mpmt-daq02:/dev/sda 1671801901 smartctl 7.1 2019-12-30 r5022 [x86_64-linux-5.15.0-53-generic] (local build) Copyright (C) 2002-19, Bruce Allen, Christian Franke, www.smartmontools.org === START OF INFORMATION SECTION === Device Model: KINGSTON SKC600256G Serial Number: 50026B7782F29AFE LU WWN Device Id: 5 0026b7 782f29afe Firmware Version: S4500103 User Capacity: 256,060,514,304 bytes [256 GB] Sector Sizes: 512 bytes logical, 4096 bytes physical Rotation Rate: Solid State Device Form Factor: 2.5 inches Device is: Not in smartctl database [for details use: -P showall] ATA Version is: ACS-3 T13/2161-D revision 5 SATA Version is: SATA 3.3, 6.0 Gb/s (current: 6.0 Gb/s) Local Time is: Fri Dec 23 05:25:01 2022 PST SMART support is: Available - device has SMART capability. SMART support is: Enabled === START OF READ SMART DATA SECTION === SMART overall-health self-assessment test result: PASSED General SMART Values: Offline data collection status: (0x80) Offline data collection activity was never started. Auto Offline Data Collection: Enabled. Self-test execution status: ( 0) The previous self-test routine completed without error or no self-test has ever been run. Total time to complete Offline data collection: ( 0) seconds. Offline data collection capabilities: (0x7b) SMART execute Offline immediate. Auto Offline data collection on/off support. Suspend Offline collection upon new command. Offline surface scan supported. Self-test supported. Conveyance Self-test supported. Selective Self-test supported. SMART capabilities: (0x0002) Does not save SMART data before entering power-saving mode. Supports SMART auto save timer. Error logging capability: (0x01) Error logging supported. General Purpose Logging supported. Short self-test routine recommended polling time: ( 2) minutes. Extended self-test routine recommended polling time: ( 30) minutes. Conveyance self-test routine recommended polling time: ( 2) minutes. SCT capabilities: (0x0031) SCT Status supported. SCT Feature Control supported. SCT Data Table supported. SMART Attributes Data Structure revision number: 16 Vendor Specific SMART Attributes with Thresholds: ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE 1 Raw_Read_Error_Rate 0x0000 100 100 000 Old_age Offline - 0 5 Reallocated_Sector_Ct 0x0000 100 100 000 Old_age Offline - 0 9 Power_On_Hours 0x0000 100 100 000 Old_age Offline - 514 12 Power_Cycle_Count 0x0000 100 100 000 Old_age Offline - 26 148 Unknown_Attribute 0x0000 100 100 000 Old_age Offline - 85 149 Unknown_Attribute 0x0000 100 100 000 Old_age Offline - 16 150 Unknown_Attribute 0x0000 100 100 000 Old_age Offline - 0 151 Unknown_Attribute 0x0000 100 100 000 Old_age Offline - 9 159 Unknown_Attribute 0x0000 100 100 000 Old_age Offline - 0 160 Unknown_Attribute 0x0000 100 100 000 Old_age Offline - 0 161 Unknown_Attribute 0x0000 100 100 000 Old_age Offline - 15 163 Unknown_Attribute 0x0000 100 100 000 Old_age Offline - 6 164 Unknown_Attribute 0x0000 100 100 000 Old_age Offline - 1381 165 Unknown_Attribute 0x0000 100 100 000 Old_age Offline - 9 166 Unknown_Attribute 0x0000 100 100 000 Old_age Offline - 2 167 Unknown_Attribute 0x0000 100 100 000 Old_age Offline - 6 168 Unknown_Attribute 0x0000 100 100 000 Old_age Offline - 2000 169 Unknown_Attribute 0x0000 100 100 000 Old_age Offline - 100 177 Wear_Leveling_Count 0x0000 100 100 050 Old_age Offline - 0 181 Program_Fail_Cnt_Total 0x0000 100 100 000 Old_age Offline - 0 182 Erase_Fail_Count_Total 0x0000 100 100 000 Old_age Offline - 0 192 Power-Off_Retract_Count 0x0000 100 100 000 Old_age Offline - 5 194 Temperature_Celsius 0x0000 100 100 000 Old_age Offline - 26 195 Hardware_ECC_Recovered 0x0000 100 100 000 Old_age Offline - 0 196 Reallocated_Event_Count 0x0000 100 100 016 Old_age Offline - 0 199 UDMA_CRC_Error_Count 0x0000 100 100 050 Old_age Offline - 0 232 Available_Reservd_Space 0x0000 100 100 000 Old_age Offline - 100 241 Total_LBAs_Written 0x0000 100 100 000 Old_age Offline - 7177 242 Total_LBAs_Read 0x0000 100 100 000 Old_age Offline - 965 245 Unknown_Attribute 0x0000 100 100 000 Old_age Offline - 55930 SMART Error Log Version: 1 No Errors Logged SMART Self-test log structure revision number 1 No self-tests have been logged. [To run self-tests, use: smartctl -t] SMART Selective self-test log data structure revision number 1 SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS 1 0 0 Not_testing 2 0 0 Not_testing 3 0 0 Not_testing 4 0 0 Not_testing 5 0 0 Completed [00% left] (0-65535) Selective self-test flags (0x0): After scanning selected spans, do NOT read-scan remainder of disk. If Selective self-test is pending on power-up, resume after 0 minute delay.