ReadOn Flags: Difference between revisions

From MidasWiki
Jump to navigation Jump to search
(Created page with "Read-on flags RO_xxx are used in the Read On field of the equipment declaration to specify when the read-out of an event occurs. ;RO_RU...")
 
No edit summary
Line 10: Line 10:
;RO_TRANSITIONS : At all transitions
;RO_TRANSITIONS : At all transitions
;RO_ALWAYS :Always (independent of the run status)
;RO_ALWAYS :Always (independent of the run status)
;RO_ODB :Copies the event to the /Equipment/<equipment name>/Variables ODB tree. The ODB is updated with a new event approximately every second. Note that this feature is generally used only for testing or monitoring, as writing large amounts of data to the ODB takes time.
;RO_ODB :Copies the event to the <span style="color: purple; font-style:italic;">/Equipment/<equipment name>/Variables</span> ODB tree. The ODB is updated with a new event approximately every second. Note that this feature is generally used only for testing or monitoring, as writing large amounts of data to the ODB takes time.

Revision as of 13:38, 30 October 2013

Read-on flags RO_xxx are used in the Read On field of the equipment declaration to specify when the read-out of an event occurs.

RO_RUNNING
While running
RO_STOPPED
Before stopping run
RO_PAUSED
When run is paused
RO_BOR
At the beginning of run
RO_EOR
At the end of run
RO_PAUSE
Before pausing the run
RO_RESUME
Before resuming the run
RO_TRANSITIONS
At all transitions
RO_ALWAYS
Always (independent of the run status)
RO_ODB
Copies the event to the /Equipment/<equipment name>/Variables ODB tree. The ODB is updated with a new event approximately every second. Note that this feature is generally used only for testing or monitoring, as writing large amounts of data to the ODB takes time.