Back Midas Rome Roody Rootana
  Midas DAQ System, Page 5 of 136  Not logged in ELOG logo
New entries since:Wed Dec 31 16:00:00 1969
ID Date Author Topic Subject Text Attachments
  2655   12 Dec 2023 Zaher SalmanBug ReportCompilation error on RPiHello,

Since commit bc227a8a34def271a598c0200ca30d73223c3373
I've been getting the compilation error
  
  2654   12 Dec 2023 Stefan RittInfoMidas Holiday Update> > 3) Make /Sequencer/State/Path relative
to <exp>/userfiles. Like if /Sequencer/State/Path=test
would then result to a final directory <exp>/userfiles/sequencer/test
  
  2653   11 Dec 2023 Stefan RittForumthe logic of handling history variables ?First of all it's important to understand
that the slow control system has nothing
to do
 Screenshot_2023-12-12_at_09.03.13.pngScreenshot_2023-12-12_at_08.57.45.pngScreenshot_2023-12-12_at_08.55.14.pngScreenshot_2023-12-12_at_08.57.37.png 
  2652   11 Dec 2023 Pavel MuratForumthe logic of handling history variables ?Dear MIDAS developers,

I'm trying to understand handling of the
 11x 
  2651   10 Dec 2023 Andreas SuterInfoMidas Holiday Update> > If I understand the msequencer code correctly:
> > Under '/Sequencer/State/Path' the path
can be defined from where the msequencer
  
  2650   10 Dec 2023 Stefan RittForumhistory plotting: where to convert the ADC readings into temps/voltages?> to plot time dependencies of the monitored
detector parameters, say, voltages or temperatures,
> one needs to convert the coresponging ADC
  
  2649   10 Dec 2023 Stefan RittInfoMidas Holiday Update> If I understand the msequencer code correctly:
> Under '/Sequencer/State/Path' the path
can be defined from where the msequencer
  
  2648   10 Dec 2023 Andreas SuterInfoMidas Holiday UpdateHi Stefan and Zaher,

there is a problem with the new sequencer
  
  2647   09 Dec 2023 Pavel MuratForumhistory plotting: where to convert the ADC readings into temps/voltages?to plot time dependencies of the monitored
detector parameters, say, voltages or temperatures,
one needs to convert the coresponging ADC
  
  2646   09 Dec 2023 Pavel MuratForumhow to fix forgotten password ?[Dear All, I apologize in advance for spamming.]

1) I tried to login into the forum from the
  
  2645   07 Dec 2023 Stefan RittInfoMidas Holiday UpdateDear beloved MIDAS users,

I'm happy to announce a "holiday update"
 Screenshot_2023-12-08_at_08.19.48.png 
  2644   04 Dec 2023 Stefan RittForumrun number from an external (*SQL) db?>    [that was not obvious from the documentation
on MIDAS wiki, and adding a couple of clarifying
  
  2643   04 Dec 2023 Stefan RittForumrun number from an external (*SQL) db?> - how does one communicate with an external
shell script from MSL ? I looked at the MIDAS
Sequencer page 
  
  2642   03 Dec 2023 Pavel MuratForumrun number from an external (*SQL) db?> - how does one communicate with an external
shell script from MSL ? 
  
  2641   02 Dec 2023 Pavel MuratForumMIDAS state machine : how to get around w/o 'configured' state? > - To start a run, we start a special sequencer
script. We have different scripts for
> calibration runs, data runs, special runs.
  
  2640   02 Dec 2023 Pavel MuratForumrun number from an external (*SQL) db?
> If you go in this direction, there is an
alternative to what Ben wrote: Use the sequencer
  
  2639   02 Dec 2023 Stefan RittForumMIDAS state machine : how to get around w/o 'configured' state? > The MIDAS state machine doesn't seem to
have a state in between 'initialized' and
 muegamma.msl 
  2638   02 Dec 2023 Stefan RittForumrun number from an external (*SQL) db?> Stefan, I don't think we're talking 'mis-use'
- rather different subdetectors being commisisoned
  
  2637   01 Dec 2023 Pavel MuratForumMIDAS state machine : how to get around w/o 'configured' state? I have one more question, though I understand
that it could be somewhat border-line.
  
  2636   01 Dec 2023 Pavel MuratForumrun number from an external (*SQL) db?> > - multiple subdetectors are taking test
data during early commissioning 
> > - a postgres db is a single sorce of
  
ELOG V3.1.4-2e1708b5