dsvslice:/dev/sdb 1715084701 smartctl 6.6 2016-05-31 r4324 [x86_64-linux-5.4.0-150-generic] (local build) Copyright (C) 2002-16, Bruce Allen, Christian Franke, www.smartmontools.org === START OF INFORMATION SECTION === Device Model: SAMSUNG MZ7KH480HAHQ-00005 Serial Number: S47MNE0M400586 LU WWN Device Id: 5 002538 e0011bf47 Firmware Version: HXM7304Q User Capacity: 480,103,981,056 bytes [480 GB] Sector Sizes: 512 bytes logical, 4096 bytes physical Rotation Rate: Solid State Device Form Factor: 2.5 inches Device is: Not in smartctl database [for details use: -P showall] ATA Version is: Unknown(0x0ffc), ACS-4 T13/BSR INCITS 529 revision 5 SATA Version is: SATA 3.2, 6.0 Gb/s (current: 6.0 Gb/s) Local Time is: Tue May 7 05:25:01 2024 PDT SMART support is: Available - device has SMART capability. SMART support is: Enabled === START OF READ SMART DATA SECTION === SMART overall-health self-assessment test result: PASSED General SMART Values: Offline data collection status: (0x00) Offline data collection activity was never started. Auto Offline Data Collection: Disabled. Self-test execution status: ( 0) The previous self-test routine completed without error or no self-test has ever been run. Total time to complete Offline data collection: ( 0) seconds. Offline data collection capabilities: (0x53) SMART execute Offline immediate. Auto Offline data collection on/off support. Suspend Offline collection upon new command. No Offline surface scan supported. Self-test supported. No Conveyance Self-test supported. Selective Self-test supported. SMART capabilities: (0x0003) Saves SMART data before entering power-saving mode. Supports SMART auto save timer. Error logging capability: (0x01) Error logging supported. General Purpose Logging supported. Short self-test routine recommended polling time: ( 2) minutes. Extended self-test routine recommended polling time: ( 35) minutes. SCT capabilities: (0x003d) SCT Status supported. SCT Error Recovery Control supported. SCT Feature Control supported. SCT Data Table supported. SMART Attributes Data Structure revision number: 1 Vendor Specific SMART Attributes with Thresholds: ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE 5 Reallocated_Sector_Ct 0x0033 100 100 010 Pre-fail Always - 0 9 Power_On_Hours 0x0032 092 092 000 Old_age Always - 37387 12 Power_Cycle_Count 0x0032 099 099 000 Old_age Always - 22 177 Wear_Leveling_Count 0x0013 099 099 005 Pre-fail Always - 272 179 Used_Rsvd_Blk_Cnt_Tot 0x0013 100 100 010 Pre-fail Always - 0 180 Unused_Rsvd_Blk_Cnt_Tot 0x0013 100 100 010 Pre-fail Always - 2117 181 Program_Fail_Cnt_Total 0x0032 100 100 010 Old_age Always - 0 182 Erase_Fail_Count_Total 0x0032 100 100 010 Old_age Always - 0 183 Runtime_Bad_Block 0x0013 100 100 010 Pre-fail Always - 0 184 End-to-End_Error 0x0033 100 100 097 Pre-fail Always - 0 187 Reported_Uncorrect 0x0032 100 100 000 Old_age Always - 0 190 Airflow_Temperature_Cel 0x0032 073 047 000 Old_age Always - 27 194 Temperature_Celsius 0x0022 073 047 000 Old_age Always - 27 (Min/Max 15/53) 195 Hardware_ECC_Recovered 0x001a 200 200 000 Old_age Always - 0 197 Current_Pending_Sector 0x0032 100 100 000 Old_age Always - 0 199 UDMA_CRC_Error_Count 0x003e 100 100 000 Old_age Always - 0 202 Unknown_SSD_Attribute 0x0033 100 100 010 Pre-fail Always - 0 235 Unknown_Attribute 0x0012 099 099 000 Old_age Always - 17 241 Total_LBAs_Written 0x0032 099 099 000 Old_age Always - 92928440639 242 Total_LBAs_Read 0x0032 099 099 000 Old_age Always - 33407788557 243 Unknown_Attribute 0x0032 100 100 000 Old_age Always - 0 244 Unknown_Attribute 0x0032 100 100 000 Old_age Always - 0 245 Unknown_Attribute 0x0032 100 100 000 Old_age Always - 65535 246 Unknown_Attribute 0x0032 100 100 000 Old_age Always - 65535 247 Unknown_Attribute 0x0032 100 100 000 Old_age Always - 65535 251 Unknown_Attribute 0x0032 100 100 000 Old_age Always - 269330271744 SMART Error Log Version: 1 No Errors Logged SMART Self-test log structure revision number 1 No self-tests have been logged. [To run self-tests, use: smartctl -t] SMART Selective self-test log data structure revision number 1 SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS 1 0 0 Not_testing 2 0 0 Not_testing 3 0 0 Not_testing 4 0 0 Not_testing 5 0 0 Not_testing Selective self-test flags (0x0): After scanning selected spans, do NOT read-scan remainder of disk. If Selective self-test is pending on power-up, resume after 0 minute delay.