Search results

Jump to navigation Jump to search
  • ...Fastbus, CAMAC, RS232, GPIB, USB, ethernet, fiber optic and MSCB attached data acquisition devices. MIDAS is written in C/C++ and runs on Linux, MacOS and * [https://bitbucket.org/tmidas/manalyzer/src/master/ manalyzer] - data analysis from TRIUMF
    2 KB (292 words) - 17:58, 13 September 2023
  • ** What Midas can do for you: ... collect data from different source (HW, Network) 3 Data logging : Data collection scheme
    3 KB (301 words) - 22:42, 22 July 2013
  • ...the ROOT (https://root.cern.ch) based data analysis package for the MIDAS Data Acquisition system (https://midas.triumf.ca). ...d for decoding the XML dump of MIDAS ODB typically embedded in every MIDAS data file. (libMidasInterface)
    4 KB (643 words) - 13:26, 4 March 2016
  • ...is a variable length event format. It uses [[MIDAS Event Structure #MIDAS Data Bank |banks]] as subsets of an event. ...banks during the analysis process to the event in process. After the first analysis stage, the event can contain in addition to the the raw ADC bank, a bank wi
    2 KB (393 words) - 11:46, 6 April 2020
  • ...is#Analyzer | Analyzer]]''' → ''Data consumer for Online/Offline data analyzer'' * '''[[Data Logger]]''' → ''Data Consumer for data recording''
    2 KB (245 words) - 18:09, 11 December 2019
  • ...a from the hardware and transmit this information to a central place where data logging and analysis can be performed.
    2 KB (230 words) - 10:26, 5 January 2024
  • ...o local/remote computer, data logging capability, data analysis framework, data monitoring, full run control, and web interface for experiment control/moni ...on system such as a central database editor (odbedit), webserver (mhttpd), data logger (mlogger) etc. This section describes each individual task and link
    4 KB (617 words) - 12:30, 4 August 2023
  • :* where the data is to be stored (e.g. tape), ...,and analyzing the data during or after the run is described under [[Data Analysis]].
    3 KB (436 words) - 16:55, 15 February 2014
  • "MIDAS" is an acronym for Maximum Integrated Data Acquisition System. MIDAS is a general-purpose system for event-based data acquisition in small and medium scale Physics experiments. It is an on-goin
    5 KB (728 words) - 15:13, 4 August 2023
  • ...time" hardware source (the default) or from a data save-set. Note that for analysis replay using "analyzer", this flag will be switched off. the saved data file already exists, or on alarm (see [[/Experiment ODB tree#Prevent start
    6 KB (774 words) - 13:17, 25 November 2016
  • === <span style="color: purple;">''Data dir''</span> === Once mlogger is running , the key <span style="color: purple;">''Data dir''</span> will be pointing to the location of
    14 KB (2,191 words) - 05:48, 11 November 2022
  • *The Buffer Manager - ''Handles the experimental data transfer from the frontend to the backend'' - ...gger Data storage - ''Midas client handling the recording of the collected data to physical storage media'' -
    18 KB (2,954 words) - 18:11, 4 January 2016
  • ...e than just checking the event numbers; we need to process the data in the data banks. The rootana analyzer classes facilitate this by providing decoding c ...be quite different. You should see the individual decoders to see how the data is organized; for now we currently have the following decoders (mostly for
    9 KB (1,351 words) - 09:12, 19 April 2017
  • ...subtree|Settings subtree]] is set to "y", this logging channel is active. Data are only logged from channels that are active. Set to "n" to disable data logging from this channel.
    23 KB (3,373 words) - 16:09, 22 May 2019
  • ...ed for examples/hbookexpt/Makefile for building the MIDAS analyzer - event analysis against HBOOK and PAW. The path to the cernlib is requested and expected to ...ump|mdump]] can be built with zlib.a in order to gain direct access to the data within a file with extension mid.gz. By default this option is disabled exc
    8 KB (1,230 words) - 17:56, 10 July 2015
  • Further analysis: interrupt (quick), a page fault (when we may have to wait until data is read from the swap file)
    14 KB (2,456 words) - 09:53, 6 August 2013
  • ...MIDAS web interface. These custom pages usually display ODB parameters or data to the user. They can contain specific links to the ODB so the user may als ...tons are overlaid on the graphics using CSS with absolute positioning. The analysis ratio on the top right is also done with JavaScript accessing the required
    39 KB (5,727 words) - 18:22, 25 March 2024
  • ...ill be built later in this Quickstart). It is also possible to write midas data directly to ROOT files if desired. rootana is an optional framework for analyzing midas data in realtime and displaying plots (either by a graphical interface or via we
    38 KB (5,821 words) - 03:18, 3 January 2024
  • * Lazylogger now supports writing data over SFTP. ...as well as <code>onchange()</code>. Most elements now also support a <code>data-validate</code> callback.
    15 KB (2,325 words) - 05:31, 29 September 2021