14 Nov 2023, Stefan Ritt, Forum, mlogger does not HAVE_ROOT
|
No, I'm not aware of this problem, but I suspect that your events somehow got corrupted. You can try the mdump utility
or the "Event Dump" web page to peek into your events, maybe you see an issue there. To give you more detailed information,
I would have to reproduce your problem, which is probably hard without your hardware.
|
15 Nov 2023, Ivo Schulthess, Forum, mlogger does not HAVE_ROOT
|
> No, I'm not aware of this problem, but I suspect that your events somehow got corrupted. You can try the mdump utility
> or the "Event Dump" web page to peek into your events, maybe you see an issue there. To give you more detailed information,
> I would have to reproduce your problem, which is probably hard without your hardware.
|
21 Nov 2023, Ivo Schulthess, Forum, Polled frontend writes data to ODB without RO_ODB
|
Good morning,
In our setup, we have a neutron detector that creates up to 16 MB of polled (EQ_POLLED) data in one event (event limit = 1) that we do not want to have |
22 Nov 2023, Stefan Ritt, Forum, Polled frontend writes data to ODB without RO_ODB
|
I cannot confirm that. I just tried myself with examples/experiment/frontend.cxx, removed the RO_ODB, and the trigger events did NOT get copied to the ODB.
Actually you can debug the code yourself. The relevant line is in mfe.cxx:2075:
|
22 Nov 2023, Pavel Murat, Forum, run number from an external (*SQL) db?
|
Dear MIDAQ developers,
I wonder if there is a non-intrusive way to have an external (wrt MIDAS)*SQL database
|
22 Nov 2023, Ben Smith, Forum, run number from an external (*SQL) db?
|
> I wonder if there is a non-intrusive way to have an external (wrt MIDAS)*SQL database
> serving as a primary source of the run number information for a MIDAS-based DAQ system?
> - like a plugin with a getNextRunNumber() function, for example, or a special client?
|
22 Nov 2023, Stefan Ritt, Forum, run number from an external (*SQL) db?
|
> - multiple subdetectors are taking test data during early commissioning
> - a postgres db is a single sorce of run numbers.
> - test runs taken by different subsystems are assigned different [unique] run numbers and
|
01 Dec 2023, Pavel Murat, Forum, run number from an external (*SQL) db?
|
> > - multiple subdetectors are taking test data during early commissioning
> > - a postgres db is a single sorce of run numbers.
> > - test runs taken by different subsystems are assigned different [unique] run numbers and
|
01 Dec 2023, Pavel Murat, Forum, MIDAS state machine : how to get around w/o 'configured' state?
|
I have one more question, though I understand that it could be somewhat border-line.
The MIDAS state machine doesn't seem to have a state in between 'initialized' and
|
02 Dec 2023, Stefan Ritt, Forum, run number from an external (*SQL) db?
|
> Stefan, I don't think we're talking 'mis-use' - rather different subdetectors being commisisoned
> at different locations, on an uncorrelated schedule, using independent run control (RC) instances.
> At this point in time, we can't use a common RC instance.
|
02 Dec 2023, Stefan Ritt, Forum, MIDAS state machine : how to get around w/o 'configured' state?
|
> The MIDAS state machine doesn't seem to have a state in between 'initialized' and
> 'running'.
> In a larger detectors with multiple subsystems, the DAQ systems often have one more state:
|
02 Dec 2023, Pavel Murat, Forum, run number from an external (*SQL) db?
|
>
> If you go in this direction, there is an alternative to what Ben wrote: Use the sequencer to start a run.
> The sequencer script can obtain a new run number from a central instance (e.g. by calling a shell script
|
02 Dec 2023, Pavel Murat, Forum, MIDAS state machine : how to get around w/o 'configured' state?
|
> - To start a run, we start a special sequencer script. We have different scripts for
> calibration runs, data runs, special runs.
>
|
03 Dec 2023, Pavel Murat, Forum, run number from an external (*SQL) db?
|
> - how does one communicate with an external shell script from MSL ?
trying to answer my own question, as I didn't find a clear answer in the forum archive :
|
04 Dec 2023, Stefan Ritt, Forum, run number from an external (*SQL) db?
|
> - how does one communicate with an external shell script from MSL ? I looked at the MIDAS Sequencer page
>
> https://daq00.triumf.ca/MidasWiki/index.php/Sequencer
|
04 Dec 2023, Stefan Ritt, Forum, run number from an external (*SQL) db?
|
> [that was not obvious from the documentation on MIDAS wiki, and adding a couple of clarifying
> sentences there would go long ways]
|
09 Dec 2023, Pavel Murat, Forum, how to fix forgotten password ?
|
[Dear All, I apologize in advance for spamming.]
1) I tried to login into the forum from the lab computer and realized
|
09 Dec 2023, Pavel Murat, Forum, history plotting: where to convert the ADC readings into temps/voltages?
|
to plot time dependencies of the monitored detector parameters, say, voltages or temperatures,
one needs to convert the coresponging ADC readings into floats.
|
10 Dec 2023, Stefan Ritt, Forum, history plotting: where to convert the ADC readings into temps/voltages?
|
> to plot time dependencies of the monitored detector parameters, say, voltages or temperatures,
> one needs to convert the coresponging ADC readings into floats.
>
|
11 Dec 2023, Pavel Murat, Forum, the logic of handling history variables ? 11x
|
Dear MIDAS developers,
I'm trying to understand handling of the history (slow control) variables in MIDAS,
|