2018-03-19 00:00:00 Issue tagged as "SCA D Dead"
2018-03-19 00:00:00 Found several metallic flakes on SCA D pins and near SCA C. Have cleaned the board. Metal flakes possibly caused from solder splattering.
2018-05-07 00:00:00 Still has 1.9V SCA VREF. SCA VREF2 measures 0.5V instead of 1.9V
2018-05-07 00:00:00 Still has 1.9V SCA VREF. SCAD VREF2 measures 0.5V instead of 1.9V
2018-06-04 00:00:00 Wrong VREF resistor on SCAD replaced
2018-06-04 00:00:00 SCA C clock does not make it through the ribbon cable. Likely PCB manufacture issue.
2019-09-18 00:00:00 no boot from user page. K.O.
2019-09-19 00:00:00 +5V current is high: should be 2.7A, see interrmittent around 5-6A. K.O.
2019-09-23 00:00:00 high +5V current fixed by putting capton isolator under the PWB. K.O.
2019-09-23 00:00:00 sca0 ok, sca1, sca2 dead, sca3 reads noise instead of field wire pulser waveform. K.O.
2020-10-04 00:00:00 voltages ok, boots current firmware. K.O.
2020-10-04 00:00:00 attempt to write to user epcq page fails with a data miscompare (read after write). K.O.
2020-10-09 00:00:00 clocks: SCA-A W=ok, R=largeamp, SCA-B W="1 pulse instead of pulse train", R=0V, SCA-C W=0V, R=0V, SCA-D W=0V, R=ok. K.O.