ReadOn Flags: Difference between revisions

From MidasWiki
Jump to navigation Jump to search
No edit summary
(The midas documentation has moved to https://midas.triumf.ca/docs/)
 
(2 intermediate revisions by one other user not shown)
Line 1: Line 1:
Read-on flags RO_xxx are used in the [[Equipment List Parameters#ReadOn|Read On]]  field of the equipment declaration to specify when the read-out of an event occurs.
The midas documentation has moved. See [https://midas.triumf.ca/docs/develop/features/acquiring_data/frontends/programming/#when-to-read-data When to read data] in Frontends: programming for the new documentation about the "read on" flags.
 
;RO_RUNNING : While running
;RO_STOPPED : Before stopping run
;RO_PAUSED : When run is paused
;RO_BOR : At the beginning of run
;RO_EOR : At the end of run
;RO_PAUSE : Before pausing the run
;RO_RESUME : Before resuming the run
;RO_TRANSITIONS : At all transitions
;RO_ALWAYS :Always (independent of the run status)
;RO_ODB :Copies the event to the <span style="color: purple; font-style:italic;">/Equipment/<equipment name>/Variables</span> ODB tree. The ODB is updated with a new event approximately every second. Note that this feature is generally used only for testing or monitoring, as writing large amounts of data to the ODB takes time.

Latest revision as of 22:01, 30 October 2026

The midas documentation has moved. See When to read data in Frontends: programming for the new documentation about the "read on" flags.