Entry  12 Apr 2021, Isaac Labrie Boulay, Forum, Client gets immediately removed when using a script button. logicCtrl.cppstart_daq.PNG
    Reply  12 Apr 2021, Ben Smith, Forum, Client gets immediately removed when using a script button. 
       Reply  12 Apr 2021, Isaac Labrie Boulay, Forum, Client gets immediately removed when using a script button. debug_logic_controller.txt
          Reply  12 Apr 2021, Ben Smith, Forum, Client gets immediately removed when using a script button. 
             Reply  13 Apr 2021, Isaac Labrie Boulay, Forum, Client gets immediately removed when using a script button. 
                Reply  13 Apr 2021, Stefan Ritt, Forum, Client gets immediately removed when using a script button. 
Message ID: 2149     Entry time: 13 Apr 2021     In reply to: 2148     Reply to this: 2151
Author: Isaac Labrie Boulay 
Topic: Forum 
Subject: Client gets immediately removed when using a script button. 
> I think it would be useful to find the minimal example that exhibits this behaviour.
> 
> What happens if your logic controller code is simply the 17 lines below? What happens if you create another script button that only starts the logic controller, not any of the other programs? etc. Gradually re-add features until you hit the problem (or scream in horror if it breaks with 17 lines of C++ and a 1 line shell script).
> 

Hi Ben,

I have followed your suggestions and the program still stops immediately. My status as returned from "cm_yield(100)" is always 412 (SS_TIMEOUT) which is fine. 
The issue is that, when run with the script button, the do-wile loop stops immediately because the !ss_kbhit() always evaluates to FALSE.

My temporary solution has been to let the loop run forever :)

Let me know what think. Thanks again!

Isaac

> 
> 
> #include "midas.h"
> #include "stdio.h"
> 
> int main() {
>    cm_connect_experiment("", "", "logic_controller", NULL);
> 
>    do {
>      int status = cm_yield(100);
>      printf("cm_yield returned %d\n", status);
>      if (status == SS_ABORT || status == RPC_SHUTDOWN)
>        break;
>    } while (!ss_kbhit());
> 
>    cm_disconnect_experiment();
> 
>    return 0;
> }