Entry  16 Jan 2024, Pavel Murat, Forum, a scroll option for "add history variables" window? adding_a_variable_to_the_history_plot.png
Dear all,

I have a "slow control" frontend which reads out 100 slow control parameters.
    Reply  16 Jan 2024, Stefan Ritt, Forum, a scroll option for "add history variables" window? Screenshot_2024-01-17_at_08.17.30.png
Have you updated to the current midas version? This issue has been fixed a while ago. Below 
you see a screenshot of a long list scrolled all the way to the bottom.
       Reply  17 Jan 2024, Pavel Murat, Forum, a scroll option for "add history variables" window? 
> Have you updated to the current midas version? This issue has been fixed a while ago. 

Hi Stefan, thanks a lot! I pulled from the head, and the scrolling works now. -- regards, Pasha
          Reply  28 Jan 2024, Konstantin Olchanski, Forum, a scroll option for "add history variables" window? 
> > Have you updated to the current midas version? This issue has been fixed a while ago. 

> Hi Stefan, thanks a lot! I pulled from the head, and the scrolling works now. -- regards, Pasha
             Reply  29 Jan 2024, Pavel Murat, Forum, a scroll option for "add history variables" window? 
> If you have some ideas on how to better present 100500 history variables, please shout out!

let me share some thoughts. In a particular case which lead to the original posting, 
                Reply  29 Jan 2024, Konstantin Olchanski, Forum, a scroll option for "add history variables" window? 
familiar situation, "too much data", you dice t or slice it, still too much. BTW, you can try to generate history 
plot ODB entries from your program instead of from the history plot editor. K.O.
Entry  22 Jan 2024, Ben Smith, Bug Report, Warnings about ODB keys that haven't been touched for 10+ years 
We have an experiment that's been running for a long time and has some ODB keys that haven't been touched in ages. Mostly related to features that we don't
use like the elog and lazylogger, or things that don't change often (like the logger data directory).
    Reply  22 Jan 2024, Stefan Ritt, Bug Report, Warnings about ODB keys that haven't been touched for 10+ years 
> What's the best way to make these messages go away? 
> - Change the logic in db_validate_and_repair_key_wlocked() to not worry if keys are 10+ years old? 
> - Write a script to "touch" all the old keys so they've been modified recently?
    Reply  23 Jan 2024, Nick Hastings, Bug Report, Warnings about ODB keys that haven't been touched for 10+ years 
Hi,

> What's the best way to make these messages go away? 
       Reply  24 Jan 2024, Pavel Murat, Bug Report, Warnings about ODB keys that haven't been touched for 10+ years 
I don't immediately see a reason for saying that if a DB key is older than 10 yrs, it may not be valid.

However, it would be worth learning what was the logic behind choosing 10 yrs as a threshold. 
          Reply  28 Jan 2024, Konstantin Olchanski, Bug Report, Warnings about ODB keys that haven't been touched for 10+ years 
> I don't immediately see a reason for saying that if a DB key is older than 10 yrs, it may not be valid.

> However, it would be worth learning what was the logic behind choosing 10 yrs as a threshold. 
             Reply  28 Jan 2024, Stefan Ritt, Bug Report, Warnings about ODB keys that haven't been touched for 10+ years 
> Please run "git blame" to find out who added that check.

OK ok, was me. But actually 2003. I hope that this being more than 20y ago excuses me not remembering it ;-)
Entry  11 Dec 2023, Pavel Murat, Forum, the logic of handling history variables ? 11x
Dear MIDAS developers,

I'm trying to understand handling of the history (slow control) variables in MIDAS,
    Reply  11 Dec 2023, Stefan Ritt, Forum, the logic of handling history variables ? Screenshot_2023-12-12_at_09.03.13.pngScreenshot_2023-12-12_at_08.57.45.pngScreenshot_2023-12-12_at_08.55.14.pngScreenshot_2023-12-12_at_08.57.37.png
First of all it's important to understand that the slow control system has nothing to do
with events. So if you look at event statistics, these are the events with the slow control
data sent to the midas data file, not the history database. So the logging period (the one you 
       Reply  12 Dec 2023, Pavel Murat, Forum, the logic of handling history variables ? 
Hi Sfefan, thanks a lot for taking time to reproduce the issue! 

Here comes the resolution, and of course, it was something deeply trivial :  
          Reply  13 Dec 2023, Stefan Ritt, Forum, the logic of handling history variables ? 
> Also, I think that having a sine wave displayed by midas/examples/slowcont/scfe.cxx 
> would make this example even more helpful.
    Reply  28 Jan 2024, Konstantin Olchanski, Forum, the logic of handling history variables ? 
MIDAS history is very simple:

from your frontend, your write your history data to ODB /eq/xxx/variables (see below)
Entry  10 Jan 2024, Pavel Murat, Forum, slow control frontends - how much do they sleep and how often their drivers are called?  
Dear all,

I have implemented a number of slow control frontends which are directed to update the 
    Reply  11 Jan 2024, Stefan Ritt, Forum, slow control frontends - how much do they sleep and how often their drivers are called?  
Put a 

  ss_sleep(10);
       Reply  11 Jan 2024, Pavel Murat, Forum, slow control frontends - how much do they sleep and how often their drivers are called?  
Hi Stefan, thanks a lot !

I just thought that for the EQ_SLOW type equipment calls to sleep() could be hidden in mfe.cxx 
          Reply  12 Jan 2024, Stefan Ritt, Forum, slow control frontends - how much do they sleep and how often their drivers are called?  
> Hi Stefan, thanks a lot !

> I just thought that for the EQ_SLOW type equipment calls to sleep() could be hidden in mfe.cxx 
    Reply  28 Jan 2024, Konstantin Olchanski, Forum, slow control frontends - how much do they sleep and how often their drivers are called?  
> I have implemented a number of slow control frontends which are directed to update the 
> history once in every 10 sec, and they do just that. 
Entry  17 Jan 2024, Francesco Renga, Forum, History tags 
Dear experts,
         I would like to have some clarification about the meaning and use of the 
tags in the ODB under /History/Tags.
    Reply  18 Jan 2024, Stefan Ritt, Forum, History tags 
This part of the system has been designed by KO, so he should reply here.

Stefan
       Reply  28 Jan 2024, Konstantin Olchanski, Forum, History tags 
> This part of the system has been designed by KO, so he should reply here.

That's right. Some of this stuff is historical gibberish that is no longer needed 
Entry  17 Jan 2024, Andreas Suter, Bug Report, mhttpd eqtable midas-eqtable.png
Hi,

I like the new eqtable, but stumbled over some issues.
    Reply  17 Jan 2024, Stefan Ritt, Bug Report, mhttpd eqtable Screenshot_2024-01-17_at_14.09.30.png
> 1) In the attached snapshot you see that the values shown from our vacuum Pirani and Penning cells are all zero, which of course is not true.
> It would be nice to have under the equipment settings some formatting options, like the possibility to add units.
       Reply  17 Jan 2024, Andreas Suter, Bug Report, mhttpd eqtable 
Great! This is it.
Sorry that I missed it in the docu.
          Reply  18 Jan 2024, Andreas Suter, Forum, mhttpd eqtable hv-web.png
I have two more questions related to Units, Format for Equipment/Settings:

1) It looks as if I can have units per channel only for the Input/Output channels but not for Demand/Measured channels. 
             Reply  18 Jan 2024, Stefan Ritt, Forum, mhttpd eqtable 
I fixed both in the current version, so please give it a try.

Stefan
Entry  02 Jan 2024, Konstantin Olchanski, Forum, midas.triumf.ca alias moved to daq00.triumf.ca 
the DNS alias for midas.triumf.ca moved from old ladd00.triumf.ca to new 
daq00.triumf.ca. same as before it redirects to the MidasWiki and to the midas 
forum (elog) that moved from ladd00 to daq00 quite some time ago. if you see any 
    Reply  03 Jan 2024, Stefan Ritt, Forum, midas.triumf.ca alias moved to daq00.triumf.ca 
> the DNS alias for midas.triumf.ca moved from old ladd00.triumf.ca to new 
> daq00.triumf.ca. same as before it redirects to the MidasWiki and to the midas 
> forum (elog) that moved from ladd00 to daq00 quite some time ago. if you see any 
       Reply  03 Jan 2024, Konstantin Olchanski, Forum, midas.triumf.ca alias moved to daq00.triumf.ca 
> I found the first issue: The link to
> https://midas.triumf.ca/MidasWiki/index.php/Custom_plots_with_mplot
Entry  12 Dec 2023, Zaher Salman, Bug Report, Compilation error on RPi 
Hello,

Since commit bc227a8a34def271a598c0200ca30d73223c3373 I've been getting the compilation error below (on a Raspberry Pi 3 Model B Plus Rev
1.3).
    Reply  14 Dec 2023, Zaher Salman, Bug Report, Compilation error on RPi 
This issue was resolved thanks to Konstantin and Stefan. I simply had to update submodules:

git submodule update
       Reply  29 Dec 2023, Konstantin Olchanski, Bug Report, Compilation error on RPi 
> git pull
> git submodule update
          Reply  03 Jan 2024, Stefan Ritt, Bug Report, Compilation error on RPi 
> > git pull
> > git submodule update
Entry  27 Dec 2023, Konstantin Olchanski, Forum, MidasWiki updated to 1.39.6 
MidasWiki was updated to current mediawiki LTS 1.39.6 supported until Nov 2025, 
see https://www.mediawiki.org/wiki/Version_lifecycle
Entry  15 Dec 2023, Stefan Ritt, Info, Implementation of custom scatter, histogram and color map plots plots.png
Custom plots including scatter, histogram and color map plots have been 
implemented. This lets you plot graphs of X/Y data or histogram data stored in the 
ODB on a custom page. For some examples and documentation please go to
Entry  07 Dec 2023, Stefan Ritt, Info, Midas Holiday Update Screenshot_2023-12-08_at_08.19.48.png
Dear beloved MIDAS users,

I'm happy to announce a "holiday update" for MIDAS. In countless hours, Zaher from 
    Reply  10 Dec 2023, Andreas Suter, Info, Midas Holiday Update 
Hi Stefan and Zaher,

there is a problem with the new sequencer interface for midas.
       Reply  10 Dec 2023, Stefan Ritt, Info, Midas Holiday Update 
> If I understand the msequencer code correctly:
> Under '/Sequencer/State/Path' the path can be defined from where the msequencer gets the files, generates the xml, etc.
> However, the new javascript code reads/writes the files to '<exp>/userfiles/sequencer/'
          Reply  10 Dec 2023, Andreas Suter, Info, Midas Holiday Update 
> > If I understand the msequencer code correctly:
> > Under '/Sequencer/State/Path' the path can be defined from where the msequencer gets the files, generates the xml, etc.
> > However, the new javascript code reads/writes the files to '<exp>/userfiles/sequencer/'
             Reply  12 Dec 2023, Stefan Ritt, Info, Midas Holiday Update 
> > 3) Make /Sequencer/State/Path relative to <exp>/userfiles. Like if /Sequencer/State/Path=test would then result to a final directory <exp>/userfiles/sequencer/test
> > 
> > I'm kind of tempted to go with 3), since this allows the experiment to define different subdirectories under <exp>/userfiles/sequencer/... depending
Entry  09 Dec 2023, Pavel Murat, Forum, history plotting: where to convert the ADC readings into temps/voltages? 
to plot time dependencies of the monitored detector parameters, say, voltages or temperatures,
one needs to convert the coresponging ADC readings into floats.
    Reply  10 Dec 2023, Stefan Ritt, Forum, history plotting: where to convert the ADC readings into temps/voltages? 
> to plot time dependencies of the monitored detector parameters, say, voltages or temperatures,
> one needs to convert the coresponging ADC readings into floats.
Entry  09 Dec 2023, Pavel Murat, Forum, how to fix forgotten password ? 
[Dear All, I apologize in advance for spamming.]

1) I tried to login into the forum from the lab computer and realized 
Entry  22 Nov 2023, Pavel Murat, Forum, run number from an external (*SQL) db? 
Dear MIDAQ developers,

I wonder if there is a non-intrusive way to have an external (wrt MIDAS)*SQL database 
    Reply  22 Nov 2023, Ben Smith, Forum, run number from an external (*SQL) db? 
> I wonder if there is a non-intrusive way to have an external (wrt MIDAS)*SQL database 
> serving as a primary source of the run number information for a MIDAS-based DAQ system? 
> - like a plugin with a getNextRunNumber() function, for example, or a special client?
    Reply  22 Nov 2023, Stefan Ritt, Forum, run number from an external (*SQL) db? 
> - multiple subdetectors are taking test data during early commissioning 
> - a postgres db is a single sorce of run numbers.
> - test runs taken by different subsystems are assigned different [unique] run numbers and 
       Reply  01 Dec 2023, Pavel Murat, Forum, run number from an external (*SQL) db? 
> > - multiple subdetectors are taking test data during early commissioning 
> > - a postgres db is a single sorce of run numbers.
> > - test runs taken by different subsystems are assigned different [unique] run numbers and 
          Reply  02 Dec 2023, Stefan Ritt, Forum, run number from an external (*SQL) db? 
> Stefan, I don't think we're talking 'mis-use' - rather different subdetectors being commisisoned 
> at different locations, on an uncorrelated schedule, using independent run control (RC) instances. 
> At this point in time, we can't use a common RC instance. 
             Reply  02 Dec 2023, Pavel Murat, Forum, run number from an external (*SQL) db? 

> If you go in this direction, there is an alternative to what Ben wrote: Use the sequencer to start a run.
> The sequencer script can obtain a new run number from a central instance (e.g. by calling a shell script 
                Reply  03 Dec 2023, Pavel Murat, Forum, run number from an external (*SQL) db? 
> - how does one communicate with an external shell script from MSL ? 

trying to answer my own question, as I didn't find a clear answer in the forum archive :
                   Reply  04 Dec 2023, Stefan Ritt, Forum, run number from an external (*SQL) db? 
>    [that was not obvious from the documentation on MIDAS wiki, and adding a couple of clarifying 
>     sentences there would go long ways]
                Reply  04 Dec 2023, Stefan Ritt, Forum, run number from an external (*SQL) db? 
> - how does one communicate with an external shell script from MSL ? I looked at the MIDAS Sequencer page 
>   
>   https://daq00.triumf.ca/MidasWiki/index.php/Sequencer
Entry  01 Dec 2023, Pavel Murat, Forum, MIDAS state machine : how to get around w/o 'configured' state?  
I have one more question, though I understand that it could be somewhat border-line.

The MIDAS state machine doesn't seem to have a state in between 'initialized' and 
    Reply  02 Dec 2023, Stefan Ritt, Forum, MIDAS state machine : how to get around w/o 'configured' state?  muegamma.msl
> The MIDAS state machine doesn't seem to have a state in between 'initialized' and 
> 'running'.
> In a larger detectors with multiple subsystems, the DAQ systems often have one more state:
       Reply  02 Dec 2023, Pavel Murat, Forum, MIDAS state machine : how to get around w/o 'configured' state?  
> - To start a run, we start a special sequencer script. We have different scripts for
> calibration runs, data runs, special runs.
Entry  21 Nov 2023, Ivo Schulthess, Forum, Polled frontend writes data to ODB without RO_ODB 
Good morning, 

In our setup, we have a neutron detector that creates up to 16 MB of polled (EQ_POLLED) data in one event (event limit = 1) that we do not want to have
    Reply  22 Nov 2023, Stefan Ritt, Forum, Polled frontend writes data to ODB without RO_ODB 
I cannot confirm that. I just tried myself with examples/experiment/frontend.cxx, removed the RO_ODB, and the trigger events did NOT get copied to the ODB.

Actually you can debug the code yourself. The relevant line is in mfe.cxx:2075:
Entry  13 Nov 2023, Ivo Schulthess, Forum, mlogger does not HAVE_ROOT 
Good evening, 

I am setting up Midas (v2.1) for a new experiment. We want to save the data in the ROOT format. We installed ROOT from source (v6.28/06), and ROOTSYS is
    Reply  13 Nov 2023, Konstantin Olchanski, Forum, mlogger does not HAVE_ROOT 
> I am setting up Midas (v2.1) for a new experiment. We want to save the data in the ROOT format. We installed ROOT from source (v6.28/06), and ROOTSYS
is set. When we compile Midas, it says that it found ROOT. We set up a second logger channel where we set the filename to run%05d.root, the format to ROOT,
and the output to ROOT. Nevertheless, when starting a run, the logger writes the error that "channel '1' requested ROOT output, but mlogger is built without
    Reply  13 Nov 2023, Stefan Ritt, Forum, mlogger does not HAVE_ROOT 
When you do "cmake .." in the build directory, you will see

-- MIDAS: Found ROOT version xxx in yyy
       Reply  14 Nov 2023, Konstantin Olchanski, Forum, mlogger does not HAVE_ROOT 
> Finally, make sure you start "rmlogger" and not "mlogger". Only "rmlogger" contains the ROOT binding.

Stefan is right. I forgot this. As solution to our troubles, mlogger is built without root support. use rmlogger instead.
          Reply  14 Nov 2023, Ivo Schulthess, Forum, mlogger does not HAVE_ROOT 
> Stefan is right. I forgot this. As solution to our troubles, mlogger is built without root support. use rmlogger instead.

> K.O.
             Reply  14 Nov 2023, Stefan Ritt, Forum, mlogger does not HAVE_ROOT 
No, I'm not aware of this problem, but I suspect that your events somehow got corrupted. You can try the mdump utility
or the "Event Dump" web page to peek into your events, maybe you see an issue there. To give you more detailed information,
I would have to reproduce your problem, which is probably hard without your hardware.
                Reply  15 Nov 2023, Ivo Schulthess, Forum, mlogger does not HAVE_ROOT 
> No, I'm not aware of this problem, but I suspect that your events somehow got corrupted. You can try the mdump utility
> or the "Event Dump" web page to peek into your events, maybe you see an issue there. To give you more detailed information,
> I would have to reproduce your problem, which is probably hard without your hardware.
Entry  23 Oct 2023, Francesco Renga, Forum, Device with inputs and outputs 
Dear all,
       I'm writing a very simple device driver starting from the nulldev.cxx 
example. 
    Reply  24 Oct 2023, Stefan Ritt, Forum, Device with inputs and outputs 
The "multi" class driver takes care of that. It properly calls the SET and GET functions 
with the correct index. The code for that is in multi.cxx:105:
Entry  03 Oct 2023, Gennaro Tortone, Bug Report, Python midas.file_reader get_eor_odb_dump() 

Hi,
    Reply  16 Oct 2023, Ben Smith, Bug Report, Python midas.file_reader get_eor_odb_dump() 
Thanks for the bug report Gennaro! 

I've fixed the code so that we'll now find the end-of-run ODB dump even if the user is already at the end of the file when they call get_eor_odb_dump().
Entry  06 Oct 2023, Stefan Ritt, Info, New equipment display 
Since a long time we tried to convert all "static" mhttpd-generated pages to 
dynamic JavaScript. With the new history panel editor we were almost there. Now I 
committed the last missing piece - the equipment display. This is shown when you 
    Reply  09 Oct 2023, Stefan Ritt, Info, New equipment display Screenshot_2023-10-09_at_21.56.25.png
An additional functionality has been implemented on the equipment table:

You can now select several elements by Ctrl/Shift-Click on their names, then change the 
ELOG V3.1.4-2e1708b5