> - multiple subdetectors are taking test data during early commissioning 
> - a postgres db is a single sorce of run numbers.
> - test runs taken by different subsystems are assigned different [unique] run numbers and 
    Reply  01 Dec 2023, Pavel Murat, Forum, run number from an external (*SQL) db? 
> > - multiple subdetectors are taking test data during early commissioning 
> > - a postgres db is a single sorce of run numbers.
> > - test runs taken by different subsystems are assigned different [unique] run numbers and 
Entry  01 Dec 2023, Pavel Murat, Forum, MIDAS state machine : how to get around w/o 'configured' state?  
I have one more question, though I understand that it could be somewhat border-line.

The MIDAS state machine doesn't seem to have a state in between 'initialized' and 
    Reply  02 Dec 2023, Stefan Ritt, Forum, run number from an external (*SQL) db? 
> Stefan, I don't think we're talking 'mis-use' - rather different subdetectors being commisisoned 
> at different locations, on an uncorrelated schedule, using independent run control (RC) instances. 
> At this point in time, we can't use a common RC instance. 
    Reply  02 Dec 2023, Stefan Ritt, Forum, MIDAS state machine : how to get around w/o 'configured' state?  muegamma.msl
> The MIDAS state machine doesn't seem to have a state in between 'initialized' and 
> 'running'.
> In a larger detectors with multiple subsystems, the DAQ systems often have one more state:
    Reply  02 Dec 2023, Pavel Murat, Forum, run number from an external (*SQL) db? 

> If you go in this direction, there is an alternative to what Ben wrote: Use the sequencer to start a run.
> The sequencer script can obtain a new run number from a central instance (e.g. by calling a shell script 
    Reply  02 Dec 2023, Pavel Murat, Forum, MIDAS state machine : how to get around w/o 'configured' state?  
> - To start a run, we start a special sequencer script. We have different scripts for
> calibration runs, data runs, special runs.
    Reply  03 Dec 2023, Pavel Murat, Forum, run number from an external (*SQL) db? 
> - how does one communicate with an external shell script from MSL ? 

trying to answer my own question, as I didn't find a clear answer in the forum archive :
    Reply  04 Dec 2023, Stefan Ritt, Forum, run number from an external (*SQL) db? 
> - how does one communicate with an external shell script from MSL ? I looked at the MIDAS Sequencer page 
>   
>   https://daq00.triumf.ca/MidasWiki/index.php/Sequencer
    Reply  04 Dec 2023, Stefan Ritt, Forum, run number from an external (*SQL) db? 
>    [that was not obvious from the documentation on MIDAS wiki, and adding a couple of clarifying 
>     sentences there would go long ways]
Entry  09 Dec 2023, Pavel Murat, Forum, how to fix forgotten password ? 
[Dear All, I apologize in advance for spamming.]

1) I tried to login into the forum from the lab computer and realized 
Entry  09 Dec 2023, Pavel Murat, Forum, history plotting: where to convert the ADC readings into temps/voltages? 
to plot time dependencies of the monitored detector parameters, say, voltages or temperatures,
one needs to convert the coresponging ADC readings into floats.
    Reply  10 Dec 2023, Stefan Ritt, Forum, history plotting: where to convert the ADC readings into temps/voltages? 
> to plot time dependencies of the monitored detector parameters, say, voltages or temperatures,
> one needs to convert the coresponging ADC readings into floats.
Entry  11 Dec 2023, Pavel Murat, Forum, the logic of handling history variables ? 11x
Dear MIDAS developers,

I'm trying to understand handling of the history (slow control) variables in MIDAS,
    Reply  11 Dec 2023, Stefan Ritt, Forum, the logic of handling history variables ? Screenshot_2023-12-12_at_09.03.13.pngScreenshot_2023-12-12_at_08.57.45.pngScreenshot_2023-12-12_at_08.55.14.pngScreenshot_2023-12-12_at_08.57.37.png
First of all it's important to understand that the slow control system has nothing to do
with events. So if you look at event statistics, these are the events with the slow control
data sent to the midas data file, not the history database. So the logging period (the one you 
    Reply  12 Dec 2023, Pavel Murat, Forum, the logic of handling history variables ? 
Hi Sfefan, thanks a lot for taking time to reproduce the issue! 

Here comes the resolution, and of course, it was something deeply trivial :  
    Reply  13 Dec 2023, Stefan Ritt, Forum, the logic of handling history variables ? 
> Also, I think that having a sine wave displayed by midas/examples/slowcont/scfe.cxx 
> would make this example even more helpful.
Entry  27 Dec 2023, Konstantin Olchanski, Forum, MidasWiki updated to 1.39.6 
MidasWiki was updated to current mediawiki LTS 1.39.6 supported until Nov 2025, 
see https://www.mediawiki.org/wiki/Version_lifecycle
Entry  02 Jan 2024, Konstantin Olchanski, Forum, midas.triumf.ca alias moved to daq00.triumf.ca 
the DNS alias for midas.triumf.ca moved from old ladd00.triumf.ca to new 
daq00.triumf.ca. same as before it redirects to the MidasWiki and to the midas 
forum (elog) that moved from ladd00 to daq00 quite some time ago. if you see any 
    Reply  03 Jan 2024, Stefan Ritt, Forum, midas.triumf.ca alias moved to daq00.triumf.ca 
> the DNS alias for midas.triumf.ca moved from old ladd00.triumf.ca to new 
> daq00.triumf.ca. same as before it redirects to the MidasWiki and to the midas 
> forum (elog) that moved from ladd00 to daq00 quite some time ago. if you see any 