Mhttpd: Difference between revisions
No edit summary |
No edit summary |
||
Line 1: | Line 1: | ||
== Purpose | <div style="column-count:4;-moz-column-count:4;-webkit-column-count:4"> | ||
* [[Midas_documentation|Midas Documentation]] | |||
* [[Feature_listing|Feature Listing]] | |||
* [[Application_listing|Application Listing]] | |||
* [[Online_Database|Online Database]] | |||
</div> | |||
= Links = | |||
<div style="column-count:3;-moz-column-count:3;-webkit-column-count:3"> | |||
* [[odbedit]] | |||
* [[MIDAS Experiment Name]] | |||
* [[MIDAS Host Name]] | |||
</div> | |||
= Purpose = | |||
The <span style="color:darkcyan;">''mhttpd''</span> utility runs the MIDAS Web Server which allows the user to communicate with an experiment using any web browser. It is used primarily for run control. | The <span style="color:darkcyan;">''mhttpd''</span> utility runs the MIDAS Web Server which allows the user to communicate with an experiment using any web browser. It is used primarily for run control. | ||
= Arguments = | |||
-p port | -p port : port number e.g. 8081 (no default) | ||
[-h] | [-h hostname ] : see [[Common Parameters to MIDAS Utilities]] | ||
[-e] | [-e experiment] : see [[Common Parameters to MIDAS Utilities]] | ||
[-v] | [-v] : display verbose HTTP communication | ||
[-D] | [-D] : starts program as a daemon | ||
[-E] | [-E] : only display ELog system | ||
[-H] | [-H] : only display history plots | ||
[-a] | [-a hostname] : only allow access for specific host(s). Several [-a Hostname] statements might be given | ||
[-help] | [-help] : display usage information | ||
= Usage = | |||
The TCP/IP port number is '''required''' as an argument in order to listen to the web-based request. | The TCP/IP port number is '''required''' as an argument in order to listen to the web-based request. | ||
<br>e.g. if mhttpd is started on host machine "myhost" on port 8081 as follows | <br>e.g. if mhttpd is started on IP host machine "myhost" on port 8081 as follows | ||
mhttpd -p 8081 -D | mhttpd -p 8081 -D | ||
access to the [[#Features|''Midas status page'']] can be obtained by pointing a web browser to | access to the [[#Features|''Midas status page'']] can be obtained by pointing a web browser to | ||
http://myhost.mydomain | http://myhost.mydomain:8081 | ||
;Note | ;Note | ||
Line 30: | Line 43: | ||
= Features = | |||
<span style="color:darkcyan;">''mhttpd''</span> provides a means for run control including monitoring of the run parameters. | <span style="color:darkcyan;">''mhttpd''</span> provides a means for run control including monitoring of the run parameters. | ||
Its main feature is a web page invoked through any web browser accessing the Midas experimental URL at a defined port (see [[#Usage|Usage]]). | Its main feature is a web page invoked through any web browser accessing the Midas experimental URL at a defined port (see [[#Usage|Usage]]). | ||
Line 63: | Line 76: | ||
** link to the logger configuration (if present) for the data recording. | ** link to the logger configuration (if present) for the data recording. | ||
** link to the possible secondary logging configuration parameters (if present). | ** link to the possible secondary logging configuration parameters (if present). | ||
[[Category:Utilities]] | |||
[[Category:mhttpd]] |
Revision as of 15:21, 16 July 2014
Links
Purpose
The mhttpd utility runs the MIDAS Web Server which allows the user to communicate with an experiment using any web browser. It is used primarily for run control.
Arguments
-p port : port number e.g. 8081 (no default) [-h hostname ] : see Common Parameters to MIDAS Utilities [-e experiment] : see Common Parameters to MIDAS Utilities [-v] : display verbose HTTP communication [-D] : starts program as a daemon [-E] : only display ELog system [-H] : only display history plots [-a hostname] : only allow access for specific host(s). Several [-a Hostname] statements might be given [-help] : display usage information
Usage
The TCP/IP port number is required as an argument in order to listen to the web-based request.
e.g. if mhttpd is started on IP host machine "myhost" on port 8081 as follows
mhttpd -p 8081 -D
access to the Midas status page can be obtained by pointing a web browser to
http://myhost.mydomain:8081
- Note
If multiple experiments run on the same host, a web server for each experiment must be started on a different port, e.g.
mhttpd -e expt1 -p 8081 -D mhttpd -e expt2 -p 8082 -D
Features
mhttpd provides a means for run control including monitoring of the run parameters. Its main feature is a web page invoked through any web browser accessing the Midas experimental URL at a defined port (see Usage).
The contents of this Midas status page is composed with minimal information relative to the experiment. It contains a collection of buttons and links to other pages to further describe and control the configuration of the experiment.
- Minimal display (main web page)
- Experiment name, time & date, page refresh rate
- Standard Buttons (see below)
- User defined buttons
- run comments and condition display section (if enabled)
- Equipment list with current running condition, number of event received, event rate, data rate for each equipment.
- Data logging statistics (number of event recorded, data size recorder, compression factor, usage storage level) if enabled.
- Secondary Data logging (data mover) with statistics if enabled.
- Single line of the most recent Midas message.
- Table of the current applications connected to this experiment.
- Buttons
- Transition the state of the run (stopped/running/paused), allows user running condition parameters to be entered at the start state (see Edit-on-start Parameters).
- Access to the full Online Database for data display and/or data content modification.
- Display the Midas Messages. These messages are generated by the Midas system as well as the user using cm_msg() functions.
- Access to ELOG" site. "Short-cut" switch to the predefined "electronic logbook".
- Access to the Alarms section for monitoring the different type of alarms (evaluated, programs, internals, periodic).
- Access to the Program section for a status or interaction with the current running applications part of the Midas experiment.
- Access to the History for graphical data representation of any ODB variables and acquired data.
- Access to the Midas Slow Control Bus devices MSCB connected to this experiment.
- Access to the run Sequencer control/monitoring page for interactive loading/saving/running of a run sequence based on any ODB parameters.
- Short-cut to the Midas Help documentation resource.
- Links
- links to all the listed equipments invoking a dedicated page for the display and possible control of the equipment parameters.
- link to the logger configuration (if present) for the data recording.
- link to the possible secondary logging configuration parameters (if present).