  551   13 Jan 2009 Stefan RittForummlogger problem> Sorry for being vague. I cleaned up the
ODB, but it doesn't seem to be the
> problem. Here is a sample run of mlogger
  
  554   14 Jan 2009 Konstantin OlchanskiForummlogger problem> The problem was already fixed some time
ago, so please update your version from the
SVN 
  
  560   26 Jan 2009 Derek EscontriasForumQuestion - ODB access from a custom pageHi, I am looking for a way to mutate ODB values
from a custom page. I have been
using the edit attribute for the 'odb' tag,
  
  561   27 Jan 2009 Suzannah DavielForumQuestion - ODB access from a custom pageAt present the only documentation on the Javascript
library is in this elog
e.g. Message 496 31 Jul 08
  
  563   04 Mar 2009 Dawei LiuForumAnalyzer gets killed cm_watchdog
Hello Midas experts:
  
  564   24 Mar 2009 Stefan RittForumAnalyzer gets killed cm_watchdogHi,

your log script sound to me like the analyzer
  
  565   17 Apr 2009 Jimmy NgaiForumMIDAS mhttpd custom page questionsDear All,

I have created a custom page (please see
 control_panel.html 
  566   20 Apr 2009 Jimmy NgaiForumMIDAS mhttpd custom page questionsDear All,

I have one more question. I use <odb src="odb
  
  567   06 May 2009 Stefan RittForumMIDAS mhttpd custom page questions> 1) I display the status of the run with
<odb src="/Runinfo/State">, but it 
> returns numbers which is not user friendly.
 control.html 
  568   06 May 2009 Stefan RittForumMIDAS mhttpd custom page questions> I have one more question. I use <odb src="odb
field" edit=1> to display an 
> editable ODB value, but how can I show
  
  594   15 Jun 2009 Jimmy NgaiForumTime limit of each runDear All,

Can one set a time limit for each run? I
  
  598   24 Jun 2009 Razvan Stefan GorneaForumFrontend and manual trigger questionHi,

I have a question related to the frontend
  
  600   25 Jun 2009 Stefan RittForumFrontend and manual trigger question> I would like to add manual trigger capability
and so I added the EQ_MANUAL_TRIG
> flag to the "CAEN" equipment type but the
  
  604   02 Jul 2009 Dawei LiuForumData taking hangs in the middle of runHi,

We are using midas to read ADC. It sometimes
  
  605   03 Jul 2009 Pierre-Andre AmaudruzForumData taking hangs in the middle of runHi Dawei,

Could you give more info on your setup:
  
  606   06 Jul 2009 Dawei LiuForumData taking hangs in the middle of runHi Pierr-Andre,

  
  607   08 Jul 2009 Konstantin OlchanskiForumjorway73a.c, Data taking hangs in the middle of run> > Could you give more info on your setup:
> > - CAMAC controller model
> Jorway 73A, we have three in hand and the
  
  608   18 Jul 2009 Exaos LeeForumjorway73a.c, Data taking hangs in the middle of run> > > Could you give more info on your setup:
> > > - CAMAC controller model
> > Jorway 73A, we have three in hand and
  
  609   03 Aug 2009 Exaos LeeForumHow to distinguish the status and value returned from "mvme_read_value(...)"The definition of mvme_read_value is as the
following:
[CODE]unsigned int EXPRT mvme_read_value(MVME_INTERFACE
  
  610   03 Aug 2009 Stefan RittForumHow to distinguish the status and value returned from "mvme_read_value(...)"[quote="Exaos Lee"]The definition of mvme_read_value
is as the following:
[CODE]unsigned int EXPRT mvme_read_value(MVME_INTERFACE
  