Message ID: 2148     Entry time: 12 Apr 2021     In reply to: 2147     Reply to this: 2149
Author: Ben Smith 
Topic: Forum 
Subject: Client gets immediately removed when using a script button. 
I think it would be useful to find the minimal example that exhibits this behaviour.

What happens if your logic controller code is simply the 17 lines below? What happens if you create another script button that only starts the logic controller, not any of the other programs? etc. Gradually re-add features until you hit the problem (or scream in horror if it breaks with 17 lines of C++ and a 1 line shell script).



#include "midas.h"
#include "stdio.h"

int main() {
   cm_connect_experiment("", "", "logic_controller", NULL);

   do {
     int status = cm_yield(100);
     printf("cm_yield returned %d\n", status);
     if (status == SS_ABORT || status == RPC_SHUTDOWN)
       break;
   } while (!ss_kbhit());

   cm_disconnect_experiment();

   return 0;
}