Back Midas Rome Roody Rootana
  Midas DAQ System  Not logged in ELOG logo
Entry  06 Oct 2019, Nik Berger, Bug Report, History data size mismatch 
    Reply  06 Oct 2019, Stefan Ritt, Bug Report, History data size mismatch 
    Reply  10 Oct 2019, Konstantin Olchanski, Bug Report, History data size mismatch 
    Reply  10 Oct 2019, Nik Berger, Bug Report, History data size mismatch 
       Reply  10 Oct 2019, Stefan Ritt, Bug Report, History data size mismatch 
Message ID: 1719     Entry time: 06 Oct 2019     Reply to this: 1720   1721   1722
Author: Nik Berger 
Topic: Bug Report 
Subject: History data size mismatch 
Logging a list of variables to the history via links in the history ODB subtree,
we get messages as follows at every run start:

19:43:24.009 2019/10/06 [Logger,ERROR] [history_schema.cxx:2676:hs_write_event,ERROR] Event 'System' data size mismatch: expected 412 bytes, got 416 bytes

19:43:24.008 2019/10/06 [Logger,ERROR] [history_schema.cxx:2676:hs_write_event,ERROR] Event 'System' data size mismatch: expected 412 bytes, got 416 bytes

19:43:23.850 2019/10/06 [Logger,ERROR] [history_schema.cxx:455:hs_write_event,ERROR] Event 'System' data size mismatch count: 25, expected 412 bytes, hs_write_event() called with as much as 416 bytes

19:43:23.850 2019/10/06 [Logger,ERROR] [history_schema.cxx:455:hs_write_event,ERROR] Event 'System' data size mismatch count: 25, expected 412 bytes, hs_write_event() called with as much as 416 bytes

The history calculates the size of a record from the size of the individual variables, (history_schema.cxx, L2666 ff), whereas the ODB delivers the data aligned/padded to the size of the largest value in the record.
In our history, a long list of doubles (64 Bit) fas followed by three floats (32 bit), leading to a padded response from the ODB, 4 byte longer than the history expects.
Quick fix: Add another 32 bit dummy variable to the history. Gets rid of the error messages...
Should probably be fixed at a deeper level...