isdaq01:/dev/sda 1711455901 smartctl 7.2 2020-12-30 r5155 [x86_64-linux-6.5.0-15-generic] (local build) Copyright (C) 2002-20, Bruce Allen, Christian Franke, www.smartmontools.org === START OF INFORMATION SECTION === Device Model: WD Blue SA510 2.5 250GB Serial Number: 22243Z807500 LU WWN Device Id: 5 001b44 8b0c04b15 Firmware Version: 52008100 User Capacity: 250,059,350,016 bytes [250 GB] Sector Size: 512 bytes logical/physical Rotation Rate: Solid State Device Form Factor: 2.5 inches TRIM Command: Available, deterministic Device is: Not in smartctl database [for details use: -P showall] ATA Version is: ACS-4, ACS-2 T13/2015-D revision 3 SATA Version is: SATA 3.2, 6.0 Gb/s (current: 1.5 Gb/s) Local Time is: Tue Mar 26 05:25:02 2024 PDT SMART support is: Available - device has SMART capability. SMART support is: Enabled === START OF READ SMART DATA SECTION === SMART overall-health self-assessment test result: PASSED General SMART Values: Offline data collection status: (0x00) Offline data collection activity was never started. Auto Offline Data Collection: Disabled. Self-test execution status: ( 0) The previous self-test routine completed without error or no self-test has ever been run. Total time to complete Offline data collection: ( 0) seconds. Offline data collection capabilities: (0x71) SMART execute Offline immediate. No Auto Offline data collection support. Suspend Offline collection upon new command. No Offline surface scan supported. Self-test supported. Conveyance Self-test supported. Selective Self-test supported. SMART capabilities: (0x0003) Saves SMART data before entering power-saving mode. Supports SMART auto save timer. Error logging capability: (0x01) Error logging supported. General Purpose Logging supported. Short self-test routine recommended polling time: ( 1) minutes. Extended self-test routine recommended polling time: ( 10) minutes. Conveyance self-test routine recommended polling time: ( 1) minutes. SMART Attributes Data Structure revision number: 0 Vendor Specific SMART Attributes with Thresholds: ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE 5 Reallocated_Sector_Ct 0x0032 100 100 010 Old_age Always - 0 9 Power_On_Hours 0x0032 100 100 000 Old_age Always - 0 12 Power_Cycle_Count 0x0032 100 100 000 Old_age Always - 1202 165 Unknown_Attribute 0x0032 100 100 000 Old_age Always - 12889948232 166 Unknown_Attribute 0x0032 100 100 000 Old_age Always - 1 167 Unknown_Attribute 0x0032 100 100 000 Old_age Always - 113 168 Unknown_Attribute 0x0032 100 100 000 Old_age Always - 2 169 Unknown_Attribute 0x0032 100 100 000 Old_age Always - 188 170 Unknown_Attribute 0x0032 100 100 000 Old_age Always - 0 171 Unknown_Attribute 0x0032 100 100 000 Old_age Always - 0 172 Unknown_Attribute 0x0032 100 100 000 Old_age Always - 0 173 Unknown_Attribute 0x0032 100 100 005 Old_age Always - 1 174 Unknown_Attribute 0x0032 100 100 000 Old_age Always - 1192 184 End-to-End_Error 0x0032 100 100 097 Old_age Always - 0 187 Reported_Uncorrect 0x0032 100 100 000 Old_age Always - 0 188 Command_Timeout 0x0032 100 100 000 Old_age Always - 0 194 Temperature_Celsius 0x0022 100 100 014 Old_age Always - 28 (Min/Max 21/36) 199 UDMA_CRC_Error_Count 0x0032 100 100 000 Old_age Always - 0 230 Unknown_SSD_Attribute 0x0032 100 100 000 Old_age Always - 77310722066 232 Available_Reservd_Space 0x0033 100 100 004 Pre-fail Always - 47 233 Media_Wearout_Indicator 0x0032 100 100 000 Old_age Always - 10 234 Unknown_Attribute 0x0032 100 100 000 Old_age Always - 546 241 Total_LBAs_Written 0x0030 253 253 000 Old_age Offline - 233 242 Total_LBAs_Read 0x0030 253 253 000 Old_age Offline - 32 244 Unknown_Attribute 0x0032 100 100 000 Old_age Always - 0 Warning! SMART ATA Error Log Structure error: invalid SMART checksum. SMART Error Log Version: 1 No Errors Logged SMART Self-test log structure revision number 1 No self-tests have been logged. [To run self-tests, use: smartctl -t] SMART Selective self-test log data structure revision number 1 SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS 1 0 0 Not_testing 2 0 0 Not_testing 3 0 0 Not_testing 4 0 0 Not_testing 5 0 0 Not_testing Selective self-test flags (0x0): After scanning selected spans, do NOT read-scan remainder of disk. If Selective self-test is pending on power-up, resume after 0 minute delay.