Entry  10 Aug 2020, Ivo Schulthess, Bug Report, data missing in runXXXXXX.mid 
    Reply  10 Aug 2020, Stefan Ritt, Bug Report, data missing in runXXXXXX.mid 
       Reply  10 Aug 2020, Ivo Schulthess, Bug Report, data missing in runXXXXXX.mid 
          Reply  10 Aug 2020, Stefan Ritt, Bug Report, data missing in runXXXXXX.mid 
             Reply  10 Aug 2020, Ivo Schulthess, Bug Report, data missing in runXXXXXX.mid 
                Reply  10 Aug 2020, Stefan Ritt, Bug Report, data missing in runXXXXXX.mid 
                   Reply  10 Aug 2020, Ivo Schulthess, Bug Report, data missing in runXXXXXX.mid 
                      Reply  10 Aug 2020, Stefan Ritt, Bug Report, data missing in runXXXXXX.mid 
                         Reply  10 Aug 2020, Ivo Schulthess, Bug Report, data missing in runXXXXXX.mid 
                            Reply  10 Aug 2020, Stefan Ritt, Bug Report, data missing in runXXXXXX.mid 
                               Reply  11 Aug 2020, Konstantin Olchanski, Bug Report, data missing in runXXXXXX.mid 
                                  Reply  11 Aug 2020, Ivo Schulthess, Bug Report, data missing in runXXXXXX.mid 
                                     Reply  24 Mar 2022, Konstantin Olchanski, Bug Report, data missing in runXXXXXX.mid 
                                        Reply  24 Mar 2022, Stefan Ritt, Bug Report, data missing in runXXXXXX.mid 
                                           Reply  24 Mar 2022, Konstantin Olchanski, Bug Report, data missing in runXXXXXX.mid 
Message ID: 1975     Entry time: 10 Aug 2020     In reply to: 1973     Reply to this: 1978
Author: Ivo Schulthess 
Topic: Bug Report 
Subject: data missing in runXXXXXX.mid 
> Have you tried longer files? Maybe a few 100 MB or so. Maybe a buffer is not flushed correctly at the end of a run.

Yes, I did. This 7 KB of the data bank is about the limit. If we go only 1 KB higher it seems that we save all data. In 
our specific case, this is the number of time bins (256 pixels with 7 time bins results in data loss, with 8 time bins it 
seems to be okay, data type is DWORD). 

Of course, a workaround for us is to save at least 8 time bins and throw 7 of them away later on. Nevertheless, since we 
are only in the commissioning phase now this is okay, I would just like to avoid data loss in the data taking phase of the 
experiment so knowing where the problem origins could help. 

I did another test with another FE running that produces a lot of data. The behavior is the same though. If the bank size 
is less than about 8 KB, the bank is not saved anymore. But probably this is anyway the expected behavior since it is a 
different FE that produces the data. 

So if it is coming from the buffer, is there something I could change to test or solve the problem?

Best, Ivo