new slow control mini-framework has been
developed for MIDAS and been successfully
tested in the Mu3e experiment. It
|
|
2920
|
10 Dec 2024 |
Stefan Ritt | Suggestion | Comma-separated indices in alarm conditions | These kind of alarm conditions have been implemented
and committed. The documentation at
|
|
2921
|
12 Dec 2024 |
Stefan Ritt | Suggestion | New alarm sound flag to be tested | We had the case in MEG that some alarms were
actually just warnings, not very severe.
This happens for example if we calibrate |
|
2924
|
19 Dec 2024 |
Stefan Ritt | Bug Report | [History plots] "Jump to current time" resets x range to 7d | I had put in a check which limits the range
to 7d into the past if you press the "play"
button, but now I'm not sure why this was |
|
2925
|
19 Dec 2024 |
Stefan Ritt | Suggestion | New alarm count added | Another modification has been done to the
alarm system.
|
|
2929
|
05 Jan 2025 |
Stefan Ritt | Forum | time ordering of run transition calls to TMFeEquipment things | Hi Pavel,
have you looked into
|
|
2931
|
09 Jan 2025 |
Stefan Ritt | Suggestion | improved find_package behaviour for Midas | After some iterations, we merged the branch
with the new build scheme. Now you can compile
any midas program as described at
|
|
2944
|
24 Feb 2025 |
Stefan Ritt | Bug Report | Default write cache size for new equipments breaks compatibility with older equipments | The commit that introduced the write cache
size check is https://bitbucket.org/tmidas/midas/commits/3619ecc6ba1d29d74c16aa6571e40920018184c0
|
|
2979
|
21 Mar 2025 |
Stefan Ritt | Bug Report | Default write cache size for new equipments breaks compatibility with older equipments | > All this is kind of reasonable, as only
two settings of write cache size are useful:
0 to
|
|
2980
|
21 Mar 2025 |
Stefan Ritt | Suggestion | BINARY INCOMPATIBLE CHANGE: New alarm count added | > > ALL MIDAS CLIENTS GET RE-COMPILED after
the new code is applied.
>
|
|
2985
|
21 Mar 2025 |
Stefan Ritt | Bug Report | please fix compiler warning | > Unnamed person who added this clever bit
of c++ coding, please fix this compiler warning.
Stock g++ on Ubuntu LTS 24.04. Thanks in |
|
2988
|
21 Mar 2025 |
Stefan Ritt | Bug Fix | bitbucket builds fixed | > bitbucket automatic builds were broken after
mfe.cxx started printing some additional
messages added in commit
|
|
2989
|
21 Mar 2025 |
Stefan Ritt | Bug Report | please fix mscb compiler warning | I hopefully fixed the waring (narrowing down
from size_t to int). Please double check
with your compiler.
|
|
2990
|
21 Mar 2025 |
Stefan Ritt | Forum | LabView-Midas interface | > Hello,
>
> Does anyone have experience with writing |
|
3015
|
01 Apr 2025 |
Stefan Ritt | Suggestion | Sequencer ODBSET feature requests | A new sequencer which understands Python is
in the works. There you can use all features
from that language.
|
|
3016
|
01 Apr 2025 |
Stefan Ritt | Suggestion | Sequencer ODBSET feature requests | The extended ODBSET[x,y1-y2,z] could make
sense to be implemented, since it then will
match the alarm system which uses the same |
|